Anibal de la Piedad-Beneitez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Anibal de la Piedad-Beneitez has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Antonio Mercado Cabrera
Instituto Nacional de Investigaciones Nucleares
11 shared publications - Rosendo Peña Eguiluz
Instituto Nacional de Investigaciones Nucleares
11 shared publications - Raul Valencia Alvarado
Instituto Nacional de Investigaciones Nucleares
9 shared publications - Régulo López-Callejas
Plasma Physics Laboratory, National Institute of Nuclear Research, Carretera México Toluca S/N, Ocoyoacac 52750, Estado de México, Mexico
8 shared publications - Benjamin Gonzalo Rodriguez-Mendez
Plasma Physics Laboratory, National Institute of Nuclear Research, Carretera México Toluca S/N, Ocoyoacac 52750, Estado de México, Mexico
7 shared publications A.E. Muñoz-Castro
6 shared publications
Latest Publications
- Open Access
- 29 July 2016
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 67, 06075
Sequential Processes to Produce N-TiO2Films Through Rf Plasmas
- 29 July 2016
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 67, 06075
Open AccessSequential Processes to Produce N-TiO2Films Through Rf Plasmas
- 1 August 2013
- Published by Elsevier in Surface and Coatings Technology
- Vol. 229, 22-25
Biological-standard PIII surface conditioning of CpTi instruments and prostheses
- 1 August 2013
- Published by Elsevier in Surface and Coatings Technology
- Vol. 229, 22-25
Biological-standard PIII surface conditioning of CpTi instruments and prostheses
- 2 December 2011
- Published by EDP Sciences in The European Physical Journal Applied Physics
- Vol. 57 (1) , 10802
DBD reactor instrumentation for NOxdegradation
The design and construction of an instrumentation for NOX degradation in a dielectric-barrier discharge reactor (DBDR) is presented. This is endowed with a parallel plane electrode glass-glass (GG) circular geometry configuration. A solid-state multi-cellular power supply was produced in order to generate the plasma discharge. The power supply is based on a full-bridge voltage inverter commanded by three 4.33 kHz square-wave signals. Thus, the output converter signal is filtered by a resonant LC circuit, providing a 13 kHz sine wave to the DBDR. Initial results showing high removal efficiencies of about 97% have been obtained by means of this instrumentation.
- 2 December 2011
- Published by EDP Sciences in The European Physical Journal Applied Physics
- Vol. 57 (1) , 10802
DBD reactor instrumentation for NOxdegradation
The design and construction of an instrumentation for NOX degradation in a dielectric-barrier discharge reactor (DBDR) is presented. This is endowed with a parallel plane electrode glass-glass (GG) circular geometry configuration. A solid-state multi-cellular power supply was produced in order to generate the plasma discharge. The power supply is based on a full-bridge voltage inverter commanded by three 4.33 kHz square-wave signals. Thus, the output converter signal is filtered by a resonant LC circuit, providing a 13 kHz sine wave to the DBDR. Initial results showing high removal efficiencies of about 97% have been obtained by means of this instrumentation.
- Open Access
- 1 June 2009
- Published by FapUNIFESP (SciELO) in Brazilian Journal of Physics
- Vol. 39 (2) , 264-269
Three cell flying capacitor inverter for dielectric barrier discharge plasma applications
- 1 June 2009
- Published by FapUNIFESP (SciELO) in Brazilian Journal of Physics
- Vol. 39 (2) , 264-269
Open AccessThree cell flying capacitor inverter for dielectric barrier discharge plasma applications
- 8 February 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 36 (1) , 185-191
Instrumentation for Pulsed Corona Discharge Generation Applied to Water
In this paper, we present a model (which is structured as an equivalent electric circuit whose elements are identified and deducted from the nature of the medium, the ionization and expansion process of the streamers that convey the prebreakdown current, and the energy associated to the electric breakdown in water) and a simulation of a pulsed corona discharge (PCD). Considering this, a coaxial reactor and an inexpensive and compact high-voltage pulsed-power supply (PPS) system were designed and constructed with the purpose of carrying out the PCD experimentally. The simulation results enable the prediction of the behavior of the discharge. The coaxial reactor is constituted by a cylindrical chamber and a straight central rod. The PPS operates within the 100-2000-Hz repetition rate and 0-30-kV amplitude ranges. All the system has been tested, and the first electrical results, voltage, and current waveforms, are presented.
- 8 February 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 36 (1) , 185-191
Instrumentation for Pulsed Corona Discharge Generation Applied to Water
In this paper, we present a model (which is structured as an equivalent electric circuit whose elements are identified and deducted from the nature of the medium, the ionization and expansion process of the streamers that convey the prebreakdown current, and the energy associated to the electric breakdown in water) and a simulation of a pulsed corona discharge (PCD). Considering this, a coaxial reactor and an inexpensive and compact high-voltage pulsed-power supply (PPS) system were designed and constructed with the purpose of carrying out the PCD experimentally. The simulation results enable the prediction of the behavior of the discharge. The coaxial reactor is constituted by a cylindrical chamber and a straight central rod. The PPS operates within the 100-2000-Hz repetition rate and 0-30-kV amplitude ranges. All the system has been tested, and the first electrical results, voltage, and current waveforms, are presented.
- 1 January 2008
- Published by Sycamore Global Publications in Journal of Advanced Oxidation Technologies
- Vol. 11 (1)
AOP in Water by Means of a DBD Conducted in a Coaxial Reactor
The design and construction of a system consisting of a dielectric barrier cell and the electronic instrumentation intended to generate pulsed discharges at atmospheric pressure in water is showed in this paper. Also, the experimental results from the developed advanced oxidation processes (AOPs) are presented. Demineralised water with a conductivity of 5 μS/cm was used in all tests and a non-thermal plasma is produced between two concentric electrodes in a coaxial configuration by applying high voltage pulses which amplitude can be adjusted from 0 to 30 kV. The propagation of the streamers was characterized by means of the obtained waveforms of voltage and current. The concentration of the ozone generated by the discharges was monitored allowing, in this way, to carry out an analysis of the AOPs, and optic spectroscopy was used to study the discharge parameters involved in such a process.
- 1 January 2008
- Published by Sycamore Global Publications in Journal of Advanced Oxidation Technologies
- Vol. 11 (1)
AOP in Water by Means of a DBD Conducted in a Coaxial Reactor
The design and construction of a system consisting of a dielectric barrier cell and the electronic instrumentation intended to generate pulsed discharges at atmospheric pressure in water is showed in this paper. Also, the experimental results from the developed advanced oxidation processes (AOPs) are presented. Demineralised water with a conductivity of 5 μS/cm was used in all tests and a non-thermal plasma is produced between two concentric electrodes in a coaxial configuration by applying high voltage pulses which amplitude can be adjusted from 0 to 30 kV. The propagation of the streamers was characterized by means of the obtained waveforms of voltage and current. The concentration of the ozone generated by the discharges was monitored allowing, in this way, to carry out an analysis of the AOPs, and optic spectroscopy was used to study the discharge parameters involved in such a process.