Futoshi Kobayashi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Futoshi Kobayashi has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Hiroyuki Nakamoto
Graduate School of System Informatics, Kobe University, Kobe, Japan
16 shared publications - Fumio Kojima
Kobe University
14 shared publications Hidenori Shirasawa
The Advanced Materials Processing Institute Kinki Japan, Amagasaki, Japan
11 shared publicationsNobuaki Imamura
Hiroshima International University, Kure, Japan
11 shared publicationsTadashi Maeda
MAEDA PRECISION MANIFUCTURING
8 shared publicationsKazuhiro Sasabe
The Kansai Electric Power Co., Inc
4 shared publications
Latest Publications
- Open Access
A Magnetic Food Texture Sensor and Comparison of the Measurement Data of Chicken Nuggets
Food texture is one of the important quality indicators in foodstuffs, along with appearance and flavor, contributing to taste and odor. This study proposes a novel magnetic food texture sensor that corresponds to the tactile sensory capacity of the human tooth. The sensor primarily consists of a probe, linear slider, spring, and circuit board. The probe has a cylindrical shape and includes a permanent magnet. Both sides of the spring are fixed to the probe and circuit board. The linear slider enables the smooth, single-axis motion of the probe during food compression. Two magnetoresistive elements and one inductor on the circuit board measured the probe’s motion. A measurement system then translates the measurement data collected by the magnetoresistive elements into compression force by means of a calibration equation. Fundamental experiments were performed to evaluate the range, resolution, repetitive durability of force, and differences in the frequency responses. Furthermore, the sensor was used to measure seven types of chicken nuggets with different coatings. The difference between the force and vibration measurement data is revealed on the basis of the discrimination rate of the nuggets.
Open AccessA Magnetic Food Texture Sensor and Comparison of the Measurement Data of Chicken Nuggets
Food texture is one of the important quality indicators in foodstuffs, along with appearance and flavor, contributing to taste and odor. This study proposes a novel magnetic food texture sensor that corresponds to the tactile sensory capacity of the human tooth. The sensor primarily consists of a probe, linear slider, spring, and circuit board. The probe has a cylindrical shape and includes a permanent magnet. Both sides of the spring are fixed to the probe and circuit board. The linear slider enables the smooth, single-axis motion of the probe during food compression. Two magnetoresistive elements and one inductor on the circuit board measured the probe’s motion. A measurement system then translates the measurement data collected by the magnetoresistive elements into compression force by means of a calibration equation. Fundamental experiments were performed to evaluate the range, resolution, repetitive durability of force, and differences in the frequency responses. Furthermore, the sensor was used to measure seven types of chicken nuggets with different coatings. The difference between the force and vibration measurement data is revealed on the basis of the discrimination rate of the nuggets.
- 28 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (13) , 14352-14359
Wearable Band-Shaped Device and Detection Algorithm for Laryngeal Elevation in Mendelsohn Maneuver
Aspiration pneumonia is a serious condition in the elderly. To strengthen the muscles required for swallowing, patients can train using the Mendelsohn maneuver, wherein they maintain their larynx at the top of the laryngeal elevation during swallowing. This study describes a wearable device to detect the onset and offset times of the laryngeal elevation for a biofeedback system to support this training. The biofeedback system consists of a band-shaped device with stretchable strain sensors. The strain sensors measure the change of circumferential length of the neck. An algorithm detects the onset and offset times of the laryngeal elevation based on the absolute first-order difference of the measured data and distance between the measured data and template data by pattern matching. The algorithm detected the onset and offset times of 53 out of 54 data sets from elderly participants. Cluster analysis separated the data into two groups. For both groups, the mean absolute error of the interval time was within 1 s when compared with the time recorded by a speech-language-hearing therapist. We believe that this biofeedback system for the Mendelsohn maneuver tolerates the 1 s delay. The wearable device is soft, lightweight, and easy for a patient to use alone. The efficacy of the device for the strengthening of muscles must be verified in a clinical study.
- 28 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (13) , 14352-14359
Wearable Band-Shaped Device and Detection Algorithm for Laryngeal Elevation in Mendelsohn Maneuver
Aspiration pneumonia is a serious condition in the elderly. To strengthen the muscles required for swallowing, patients can train using the Mendelsohn maneuver, wherein they maintain their larynx at the top of the laryngeal elevation during swallowing. This study describes a wearable device to detect the onset and offset times of the laryngeal elevation for a biofeedback system to support this training. The biofeedback system consists of a band-shaped device with stretchable strain sensors. The strain sensors measure the change of circumferential length of the neck. An algorithm detects the onset and offset times of the laryngeal elevation based on the absolute first-order difference of the measured data and distance between the measured data and template data by pattern matching. The algorithm detected the onset and offset times of 53 out of 54 data sets from elderly participants. Cluster analysis separated the data into two groups. For both groups, the mean absolute error of the interval time was within 1 s when compared with the time recorded by a speech-language-hearing therapist. We believe that this biofeedback system for the Mendelsohn maneuver tolerates the 1 s delay. The wearable device is soft, lightweight, and easy for a patient to use alone. The efficacy of the device for the strengthening of muscles must be verified in a clinical study.
- 1 January 2017
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2017, 2P1-C10
POD Evaluation of Motion Capturing Systems for Robot Teleoperation
Tele-operated robotic systems have been applied in extreme environment. In order to operate delicate tasks, many humanoid robots have been developed. Motion capturing systems are often used so as to tele-operate those robots. However, it is difficult for individual motion capturing system to measure precise joint angles of a human arm. Therefore, we integrate two motion capturing systems. Here, it is important how two motion capturing systems are integrated. In this paper, we evaluate the reliability of each motion capturing system. The probability of detection (POD) is applied to evaluate the reliability of two systems. By using POD, it is possible to evaluate the influence caused by measurement environment and camera arrangement etc. Consequently, based on the POD evaluation, the tendency of the reliability of two motion capturing systems were confirmed.
- 1 January 2017
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2017, 2P1-C10
POD Evaluation of Motion Capturing Systems for Robot Teleoperation
Tele-operated robotic systems have been applied in extreme environment. In order to operate delicate tasks, many humanoid robots have been developed. Motion capturing systems are often used so as to tele-operate those robots. However, it is difficult for individual motion capturing system to measure precise joint angles of a human arm. Therefore, we integrate two motion capturing systems. Here, it is important how two motion capturing systems are integrated. In this paper, we evaluate the reliability of each motion capturing system. The probability of detection (POD) is applied to evaluate the reliability of two systems. By using POD, it is possible to evaluate the influence caused by measurement environment and camera arrangement etc. Consequently, based on the POD evaluation, the tendency of the reliability of two motion capturing systems were confirmed.
- 3 August 2016
- Published by Springer Nature
- p. 479-487
Visualization of Remote Taskspace for Hand/Arm Robot Teleoperation
- 3 August 2016
- Published by Springer Nature
- p. 479-487
Visualization of Remote Taskspace for Hand/Arm Robot Teleoperation
- 1 August 2016
- Published by SAGE Publications in International Journal of Applied Electromagnetics and Mechanics
- Vol. 52 (3-4) , 1629-1636
Human motion caption with vision and inertial sensors for hand/arm robot teleoperation
The multi-fingered robot hand has much attention in various fields. Many robot hands have been proposed so far. A teleoperation system for the hand/arm robot allows intuitive manipulation of the hand/arm robot. This paper deals with a motion capture system for controlling the hand/arm robot remotely. Here, we use vision and inertial sensors simultaneously in order to detect the position and the posture of an operator's arm and hand.
- 1 August 2016
- Published by SAGE Publications in International Journal of Applied Electromagnetics and Mechanics
- Vol. 52 (3-4) , 1629-1636
Human motion caption with vision and inertial sensors for hand/arm robot teleoperation
The multi-fingered robot hand has much attention in various fields. Many robot hands have been proposed so far. A teleoperation system for the hand/arm robot allows intuitive manipulation of the hand/arm robot. This paper deals with a motion capture system for controlling the hand/arm robot remotely. Here, we use vision and inertial sensors simultaneously in order to detect the position and the posture of an operator's arm and hand.
- 1 January 2016
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2016, 2A2-04a2
Development of Vision Feedback System with AR for Robot Hand Teleoperation
- 1 January 2016
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2016, 2A2-04a2
Development of Vision Feedback System with AR for Robot Hand Teleoperation
- 1 January 2014
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2014, _3P1-R05_1
3P1-R05 Decision of Grasping Posture Considering Object Slippage with Multi-fingered Robot Hand(Robot Hand Mechanism and Grasping Strategy (1))
- 1 January 2014
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2014, _3P1-R05_1
3P1-R05 Decision of Grasping Posture Considering Object Slippage with Multi-fingered Robot Hand(Robot Hand Mechanism and Grasping Strategy (1))
- 1 January 2013
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2013, _1A1-J06_1
1A1-J06 Teleoperation for Hand/Arm Robot by Inertial Motion Capture(Robot Hand Mechanism and Grasping Strategy (1))
The multi-fingered robot hand has much attention in various fields. Many Robot hands have been proposed so far. A teleoperation system for the hand/arm robot allows intuitive manipulation of the hand/arm robot. Therefore, this paper deals with a motion capture system for controlling the hand/arm robot remotely. Here, we use inertial measurement units in order to detect the joint angle of an operator's hand and arm.
- 1 January 2013
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2013, _1A1-J06_1
1A1-J06 Teleoperation for Hand/Arm Robot by Inertial Motion Capture(Robot Hand Mechanism and Grasping Strategy (1))
The multi-fingered robot hand has much attention in various fields. Many Robot hands have been proposed so far. A teleoperation system for the hand/arm robot allows intuitive manipulation of the hand/arm robot. Therefore, this paper deals with a motion capture system for controlling the hand/arm robot remotely. Here, we use inertial measurement units in order to detect the joint angle of an operator's hand and arm.
- 1 January 2013
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2013, _1A1-J07_1
1A1-J07 Handover Motion by Hand/Arm Robot based on Hand Posture(Robot Hand Mechanism and Grasping Strategy (1))
This paper deals with a handover motion for the hand/arm robot. Handing over objects to humans is an important motion for service robots. The robot has to change a trajectory for handover without disturbing human's works. Therefore, we propose a handover motion control for the hand/arm robot according to the hand posture of humans. The robot estimates the hand posture with a motion sensing input device Kinect and moves upward from the palm of human's hand.
- 1 January 2013
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2013, _1A1-J07_1
1A1-J07 Handover Motion by Hand/Arm Robot based on Hand Posture(Robot Hand Mechanism and Grasping Strategy (1))
This paper deals with a handover motion for the hand/arm robot. Handing over objects to humans is an important motion for service robots. The robot has to change a trajectory for handover without disturbing human's works. Therefore, we propose a handover motion control for the hand/arm robot according to the hand posture of humans. The robot estimates the hand posture with a motion sensing input device Kinect and moves upward from the palm of human's hand.
- 1 February 2012
- Published by SAGE Publications in International Journal of Applied Electromagnetics and Mechanics
- Vol. 39 (1-4) , 1047-1054
Slip detection with multi-axis force/torque sensor in universal robot hand
A humanoid robot hand receives much attention in various fields. We have developed the universal robot hand with the multi-axis force/torque sensors. In order to manipulate an object by the robot hand without dropping the object, it is important to detect a slip between the object and the robot finger. Therefore, we propose a slip detection method with the multi-axis force/torque sensor and an anti-slip control method based on the slip detection. The effectiveness of the proposed slip detection and the anti-slip control is verified through some experiments with the universal robot hand.
- 1 February 2012
- Published by SAGE Publications in International Journal of Applied Electromagnetics and Mechanics
- Vol. 39 (1-4) , 1047-1054
Slip detection with multi-axis force/torque sensor in universal robot hand
A humanoid robot hand receives much attention in various fields. We have developed the universal robot hand with the multi-axis force/torque sensors. In order to manipulate an object by the robot hand without dropping the object, it is important to detect a slip between the object and the robot finger. Therefore, we propose a slip detection method with the multi-axis force/torque sensor and an anti-slip control method based on the slip detection. The effectiveness of the proposed slip detection and the anti-slip control is verified through some experiments with the universal robot hand.