Aurika Janulyte
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Aurika Janulyte has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Jacques Andre
Aix Marseille Universite
3 shared publicationsMichel Carette
Université de Provence, Laboratoire Chimie Provence - UMR CNRS 6264, Equipe Instrumentation et Réactivité Atmosphérique, Centre de Saint Jérôme Avenue Escadrille-Normandie-Niemen, 13397 Marseille, Cedex 20, France
2 shared publicationsStephen Taylor
Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool, UK
2 shared publicationsYves Zerega
Aix-Marseille Université, LISA EA 4672, Campus Etoile - Service 461, Avenue Escadrille Normandie Niémen, 13397, Marseille Cedex 20, France
2 shared publicationsBoris Brkic
Q-Technologies Ltd, 100 Childwall Road, Liverpool, L15 6UX, UK
1 shared publication- Boris Brkić
BioSense Institute, University of Novi Sad, Dr Zorana Đinđića 1, 21000 Novi Sad, Serbia
1 shared publication
Latest Publications
- 11 June 2019
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 34 (8) , 1672-1682
Accurate modelling of small-scale linear ion trap operating mode using He buffer gas to improve sensitivity and resolution for in-the-field mass spectrometry
Spectral peak separations of 4 m/z were previously measured using a small-scale mass spectrometer. In this paper the use of He buffer gas during mass analysis was investigated in order to obtain better peak separations (1 m/z) and to optimize the design prior to construction of a new linear ion trap (LIT) device with a novel electrode arrangement and operating mode. Ion/neutral collisions were simulated during LIT operation with an event driven statistical collision treatment tool using 3D electric field boundary element modelling software. Using He buffer gas during the LIT cooling step and assuming a collision-free isolation step during the LIT operating mode, 1 m/z separation can be obtained with also an increased instrument sensitivity. This requires adaptation of both the LIT operating mode and the LIT device configuration. These performance improvements come at the expense of an increase in the analysis duration time which however remains acceptable.
- 11 June 2019
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 34 (8) , 1672-1682
Accurate modelling of small-scale linear ion trap operating mode using He buffer gas to improve sensitivity and resolution for in-the-field mass spectrometry
Spectral peak separations of 4 m/z were previously measured using a small-scale mass spectrometer. In this paper the use of He buffer gas during mass analysis was investigated in order to obtain better peak separations (1 m/z) and to optimize the design prior to construction of a new linear ion trap (LIT) device with a novel electrode arrangement and operating mode. Ion/neutral collisions were simulated during LIT operation with an event driven statistical collision treatment tool using 3D electric field boundary element modelling software. Using He buffer gas during the LIT cooling step and assuming a collision-free isolation step during the LIT operating mode, 1 m/z separation can be obtained with also an increased instrument sensitivity. This requires adaptation of both the LIT operating mode and the LIT device configuration. These performance improvements come at the expense of an increase in the analysis duration time which however remains acceptable.
- 3 October 2016
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 30 (22) , 2407-2415
Performance assessment of a portable mass spectrometer using a linear ion trap operated in non‐scanning mode
Rationale: The desire for mass spectrometer portability provides the motivation for simpler, lighter electronics to deliver switched potentials applied to the electrodes of the linear ion trap operated in non‐scanning mode. Using a novel method of modelling and theoretical analysis, we simulate the mass analyser performance under these unfavourable operating conditions. Methods: The electrical fields are simulated using the Charge Particle Optics software which employs the boundary element method. The ion trajectories are computed from the ion cage of the EI source to the interior of the trap where the ions are confined. The spatial/temporal ion distributions during injection are calculated from the individual ion trajectories computed with constant time‐steps. Due to geometric non‐linearities, β y = 0 lines close to the apex of the stability diagram have been computed for different initial positions with zero initial velocities in order to define the acceptable maximum axial extension. Results: The DC potential well depth has been estimated at about 15 eV from the axial velocity distribution, and the minimum time of ion injection at 120 μs from the temporal ion distribution. To ensure a mass separation of one unit and the confinement of the whole of the injected ions, buffer gas cooling is necessary to reduce the trajectory excursion amplitudes to 0.1 and 15 mm in the radial and axial directions, respectively. Conclusions: The portable mass spectrometer is predicted to achieve a mass resolution of better than one mass unit providing that helium buffer gas is used. An additional cooling sequence has to be added prior to moving the operating point toward the apex. Copyright © 2016 John Wiley & Sons, Ltd.
- 3 October 2016
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 30 (22) , 2407-2415
Performance assessment of a portable mass spectrometer using a linear ion trap operated in non‐scanning mode
Rationale: The desire for mass spectrometer portability provides the motivation for simpler, lighter electronics to deliver switched potentials applied to the electrodes of the linear ion trap operated in non‐scanning mode. Using a novel method of modelling and theoretical analysis, we simulate the mass analyser performance under these unfavourable operating conditions. Methods: The electrical fields are simulated using the Charge Particle Optics software which employs the boundary element method. The ion trajectories are computed from the ion cage of the EI source to the interior of the trap where the ions are confined. The spatial/temporal ion distributions during injection are calculated from the individual ion trajectories computed with constant time‐steps. Due to geometric non‐linearities, β y = 0 lines close to the apex of the stability diagram have been computed for different initial positions with zero initial velocities in order to define the acceptable maximum axial extension. Results: The DC potential well depth has been estimated at about 15 eV from the axial velocity distribution, and the minimum time of ion injection at 120 μs from the temporal ion distribution. To ensure a mass separation of one unit and the confinement of the whole of the injected ions, buffer gas cooling is necessary to reduce the trajectory excursion amplitudes to 0.1 and 15 mm in the radial and axial directions, respectively. Conclusions: The portable mass spectrometer is predicted to achieve a mass resolution of better than one mass unit providing that helium buffer gas is used. An additional cooling sequence has to be added prior to moving the operating point toward the apex. Copyright © 2016 John Wiley & Sons, Ltd.
- 21 January 2011
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 46 (2) , 136-143
Sensitivity and amplitude calibration of a Fourier transform 3D quadrupole ion trap mass spectrometer
- 21 January 2011
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 46 (2) , 136-143
Sensitivity and amplitude calibration of a Fourier transform 3D quadrupole ion trap mass spectrometer