DRDavid E. Reese

David E. Reese

*This is an algorithmically generated author record based on publicly available information.

David E. Reese has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Noninvasive Blood-based Combinatorial Proteomic Biomarker Assay to Detect Breast Cancer in Women Under the Age of 50 Years

    by Ana P. Lourenco, Kasey L. Benson, Meredith C. Henderson, Michael Silver, Elias Letsios, Quynh Tran, Kelly J. Gordon, Sherri Borman, Christa Corn, Rao Mulpuri, et al.


  • Open Access

    Integration of Serum Protein Biomarker and Tumor Associated Autoantibody Expression Data Increases the Ability of a Blood-Based Proteomic Assay to Identify Breast Cancer

    by Meredith C. Henderson, Alan B. Hollingsworth, Kelly Gordon, Michael Silver, Rao Mulpuri, Elias Letsios, David E. Reese

    Despite significant advances in breast imaging, the ability to accurately detect Breast Cancer (BC) remains a challenge. With the discovery of key biomarkers and protein signatures for BC, proteomic technologies are currently poised to serve as an ideal diagnostic adjunct to imaging. Research studies have shown that breast tumors are associated with systemic changes in levels of both serum protein biomarkers (SPB) and tumor associated autoantibodies (TAAb). However, the independent contribution of SPB and TAAb expression data for identifying BC relative to a combinatorial SPB and TAAb approach has not been fully investigated. This study evaluates these contributions using a retrospective cohort of pre-biopsy serum samples with known clinical outcomes collected from a single site, thus minimizing potential site-to-site variation and enabling direct assessment of SPB and TAAb contributions to identify BC. All serum samples (n = 210) were collected prior to biopsy. These specimens were obtained from 18 participants with no evidence of breast disease (ND), 92 participants diagnosed with Benign Breast Disease (BBD) and 100 participants diagnosed with BC, including DCIS. All BBD and BC diagnoses were based on pathology results from biopsy. Statistical models were developed to differentiate BC from non-BC (i.e., BBD and ND) using expression data from SPB alone, TAAb alone, and a combination of SPB and TAAb. When SPB data was independently used for modeling, clinical sensitivity and specificity for detection of BC were 74.7% and 77.0%, respectively. When TAAb data was independently used, clinical sensitivity and specificity for detection of BC were 72.2% and 70.8%, respectively. When modeling integrated data from both SPB and TAAb, the clinical sensitivity and specificity for detection of BC improved to 81.0% and 78.8%, respectively. These data demonstrate the benefit of the integration of SPB and TAAb data and strongly support the further development of combinatorial proteomic approaches for detecting BC.


  • dtectDx Breast: A serum biomarker test for breast cancer detection used in conjunction with traditional mammography screening.

    by Meredith C. Henderson, Keri Sweeten, Sherri Borman, Christa Corn, Lindsey Gordon, David E. Reese

    18 Background: Provista Diagnostics has developed a test that analyzes serum concentrations of 5 protein biomarkers in order to detect breast cancer. The dtectDx Breast test utilizes a proprietary algorithm that has been described previously (Weber et al. 2010). In this study, it was noted that the algorithm performs best in women under age 50. The aim of this study was to evaluate the performance characteristics of dtectDx Breast in women under age 50 in a commercial setting and compare the results with data from the previous clinical study. Methods: The dtectDx Breast test measures the concentrations of IL-8, IL-12, VEGF, CEA, and HGF via ELISA. These data combined with select patient characteristics and Provista’s proprietary algorithm result in a test value that is characterized as normal or elevated. dtectDx Breast test reports issued for women under age 50 were reviewed from a 3-year time period and prescribing physicians were interviewed regarding follow-up care and outcome measures (largely imaging studies, if warranted). Results: Of the 908 patients, 8 samples were rejected based on serum quality. Of the remaining 900 patients, 121 were reported as elevated (12.7%). In 4 cases, these elevated results were confirmed cases of breast cancer. Of these, 2 patients initially showed no screening evidence of cancer, but upon further evaluation (after receipt of dtectDx Breast results) were diagnosed with breast cancer. dtectDx correctly identified DCIS 66% of the time (n=2). Conclusions: These results describe the use of dtectDx Breast in a clinical setting and confirm that the assay behaves similarly to previously published results (Weber et al 2010). While the false-positive rate is higher than predicted (12.7% vs 6.8%), the assay correctly identified 4 of 4 invasive cancers and 2 of 3 DCIS cases. Since two of the invasive cancer cases were originally not detected via standard screening procedures, the assay has demonstrated important clinical utility when used in conjunction with mammography/standard of care. Here we show that, in the commercial patient population, when combined with standard of care, dtectDx Breast improves the detection of breast cancer in women under 50.