Larissa Loureiro Salgueiro Silva
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Larissa Loureiro Salgueiro Silva has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Juacyara Carbonelli Campos
Universidade Federal do Rio de Janeiro, Brazil
4 shared publications - Fabiana Valéria da Fonseca
School of Chemistry, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
3 shared publications Fabiana V. Fonseca
2 shared publicationsAna Maria Rocco
1 shared publication- Ana Maria Rocco
Conductive Materials and Energy Group, Chemical and Biochemical Engineering Processes, School of Chemistry, UFRJ, Universidade Federal do Rio de Janeiro, Centro de Tecnologia, Bloco E,Rio de Janeiro, RJ 21941-909, Brazil
1 shared publication Carolinne Ragazzi Piombini
Inorganic Process Department, School of Chemistry, Federal University of Rio de Janeiro, Rio de Janeiro, RJ, Brazil
1 shared publication
Latest Publications
- 29 November 2021
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part A
- Vol. 56 (14) , 1457-1470
Optimization of ozonation process for organic matter and ecotoxicity removal from landfill leachate by applying rotatable central composite design (RCCD)
Ozonation process was used for leachate treatment from a landfill located in Rio de Janeiro, Brazil. The influence of pH and ozone concentration on COD (Chemical Oxygen Demand), TOC (Total Organic Carbon), Absorbance at 254 nm (ABS254nm), and True color was evaluated through RCCD (Rotatable Central Composite Design) experimental design, resulting in mathematical models that were statistically analyzed in Statistica and Design Expert software. The removals obtained was up to 26.1%, 29.9%, 56.9%, and 97.9% for COD ([COD]0=3,323 mg/L), TOC ([TOC]0=1,275 mg/L), ABS254nm (ABS0=32.2), and True color ([True color]0=3,467 mgPt-Co/L), respectively. Statistical and variance analysis of the experimental data revealed that one quadratic model obtained in Statistica was valid, ABS254nm reduction. However, by applying the Design Expert software, modified models were generated to predict the behavior of all dependent variables. Thus, the optimum point for the best response after ozonation of the landfill leachate was at the highest pH and the lowest ozone dose (9 and 2.2 mgO3/m3, respectively). Toxicity toward Allivibrio fischeri bacteria was abated at the same time that it decreased the impact of the effluent to Danio rerio fish (from 125 UT to 62 UT) on the treated leachate. Graphical Abstract
- 29 November 2021
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part A
- Vol. 56 (14) , 1457-1470
Optimization of ozonation process for organic matter and ecotoxicity removal from landfill leachate by applying rotatable central composite design (RCCD)
Ozonation process was used for leachate treatment from a landfill located in Rio de Janeiro, Brazil. The influence of pH and ozone concentration on COD (Chemical Oxygen Demand), TOC (Total Organic Carbon), Absorbance at 254 nm (ABS254nm), and True color was evaluated through RCCD (Rotatable Central Composite Design) experimental design, resulting in mathematical models that were statistically analyzed in Statistica and Design Expert software. The removals obtained was up to 26.1%, 29.9%, 56.9%, and 97.9% for COD ([COD]0=3,323 mg/L), TOC ([TOC]0=1,275 mg/L), ABS254nm (ABS0=32.2), and True color ([True color]0=3,467 mgPt-Co/L), respectively. Statistical and variance analysis of the experimental data revealed that one quadratic model obtained in Statistica was valid, ABS254nm reduction. However, by applying the Design Expert software, modified models were generated to predict the behavior of all dependent variables. Thus, the optimum point for the best response after ozonation of the landfill leachate was at the highest pH and the lowest ozone dose (9 and 2.2 mgO3/m3, respectively). Toxicity toward Allivibrio fischeri bacteria was abated at the same time that it decreased the impact of the effluent to Danio rerio fish (from 125 UT to 62 UT) on the treated leachate. Graphical Abstract
- Open Access
- 10 August 2021
- Published by IWA Publishing in Water Science & Technology
- Vol. 84 (6) , 1403-1416
Submerged microfiltration membrane and activated carbon processes for recalcitrant compounds removal in oil refinery effluent as electrodialysis pre-treatment
The combination of suspended activated carbon (AC) and submerged microfiltration (SMF) processes was applied to polish a biotreated effluent generated in a refinery industry. Preliminary results indicated that Norit 1240 W AC was more suitable than Carbomafra AC brand for total organic carbon (TOC) removal due to the highest Freundlich adsorption constant value (1.97 ± 0.42 and 0.96 ± 0.23 (mg/g)(L/mg)1/n, respectively), thus the first one was used in the combined system. Among all particle sizes of AC tested (0.041–1.01 mm), AC/SMF system was better performed, according to permeation flux, when applying granular AC instead of the powder one. On the other hand, the best response regarding TOC removal and absorbance at 254 nm (ABS254 nm) reduction were observed when applying powder AC (89% and 97%, respectively). Statistical analysis with two-sample T-test (p-value <0.05) endorsed the need of both air purge (20 L/h) and backwash strategies (8 min of permeation and 10 seconds of backwash) to diminish fouling occurrence in the SMF system. Finally, it was found that 2 g/L of Norit 1240 W PAC (0.041 mm particle size) condition fitted the effluent to further electrodialysis reversal (EDR) process (3.4 mg/L TOC) with consistent normalized permeate flux after 5 h of permeation (0.76 ± 0.1 J/J0).
- 10 August 2021
- Published by IWA Publishing in Water Science & Technology
- Vol. 84 (6) , 1403-1416
Open AccessSubmerged microfiltration membrane and activated carbon processes for recalcitrant compounds removal in oil refinery effluent as electrodialysis pre-treatment
The combination of suspended activated carbon (AC) and submerged microfiltration (SMF) processes was applied to polish a biotreated effluent generated in a refinery industry. Preliminary results indicated that Norit 1240 W AC was more suitable than Carbomafra AC brand for total organic carbon (TOC) removal due to the highest Freundlich adsorption constant value (1.97 ± 0.42 and 0.96 ± 0.23 (mg/g)(L/mg)1/n, respectively), thus the first one was used in the combined system. Among all particle sizes of AC tested (0.041–1.01 mm), AC/SMF system was better performed, according to permeation flux, when applying granular AC instead of the powder one. On the other hand, the best response regarding TOC removal and absorbance at 254 nm (ABS254 nm) reduction were observed when applying powder AC (89% and 97%, respectively). Statistical analysis with two-sample T-test (p-value <0.05) endorsed the need of both air purge (20 L/h) and backwash strategies (8 min of permeation and 10 seconds of backwash) to diminish fouling occurrence in the SMF system. Finally, it was found that 2 g/L of Norit 1240 W PAC (0.041 mm particle size) condition fitted the effluent to further electrodialysis reversal (EDR) process (3.4 mg/L TOC) with consistent normalized permeate flux after 5 h of permeation (0.76 ± 0.1 J/J0).
- Open Access
Evaluation of Nano Zero-Valent Iron (nZVI) Activity in Solution and Immobilized in Hydrophilic PVDF Membrane for Drimaren Red X-6BN and Bisphenol-a Removal in Water
Fenton reactions that involve nano zero-valent iron (nZVI) have shown high promise in the removal of organic pollutants. In this work, nZVI stabilized with carboxymethyl cellulose (CMC) was evaluated for drimaren red X-6BN (DRX-6BN, 10 mg/L) and bisphenol-a (BPA, 800 mg/L) removal. Oxidation reactions were conducted for removal of both compounds by varying nZVI/CMC concentration (0.01–5 g/L), hydrogen peroxide (H2O2, 0.01–0.1 g/L), and pH (3–9). DRX-6BN degradation rate was the highest (kinetic constant (kobs) = 4.622 h−1) when working at pH 3 and 3 g/L of nZVI/CMC. Increasing H2O2 concentration could not improve the reaction. For BPA, all the conditions tested showed removals of more than 96% with 0.02 g/L of H2O2. This result was compared with the activity of nZVI loaded in hydrophilic PVDF (Polyvinylidene fluoride) membranes by polyacrylic acid (PAA) to entrap nanoparticles to the membrane surface. As expected, the attachment of nZVI onto the membranes diminished nanoparticles’ activity; however, it is important to highlight the need for preparing a stable catalytic membrane, which could enhance pollutant removal of microfiltration membranes’ systems. This was confirmed by the percentage of iron leaching from functionalized membranes, where a higher concentration of iron in the bulk solution leads to enhancement on BPA removal. Issues with BPA diffusion resistance inside the pores were overcome by conducting the nZVI/PAA/PVDF membranes in the cross-flow system, reaching 40% of BPA removal after 3 h of permeation.
Open AccessEvaluation of Nano Zero-Valent Iron (nZVI) Activity in Solution and Immobilized in Hydrophilic PVDF Membrane for Drimaren Red X-6BN and Bisphenol-a Removal in Water
Fenton reactions that involve nano zero-valent iron (nZVI) have shown high promise in the removal of organic pollutants. In this work, nZVI stabilized with carboxymethyl cellulose (CMC) was evaluated for drimaren red X-6BN (DRX-6BN, 10 mg/L) and bisphenol-a (BPA, 800 mg/L) removal. Oxidation reactions were conducted for removal of both compounds by varying nZVI/CMC concentration (0.01–5 g/L), hydrogen peroxide (H2O2, 0.01–0.1 g/L), and pH (3–9). DRX-6BN degradation rate was the highest (kinetic constant (kobs) = 4.622 h−1) when working at pH 3 and 3 g/L of nZVI/CMC. Increasing H2O2 concentration could not improve the reaction. For BPA, all the conditions tested showed removals of more than 96% with 0.02 g/L of H2O2. This result was compared with the activity of nZVI loaded in hydrophilic PVDF (Polyvinylidene fluoride) membranes by polyacrylic acid (PAA) to entrap nanoparticles to the membrane surface. As expected, the attachment of nZVI onto the membranes diminished nanoparticles’ activity; however, it is important to highlight the need for preparing a stable catalytic membrane, which could enhance pollutant removal of microfiltration membranes’ systems. This was confirmed by the percentage of iron leaching from functionalized membranes, where a higher concentration of iron in the bulk solution leads to enhancement on BPA removal. Issues with BPA diffusion resistance inside the pores were overcome by conducting the nZVI/PAA/PVDF membranes in the cross-flow system, reaching 40% of BPA removal after 3 h of permeation.
- Open Access
- 2 May 2017
- Published by Instituto de Pesquisas Ambientais em Bacias Hidrograficas (IPABHi) in Ambiente e Agua - An Interdisciplinary Journal of Applied Science
- Vol. 12 (3) , 457-467
Estudo da tratabilidade de lixiviado gerado em um aterro controlado
O presente trabalho avaliou os processos de coagulação/floculação, adsorção em carvão ativado em pó (CAP) e reação com Fenton para redução da concentração dos poluentes e aumento da biodegradabilidade do lixiviado. No processo de coagulação/floculação foram avaliados o pH (4 a 8) e a concentração de cloreto férrico (100 a 600 mg L-1). No processo de adsorção em CAP, foram avaliadas as concentrações de 0,1-5,0 g L-1 de CAP, e na reação com Fenton, foram avaliadas as relações DQO:H2O2 [1:0,5, 1:1, 1:2 e 1:5], além das relações Fe:H2O2 [1:3, 1:5 e 1:10]. Nas melhores condições obtidas, foi avaliada a biodegradabilidade aeróbia dos efluentes tratados pelo método de Zahn-Wellens. O resultado do processo de coagulação/floculação foi de 22,9% de remoção da DQO e 64% de COT, utilizando 300 mg L-1 de coagulante em pH 4. Na adsorção em CAP, foram obtidas remoções de 69% da DQO, utilizando 5 g L-1 de carvão. Na reação de Fenton, foram alcançadas remoções de 82,3% de DQO (para DQO:H2O2=1:2 e Fe:H2O2 =1:3). Os resultados de biodegradabilidade aeróbia mostraram que apenas o lixiviado tratado com Fenton apresentou uma biodegradabilidade de 12 pontos percentuais maior em relação ao bruto, mostrando a sua potencialidade como pré-tratamento ao processo biológico.
- 2 May 2017
- Published by Instituto de Pesquisas Ambientais em Bacias Hidrograficas (IPABHi) in Ambiente e Agua - An Interdisciplinary Journal of Applied Science
- Vol. 12 (3) , 457-467
Open AccessEstudo da tratabilidade de lixiviado gerado em um aterro controlado
O presente trabalho avaliou os processos de coagulação/floculação, adsorção em carvão ativado em pó (CAP) e reação com Fenton para redução da concentração dos poluentes e aumento da biodegradabilidade do lixiviado. No processo de coagulação/floculação foram avaliados o pH (4 a 8) e a concentração de cloreto férrico (100 a 600 mg L-1). No processo de adsorção em CAP, foram avaliadas as concentrações de 0,1-5,0 g L-1 de CAP, e na reação com Fenton, foram avaliadas as relações DQO:H2O2 [1:0,5, 1:1, 1:2 e 1:5], além das relações Fe:H2O2 [1:3, 1:5 e 1:10]. Nas melhores condições obtidas, foi avaliada a biodegradabilidade aeróbia dos efluentes tratados pelo método de Zahn-Wellens. O resultado do processo de coagulação/floculação foi de 22,9% de remoção da DQO e 64% de COT, utilizando 300 mg L-1 de coagulante em pH 4. Na adsorção em CAP, foram obtidas remoções de 69% da DQO, utilizando 5 g L-1 de carvão. Na reação de Fenton, foram alcançadas remoções de 82,3% de DQO (para DQO:H2O2=1:2 e Fe:H2O2 =1:3). Os resultados de biodegradabilidade aeróbia mostraram que apenas o lixiviado tratado com Fenton apresentou uma biodegradabilidade de 12 pontos percentuais maior em relação ao bruto, mostrando a sua potencialidade como pré-tratamento ao processo biológico.
- 10 August 2016
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 24 (7) , 6329-6338
Advanced oxidative processes and membrane separation for micropollutant removal from biotreated domestic wastewater
The presence of micropollutants in sewage is already widely known, as well as the effects caused by natural and synthetic hormones. Thus, it is necessary to apply treatments to remove them from water systems, such as advanced oxidation processes (AOPs) and membrane separation processes, which can oxidize and remove high concentrations of organic compounds. This work investigated the removal of 17β-estradiol (E2), 17α-ethinylestradiol (EE2), and estriol (E3) from biotreated sewage. Reverse osmosis processes were conducted at three recoveries (50, 60, and 70 %). For E2 and EE2, the removals were affected by the recovery. The best results for RO were as follows: the E2 compound removal was 89 % for 60 % recovery and the EE2 compound removal was 57 % for 50 % recovery. The RO recovery did not impact the E3 removal. It was concluded that the interaction between the evaluated estrogens, and the membrane was the major factor for the hormone separation. The AOP treatment using H2O2/UV was carried out in two sampling campaigns. First, we evaluated the variation of UV doses (24.48, 73.44, 122.4, and 244.8 kJ m−2) with 18.8 mg L−1 of H2O2 in the reaction. EE2 showed considerable removals (around 70 %). In order to optimize the results, an experimental design was applied. The best result was obtained with higher UV dose (122.4 kJ m−2) and lower H2O2 concentration (4 mg L−1), achieving removal of 91 % for E3 and 100 % for E2 and EE2.
- 10 August 2016
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 24 (7) , 6329-6338
Advanced oxidative processes and membrane separation for micropollutant removal from biotreated domestic wastewater
The presence of micropollutants in sewage is already widely known, as well as the effects caused by natural and synthetic hormones. Thus, it is necessary to apply treatments to remove them from water systems, such as advanced oxidation processes (AOPs) and membrane separation processes, which can oxidize and remove high concentrations of organic compounds. This work investigated the removal of 17β-estradiol (E2), 17α-ethinylestradiol (EE2), and estriol (E3) from biotreated sewage. Reverse osmosis processes were conducted at three recoveries (50, 60, and 70 %). For E2 and EE2, the removals were affected by the recovery. The best results for RO were as follows: the E2 compound removal was 89 % for 60 % recovery and the EE2 compound removal was 57 % for 50 % recovery. The RO recovery did not impact the E3 removal. It was concluded that the interaction between the evaluated estrogens, and the membrane was the major factor for the hormone separation. The AOP treatment using H2O2/UV was carried out in two sampling campaigns. First, we evaluated the variation of UV doses (24.48, 73.44, 122.4, and 244.8 kJ m−2) with 18.8 mg L−1 of H2O2 in the reaction. EE2 showed considerable removals (around 70 %). In order to optimize the results, an experimental design was applied. The best result was obtained with higher UV dose (122.4 kJ m−2) and lower H2O2 concentration (4 mg L−1), achieving removal of 91 % for E3 and 100 % for E2 and EE2.