Huan Zheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Huan Zheng has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Feng Xu
College of Electrical Engineering; Zhejiang University; Hangzhou Zhejiang China
2 shared publicationsChi Zhang
1 shared publicationDaoZhuo Jiang
1 shared publicationDaozhuo Jiang
College of Electrical Engineering; Zhejiang University; Hangzhou Zhejiang China
1 shared publicationLiXin Ye
1 shared publicationLiang Yiqiao
College of Electrical Engineering; Zhejiang University; Hangzhou Zhejiang China
1 shared publication
Latest Publications
- 29 May 2014
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 25 (10) , 2058-2070
Optimum configuration for AC/DC converters of DC distribution network
Direct current (DC) distribution system might have two or more alternating current (AC)/DC interface converters, that is, one converter controlling the DC voltage and the others controlling their power injections. In this paper, an approach is proposed to address the configuration problem for the converters of DC distribution system. In order to improve the computational efficiency of the configuration process, the number of the interface converters is estimated and used for subsequent calculations. Then, a genetic algorithm is applied to minimize the total number of nodes whose voltages exceed the limits when N − 1 line contingency occurs. A new calculation method of objective function is also proposed, where a continuation power flow method is adopted for computational efficiency. The proposed configuration approach is verified with a 32-node DC distribution system, and the configuration scheme of the AC/DC interface converters is obtained. Copyright © 2014 John Wiley & Sons, Ltd.
- 29 May 2014
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 25 (10) , 2058-2070
Optimum configuration for AC/DC converters of DC distribution network
Direct current (DC) distribution system might have two or more alternating current (AC)/DC interface converters, that is, one converter controlling the DC voltage and the others controlling their power injections. In this paper, an approach is proposed to address the configuration problem for the converters of DC distribution system. In order to improve the computational efficiency of the configuration process, the number of the interface converters is estimated and used for subsequent calculations. Then, a genetic algorithm is applied to minimize the total number of nodes whose voltages exceed the limits when N − 1 line contingency occurs. A new calculation method of objective function is also proposed, where a continuation power flow method is adopted for computational efficiency. The proposed configuration approach is verified with a 32-node DC distribution system, and the configuration scheme of the AC/DC interface converters is obtained. Copyright © 2014 John Wiley & Sons, Ltd.
- 12 March 2014
- Published by Springer Nature in Science China Technological Sciences
- Vol. 57 (3) , 578-588
A positive Buck-Boost voltage balancer for DC distribution system
- 12 March 2014
- Published by Springer Nature in Science China Technological Sciences
- Vol. 57 (3) , 578-588
A positive Buck-Boost voltage balancer for DC distribution system