Weilu Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Weilu Liu has a total of 78 co-authors. Here are the top co-authors by number of shared publications:
Cong Li
College of Chemistry, Jilin University, Changchun 130012, China
13 shared publicationsYue Gu
College of Chemistry, Jilin University, Changchun 130012, China
13 shared publications- Zhiquan Zhang
College of Chemistry Jilin University Changchun P. R. China
11 shared publications Liu Tang
College of Chemistry, Jilin University, Changchun 130012, PR China
10 shared publicationsHaifeng Li
6 shared publicationsXiaoyi Yan
College of Chemistry, Jilin University, Changchun 130012, China
6 shared publications
Latest Publications
- Open Access
- 18 August 2025
- Published by Elsevier in Journal of Energy Chemistry
- Vol. 111, 545-556
Quantitative electroreduction of CO2 to CO using Re-oxide doped Ag aerogels with surface-supported ionic liquids
- 18 August 2025
- Published by Elsevier in Journal of Energy Chemistry
- Vol. 111, 545-556
Open AccessQuantitative electroreduction of CO2 to CO using Re-oxide doped Ag aerogels with surface-supported ionic liquids
- 11 June 2024
- Published by Springer Nature in Microchimica Acta
- Vol. 191 (7) , 1-12
A competitive-type photoelectrochemical aptasensor for 17 beta-estradiol detection in microfluidic devices based on a novel Au@Cd:SnO2/SnS2 nanocomposite
A competitive-type photoelectrochemical (PEC) aptasensor coupled with a novel Au@Cd:SnO2/SnS2 nanocomposite was designed for the detection of 17β-estradiol (E2) in microfluidic devices. The designed Au@Cd:SnO2/SnS2 nanocomposites exhibit high photoelectrochemical activity owing to the good matching of cascade band-edge and the efficient separation of photo-generated e−/h+ pairs derived from the Cd-doped defects in the energy level. The Au@Cd:SnO2/SnS2 nanocomposites were loaded into carbon paste electrodes (CPEs) to immobilize complementary DNA (cDNA) and estradiol aptamer probe DNA (E2-Apt), forming a double-strand DNA structure on the CPE surface. As the target E2 interacts with the double-strand DNA, E2-Apt is sensitively released from the CPE, subsequently increasing the photocurrent intensity due to the reduced steric hindrance of the electrode surface. The competitive-type sensing mechanism, combined with high PEC activity of the Au@Cd:SnO2/SnS2 nanocomposites, contributed to the rapid and sensitive detection of E2 in a “signal on” manner. Under the optimized conditions, the PEC aptasensor exhibited a linear range from 1.0 × 10−13 mol L−1 to 3.2 × 10−6 mol L−1 and a detection limit of 1.2 × 10−14 mol L−1 (S/N = 3). Moreover, the integration of microfluidic device with smartphone controlled portable electrochemical workstation enables the on-site detection of E2. The small sample volume (10 µL) and short analysis time (40 min) demonstrated the great potential of this strategy for E2 detection in rat serum and river water. With these advantages, the PEC aptasensor can be utilized for point-of-care testing (POCT) in both clinical and environmental applications. Graphical abstract
- 11 June 2024
- Published by Springer Nature in Microchimica Acta
- Vol. 191 (7) , 1-12
A competitive-type photoelectrochemical aptasensor for 17 beta-estradiol detection in microfluidic devices based on a novel Au@Cd:SnO2/SnS2 nanocomposite
A competitive-type photoelectrochemical (PEC) aptasensor coupled with a novel Au@Cd:SnO2/SnS2 nanocomposite was designed for the detection of 17β-estradiol (E2) in microfluidic devices. The designed Au@Cd:SnO2/SnS2 nanocomposites exhibit high photoelectrochemical activity owing to the good matching of cascade band-edge and the efficient separation of photo-generated e−/h+ pairs derived from the Cd-doped defects in the energy level. The Au@Cd:SnO2/SnS2 nanocomposites were loaded into carbon paste electrodes (CPEs) to immobilize complementary DNA (cDNA) and estradiol aptamer probe DNA (E2-Apt), forming a double-strand DNA structure on the CPE surface. As the target E2 interacts with the double-strand DNA, E2-Apt is sensitively released from the CPE, subsequently increasing the photocurrent intensity due to the reduced steric hindrance of the electrode surface. The competitive-type sensing mechanism, combined with high PEC activity of the Au@Cd:SnO2/SnS2 nanocomposites, contributed to the rapid and sensitive detection of E2 in a “signal on” manner. Under the optimized conditions, the PEC aptasensor exhibited a linear range from 1.0 × 10−13 mol L−1 to 3.2 × 10−6 mol L−1 and a detection limit of 1.2 × 10−14 mol L−1 (S/N = 3). Moreover, the integration of microfluidic device with smartphone controlled portable electrochemical workstation enables the on-site detection of E2. The small sample volume (10 µL) and short analysis time (40 min) demonstrated the great potential of this strategy for E2 detection in rat serum and river water. With these advantages, the PEC aptasensor can be utilized for point-of-care testing (POCT) in both clinical and environmental applications. Graphical abstract
- 3 May 2024
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 258, 116348
Needle-in-needle electrochemical sensor for in-vivo monitoring of anticancer drug etoposide
- 3 May 2024
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 258, 116348
Needle-in-needle electrochemical sensor for in-vivo monitoring of anticancer drug etoposide
- 1 March 2022
- Published by Springer Nature in Microchimica Acta
- Vol. 189 (3) , 1-9
Core–shell nanocomposite of flower-like molybdenum disulfide nanospheres and molecularly imprinted polymers for electrochemical detection of anti COVID-19 drug favipiravir in biological samples
A novel electrochemical sensor is reported for the detection of the antiviral drug favipiravir based on the core–shell nanocomposite of flower-like molybdenum disulfide (MoS2) nanospheres and molecularly imprinted polymers (MIPs). The MoS2@MIP core–shell nanocomposite was prepared via the electrodeposition of a MIP layer on the MoS2 modified electrode, using o-phenylenediamine as the monomer and favipiravir as the template. The selective binding of target favipiravir at the MoS2@MIP core–shell nanocomposite produced a redox signal in a concentration dependent manner, which was used for the quantitative analysis. The preparation process of the MoS2@MIP core–shell nanocomposite was optimized. Under the optimal conditions, the sensor exhibited a wide linear response range of 0.01 ~ 100 nM (1.57*10−6 ~ 1.57*10−2 μg mL−1) and a low detection limit of 0.002 nM (3.14*10−7 μg mL−1). Application of the sensor was demonstrated by detecting favipiravir in a minimum amount of 10 μL biological samples (urine and plasma). Satisfied results in the recovery tests indicated a high potential of favipiravir monitoring in infectious COVID-19 samples. Graphical abstract
- 1 March 2022
- Published by Springer Nature in Microchimica Acta
- Vol. 189 (3) , 1-9
Core–shell nanocomposite of flower-like molybdenum disulfide nanospheres and molecularly imprinted polymers for electrochemical detection of anti COVID-19 drug favipiravir in biological samples
A novel electrochemical sensor is reported for the detection of the antiviral drug favipiravir based on the core–shell nanocomposite of flower-like molybdenum disulfide (MoS2) nanospheres and molecularly imprinted polymers (MIPs). The MoS2@MIP core–shell nanocomposite was prepared via the electrodeposition of a MIP layer on the MoS2 modified electrode, using o-phenylenediamine as the monomer and favipiravir as the template. The selective binding of target favipiravir at the MoS2@MIP core–shell nanocomposite produced a redox signal in a concentration dependent manner, which was used for the quantitative analysis. The preparation process of the MoS2@MIP core–shell nanocomposite was optimized. Under the optimal conditions, the sensor exhibited a wide linear response range of 0.01 ~ 100 nM (1.57*10−6 ~ 1.57*10−2 μg mL−1) and a low detection limit of 0.002 nM (3.14*10−7 μg mL−1). Application of the sensor was demonstrated by detecting favipiravir in a minimum amount of 10 μL biological samples (urine and plasma). Satisfied results in the recovery tests indicated a high potential of favipiravir monitoring in infectious COVID-19 samples. Graphical abstract
- 1 November 2018
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 272, 655-661
Electrodeposited Pt@Molecularly imprinted polymer core-shell nanostructure: Enhanced sensing platform for sensitive and selective detection of bisphenol A
- 1 November 2018
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 272, 655-661
Electrodeposited Pt@Molecularly imprinted polymer core-shell nanostructure: Enhanced sensing platform for sensitive and selective detection of bisphenol A