MSMatthew H. Steinecker

Matthew H. Steinecker

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Matthew H. Steinecker has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Vector magnetometry using cavity-enhanced microwave readout in nitrogen-vacancy-center diamond

    by Reginald Wilcox, David Phillips, Matthew Steinecker, Erik Eisenach, Corey Hawkins, Linh Pham, Jennifer Schloss, Dirk Englund, Danielle Braje


  • Top Cited Papers

    Sensitive ac and dc magnetometry with nitrogen-vacancy-center ensembles in diamond

    by John F. Barry, Matthew H. Steinecker, Scott T. Alsid, Jonah Majumder, Linh M. Pham, Michael F. O’kEeffe, Danielle A. Braje

    Quantum sensing with solid-state spins offers the promise of high spatial resolution, bandwidth, and dynamic range at sensitivities comparable to more mature quantum sensing technologies, such as atomic vapor cells and superconducting devices. However, despite comparable theoretical sensitivity limits, the performance of bulk solid-state quantum sensors has so far lagged behind these more mature alternatives. A recent review [Barry et al., Rev. Mod. Phys. 92, 015004 (2020)] suggests several paths to improve performance of magnetometers employing nitrogen-vacancy defects in diamond, the most-studied solid-state quantum sensing platform. Implementing several suggested techniques, we demonstrate the most sensitive nitrogen-vacancy-based bulk magnetometer reported to date. Our approach combines tailored diamond growth to achieve low strain and long intrinsic dephasing times, the use of double-quantum Ramsey and Hahn-echo magnetometry sequences for broadband and narrowband magnetometry, respectively, and P1 driving to further extend dephasing time. Notably, the device does not include a flux concentrator, preserving the fixed response of the nitrogen vacancies to magnetic field. The magnetometer realizes a minimum sensitivity of 460fTs1/2 in a broadband dc-sensitive mode and 210fTs1/2 in a narrowband ac mode. We describe the experimental setup in detail and highlight potential paths for future improvement.


  • Solid-State Microwave Magnetometer with Picotesla-Level Sensitivity

    by Scott T. Alsid, Jennifer M. Schloss, Matthew H. Steinecker, John F. Barry, Andrew C. Maccabe, Guoqing Wang, Paola Cappellaro, Danielle A. Braje

    Quantum sensing of low-frequency magnetic fields using nitrogen-vacancy– (N-V) center ensembles has been demonstrated in multiple experiments with sensitivities as low as approximately 1pT/Hz. To date, however, demonstrations of high-frequency magnetometry in the gigahertz regime with N-V diamond are orders of magnitude less sensitive, above the nT/Hz level. Here, we adapt, for microwave frequencies, techniques that have enabled high-performance low-frequency quantum sensors. Using a custom-grown N-V–enriched diamond combined with a noise-cancellation scheme designed for high-frequency sensing, we demonstrate a Rabi-sequence-based magnetometer able to detect microwave fields near 2.87 GHz with a record sensitivity of 3.4pT/Hz. We demonstrate both amplitude and phase sensing and project tunability over a 300-MHz frequency range. This result increases the viability of N-V ensembles to serve as microwave circuitry imagers and near-field probes of antennas.


  • Ferrimagnetic Oscillator Magnetometer

    by John F. Barry, Reed A. Irion, Matthew H. Steinecker, Daniel K. Freeman, Jessica J. Kedziora, Reginald G. Wilcox, Danielle A. Braje

    Quantum sensors offer unparalleled precision, accuracy, and sensitivity for a variety of measurement applications. We report a compact magnetometer based on a ferrimagnetic sensing element in an oscillator architecture that circumvents challenges common to other quantum sensing approaches such as limited dynamic range, limited bandwidth, and dependence on vacuum, cryogenic, or laser components. The device exhibits a fixed, calibration-free response governed by the electron gyromagnetic ratio. Exchange narrowing in the ferrimagnetic material produces submegahertz transition linewidths despite the high unpaired spin density (approximately 1022cm−3). The magnetometer achieves a minimum sensitivity of 100 fT/Hz to ac magnetic fields of unknown phase and a sensitivity below 200 fT/Hz over a 1 MHz bandwidth. By encoding magnetic field in frequency rather than amplitude, the device provides a dynamic range in excess of 1 mT. The passive, thermal initialization of the sensor’s quantum state requires only a magnetic bias field, greatly reducing power requirements compared to laser-initialized quantum sensors. With additional development, this device promises to be a leading candidate for high-performance magnetometry outside the laboratory, and the oscillator architecture is expected to provide advantages across a wide range of sensing platforms.


  • Thermally Polarized Solid-State Spin Sensor

    by Reginald Wilcox, Erik Eisenach, John Barry, Matthew Steinecker, Michael O’kEeffe, Dirk Englund, Danielle Braje

    Quantum sensors based on spin defect ensembles have seen rapid development in recent years, with a wide array of target applications. Historically, these sensors have used optical methods to prepare or read out quantum states. However, these methods are limited to optically polarizable spin defects, and the spin ensemble size is typically limited by the available optical power or acceptable optical heat load. We demonstrate a solid-state sensor employing a nonoptical state preparation technique, which harnesses thermal population imbalances induced by the defects’ zero-field splitting. Readout is performed using the recently demonstrated microwave cavity readout technique, resulting in a sensor architecture that is entirely nonoptical and broadly applicable to all solid-state paramagnetic defects with a zero-field splitting. The implementation in this work uses Cr3+ defects in a sapphire (Al2O3) crystal and a simple microwave architecture where the host crystal also serves as the high quality-factor resonator. This approach yields a near-unity filling factor and high single-spin-photon coupling, producing a broadband magnetometer with a minimum sensitivity of 9.7pT/Hz near 5 kHz.


  • Magnetic Trapping of an Ultracold Gas of Polar Molecules

    by D. J. McCarron, M. H. Steinecker, Y. Zhu, D. DeMille

    We demonstrate the efficient transfer of molecules from a magneto-optical trap into a conservative magnetic quadrupole trap. Our scheme begins with a blue-detuned optical molasses to cool SrF molecules to ≈50  μK. Next, we optically pump the molecules into a strongly trapped sublevel. This two-step process reliably transfers ≈40% of the molecules initially trapped in the magneto-optical trap into a single quantum state in the magnetic trap. Once loaded, the molecule cloud is compressed by increasing the magnetic field gradient. We observe a magnetic trap lifetime of over 1 s. This opens a promising new path to study ultracold molecular collisions, and potentially to produce quantum-degenerate molecular gases via sympathetic cooling with co-trapped atoms.


  • Improved Radio‐Frequency Magneto‐Optical Trap of SrF Molecules

    by Matthew H. Steinecker, Daniel J. McCarron, Yuqi Zhu, David DeMille

    We report the production of ultracold, trapped strontium monofluoride (SrF) molecules with number density and phase‐space density significantly higher than previously achieved. These improvements are enabled by three distinct changes to our recently‐demonstrated scheme for radio‐frequency magneto‐optical trapping of SrF: modification of the slowing laser beam geometry, addition of an optical pumping laser, and incorporation of a compression stage to the magneto‐optical trap. With these improvements, we observe a trapped sample of SrF molecules at density 2.5×105 cm−3 and phase‐space density 6×10−14, each a factor of 4 greater than in previous work. Under different experimental conditions, we observe trapping of up to 104 molecules, a factor of 5 greater than in previous work. Finally, by reducing the intensity of the applied trapping light, we observe molecular temperatures as low as 250 μK.


  • A low-cost, FPGA-based servo controller with lock-in amplifier

    by G Yang, J F Barry, E S Shuman, M H Steinecker, D DeMille