Shiraz Rahim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shiraz Rahim has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
John Haaga
University Hospitals Case Medical Center, Department of Radiology, 11100 Euclid Ave, Cleveland, OH 44106
3 shared publicationsDean Nakamoto
University Hospitals Case Medical Center, Department of Radiology, 11100 Euclid Ave, Cleveland, OH 44106
2 shared publicationsJon Davidson
University Hospitals Case Medical Center, Department of Radiology, 11100 Euclid Ave, Cleveland, OH 44106
2 shared publications- Indravadan J. Patel
Department of Radiology, Center for Interventional Radiology, University Hospitals Cleveland Medical Center, Case Western Reserve University, Cleveland, Ohio
1 shared publication Indravadan Patel
University Hospitals Case Medical Center, Department of Radiology, 11100 Euclid Ave, Cleveland, OH 44106
1 shared publicationPablo Ros
Both authors: Department of Radiology, University Hospitals Case Medical Center, 11100 Euclid Ave, Cleveland, OH 44106
1 shared publication
Latest Publications
- 1 December 2018
- Published by Elsevier in Academic Radiology
- Vol. 25 (12) , 1617-1623
Comparison of Local Injection of Fresh Frozen Plasma to Traditional Methods of Hemostasis in Minimally Invasive Procedures
- 1 December 2018
- Published by Elsevier in Academic Radiology
- Vol. 25 (12) , 1617-1623
Comparison of Local Injection of Fresh Frozen Plasma to Traditional Methods of Hemostasis in Minimally Invasive Procedures
- Open Access
- 1 December 2017
- Published by Georg Thieme Verlag KG
- Vol. 01 (S 04) , P032
Comparing the Effectiveness of Different Hemostatic Methods in Minimally Invasive Intervention
Purpose To determine and compare effectiveness of various methods of local hemostasis in patients with elevated international normalized ratio (INR) undergoing imaging-guided interventions, such as solid organ biopsy. Materials and Methods Retrospective chart review was performed of 182 patients with elevated INR (average INR of 2.3) undergoing ultrasound or computed tomography (CT)-guided solid organ biopsy or cholangiogram. Patients underwent either injection of a small amount of fresh frozen plasma (FFP), Gelfoam, or embolization coils through the tract sites to provide hemostasis after the procedure. This was compared with an equal number of patients undergoing systemic fresh frozen plasma infusion through peripheral intravenous (IV) for elevated INR prior to ultrasound and CT-guided solid organ biopsies or cholangiograms. Size of tracts and amounts of injections were all obtained and controlled during data analysis. Rates of clinically significant and insignificant bleeding and additional complications were calculated and compared. A threshold of 30cc of blood loss after the procedure was used as a marker of significant bleeding. Clinically significant bleeding was defined as blood loss causing symptoms and/or requiring intervention, such as additional invasive procedure or blood product transfusion. Results In patients receiving local injection of FFP, all type bleeding rate and clinically significant bleeding rate was 0%. In patients receiving Gelfoam tract plugging, the bleeding rate was 12.5% with a clinically significant bleeding rate of 0%. In patients for whom embolization coils were used to manage bleeding, there was a 37.5% rate of all types of bleeding and a 12.5% rate of clinically significant bleeding requiring intervention or blood products. In patients receiving systemic FFP only, the all type bleeding rate was 17.1%, and clinically significant bleeding rate was 2.8%. Fifteen percent of patients experienced a transfusion-related complication including three deaths directly attributable to infusion-related volume overload or transfusion allergic reaction. Conclusion Local injection of FFP provides a low-risk alternative for hemostasis in patients with coagulopathy undergoing minimally invasive procedures. This technique is comparable, if not superior, to more commonly used methods of reducing operative bleeding risk including synthetic fibrin injection and systemic FFP infusion. Local injection also allows interventionalists to avoid significant complications associated with systemic infusion of blood products including volume overload and allergic reactions while still reducing risk of bleeding.
- 1 December 2017
- Published by Georg Thieme Verlag KG
- Vol. 01 (S 04) , P032
Open AccessComparing the Effectiveness of Different Hemostatic Methods in Minimally Invasive Intervention
Purpose To determine and compare effectiveness of various methods of local hemostasis in patients with elevated international normalized ratio (INR) undergoing imaging-guided interventions, such as solid organ biopsy. Materials and Methods Retrospective chart review was performed of 182 patients with elevated INR (average INR of 2.3) undergoing ultrasound or computed tomography (CT)-guided solid organ biopsy or cholangiogram. Patients underwent either injection of a small amount of fresh frozen plasma (FFP), Gelfoam, or embolization coils through the tract sites to provide hemostasis after the procedure. This was compared with an equal number of patients undergoing systemic fresh frozen plasma infusion through peripheral intravenous (IV) for elevated INR prior to ultrasound and CT-guided solid organ biopsies or cholangiograms. Size of tracts and amounts of injections were all obtained and controlled during data analysis. Rates of clinically significant and insignificant bleeding and additional complications were calculated and compared. A threshold of 30cc of blood loss after the procedure was used as a marker of significant bleeding. Clinically significant bleeding was defined as blood loss causing symptoms and/or requiring intervention, such as additional invasive procedure or blood product transfusion. Results In patients receiving local injection of FFP, all type bleeding rate and clinically significant bleeding rate was 0%. In patients receiving Gelfoam tract plugging, the bleeding rate was 12.5% with a clinically significant bleeding rate of 0%. In patients for whom embolization coils were used to manage bleeding, there was a 37.5% rate of all types of bleeding and a 12.5% rate of clinically significant bleeding requiring intervention or blood products. In patients receiving systemic FFP only, the all type bleeding rate was 17.1%, and clinically significant bleeding rate was 2.8%. Fifteen percent of patients experienced a transfusion-related complication including three deaths directly attributable to infusion-related volume overload or transfusion allergic reaction. Conclusion Local injection of FFP provides a low-risk alternative for hemostasis in patients with coagulopathy undergoing minimally invasive procedures. This technique is comparable, if not superior, to more commonly used methods of reducing operative bleeding risk including synthetic fibrin injection and systemic FFP infusion. Local injection also allows interventionalists to avoid significant complications associated with systemic infusion of blood products including volume overload and allergic reactions while still reducing risk of bleeding.
- 1 December 2016
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 207 (6) , 1232-1238
Moving Away From Spoon-Feeding as a Teaching Style in Radiology
OBJECTIVE. Medical education has been an important topic in the literature, with many new attempts to revitalize and improve efforts to teach physicians and students. As a unique subspecialty that incorporates visual learning, knowledge of clinical management and presentation, basic science topics such as physics and mechanics, and procedural skills, radiology affords itself to new and more effective methods of teaching. CONCLUSION. Much of radiology education has currently focused on the concept of spoon-feeding information from the teacher to the learners. This article outlines the dangers of this approach in radiology and offers solutions for educators to improve their teaching skills and use the potential afforded by the diversity of the field.
- 1 December 2016
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 207 (6) , 1232-1238
Moving Away From Spoon-Feeding as a Teaching Style in Radiology
OBJECTIVE. Medical education has been an important topic in the literature, with many new attempts to revitalize and improve efforts to teach physicians and students. As a unique subspecialty that incorporates visual learning, knowledge of clinical management and presentation, basic science topics such as physics and mechanics, and procedural skills, radiology affords itself to new and more effective methods of teaching. CONCLUSION. Much of radiology education has currently focused on the concept of spoon-feeding information from the teacher to the learners. This article outlines the dangers of this approach in radiology and offers solutions for educators to improve their teaching skills and use the potential afforded by the diversity of the field.
- 8 November 2016
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 40 (2) , 231-235
Direct Injection of Blood Products Versus Gelatin Sponge as a Technique for Local Hemostasis
To provide a method of reducing risk of minimally invasive procedures on patients with abnormal hemostasis and evaluate efficacy of direct fresh frozen plasma injection through a procedure needle tract compared to Gelfoam (gelatin sponge) administration. Eighty patients with elevated international standardized ratio (INR) undergoing minimally invasive procedures using imaging guidance were selected retrospectively. Forty patients had received Gelfoam as a means of tract embolization during the procedure. The other 40 received local fresh frozen plasma (FFP) through the needle tract. The number of complications and clinically significant bleeding events were recorded. A threshold of 30 cc of blood loss after a procedure was used to identify excess bleeding. No patients experienced clinically significant bleeding after administration of FFP. Five patients experienced postoperative drops in hemoglobin or hematomas after administration of Gelfoam. Local injection of blood products can reduce postprocedure bleeding in patients undergoing minimally invasive procedures and provides a safe alternative to the use of synthetic fibrin plugs.
- 8 November 2016
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 40 (2) , 231-235
Direct Injection of Blood Products Versus Gelatin Sponge as a Technique for Local Hemostasis
To provide a method of reducing risk of minimally invasive procedures on patients with abnormal hemostasis and evaluate efficacy of direct fresh frozen plasma injection through a procedure needle tract compared to Gelfoam (gelatin sponge) administration. Eighty patients with elevated international standardized ratio (INR) undergoing minimally invasive procedures using imaging guidance were selected retrospectively. Forty patients had received Gelfoam as a means of tract embolization during the procedure. The other 40 received local fresh frozen plasma (FFP) through the needle tract. The number of complications and clinically significant bleeding events were recorded. A threshold of 30 cc of blood loss after a procedure was used to identify excess bleeding. No patients experienced clinically significant bleeding after administration of FFP. Five patients experienced postoperative drops in hemoglobin or hematomas after administration of Gelfoam. Local injection of blood products can reduce postprocedure bleeding in patients undergoing minimally invasive procedures and provides a safe alternative to the use of synthetic fibrin plugs.