Christopher Hann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Christopher Hann has a total of 80 co-authors. Here are the top co-authors by number of shared publications:
- James Geoffrey Chase
University of Canterbury
14 shared publications - Geoffrey M. Shaw
Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
7 shared publications G.M. Shaw
6 shared publications- Thomas Desaive
GIGA-In Silico Medicine, University of Liège, Liège, Belgium
5 shared publications Geoffrey M. Shaw
University of Otago School of Medicine, Christchurch, New Zealand, and Department of Intensive Care, Christchurch Hospital, New Zealand
4 shared publications- Xiaoqi Chen
South China University of Technology
4 shared publications
Latest Publications
- Open Access
Vertical Wind Tunnel for Prediction of Rocket Flight Dynamics
A customized vertical wind tunnel has been built by the University of Canterbury Rocketry group (UC Rocketry). This wind tunnel has been critical for the success of UC Rocketry as it allows the optimization of avionics and control systems before flight. This paper outlines the construction of the wind tunnel and includes an analysis of flow quality including swirl. A minimal modelling methodology for roll dynamics is developed that can extrapolate wind tunnel behavior at low wind speeds to much higher velocities encountered during flight. The models were shown to capture the roll flight dynamics in two rocket launches with mean roll angle errors varying from 0.26° to 1.5° across the flight data. The identified model parameters showed consistent and predictable variations over both wind tunnel tests and flight, including canard–fin interaction behavior. These results demonstrate that the vertical wind tunnel is an important tool for the modelling and control of sounding rockets.
Open AccessVertical Wind Tunnel for Prediction of Rocket Flight Dynamics
A customized vertical wind tunnel has been built by the University of Canterbury Rocketry group (UC Rocketry). This wind tunnel has been critical for the success of UC Rocketry as it allows the optimization of avionics and control systems before flight. This paper outlines the construction of the wind tunnel and includes an analysis of flow quality including swirl. A minimal modelling methodology for roll dynamics is developed that can extrapolate wind tunnel behavior at low wind speeds to much higher velocities encountered during flight. The models were shown to capture the roll flight dynamics in two rocket launches with mean roll angle errors varying from 0.26° to 1.5° across the flight data. The identified model parameters showed consistent and predictable variations over both wind tunnel tests and flight, including canard–fin interaction behavior. These results demonstrate that the vertical wind tunnel is an important tool for the modelling and control of sounding rockets.
- 1 April 2015
- Published by Elsevier in Mathematical Biosciences
- Vol. 262, 182-197
Robust global identifiability theory using potentials—Application to compartmental models
- 1 April 2015
- Published by Elsevier in Mathematical Biosciences
- Vol. 262, 182-197
Robust global identifiability theory using potentials—Application to compartmental models
- Open Access
The Development of Rocketry Capability in New Zealand—World Record Rocket and First of Its Kind Rocketry Course
The University of Canterbury has developed a rocket research group, UC Rocketry, which recently broke the world altitude record for an I-class motor (impulse of 320–640 Ns) and has run a rocketry course for the first time in New Zealand. This paper discusses the development and results of the world record rocket “Milly” and details all the fundamental elements of the rocketry final year engineering course, including the manufacturing processes, wind tunnel testing, avionics, control and the final rocket launch of “Smokey”. The rockets Milly and Smokey are an example of the design, implementation and testing methodologies that have significantly contributed to research and graduates for New Zealand’s space program.
Open AccessThe Development of Rocketry Capability in New Zealand—World Record Rocket and First of Its Kind Rocketry Course
The University of Canterbury has developed a rocket research group, UC Rocketry, which recently broke the world altitude record for an I-class motor (impulse of 320–640 Ns) and has run a rocketry course for the first time in New Zealand. This paper discusses the development and results of the world record rocket “Milly” and details all the fundamental elements of the rocketry final year engineering course, including the manufacturing processes, wind tunnel testing, avionics, control and the final rocket launch of “Smokey”. The rockets Milly and Smokey are an example of the design, implementation and testing methodologies that have significantly contributed to research and graduates for New Zealand’s space program.
- Open Access
- 21 September 2012
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 11 (1) , 73
Beat-to-beat estimation of the continuous left and right cardiac elastance from metrics commonly available in clinical settings
Introduction: Functional time-varying cardiac elastances (FTVE) contain a rich amount of information about the specific cardiac state of a patient. However, a FTVE waveform is very invasive to directly measure, and is thus currently not used in clinical practice. This paper presents a method for the estimation of a patient specific FTVE, using only metrics that are currently available in a clinical setting. Method: Correlations are defined between invasively measured FTVE waveforms and the aortic and pulmonary artery pressures from 2 cohorts of porcine subjects, 1 induced with pulmonary embolism, the other with septic shock. These correlations are then used to estimate the FTVE waveform based on the individual aortic and pulmonary artery pressure waveforms, using the “other” dysfunction’s correlations as a cross validation. Results: The cross validation resulted in 1.26% and 2.51% median errors for the left and right FTVE respectively on pulmonary embolism, while the septic shock cohort had 2.54% and 2.90% median errors. Conclusions: The presented method accurately and reliably estimated a patient specific FTVE, with no added risk to the patient. The cross validation shows that the method is not dependent on dysfunction and thus has the potential for generalisation beyond pulmonary embolism and septic shock.
- 21 September 2012
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 11 (1) , 73
Open AccessBeat-to-beat estimation of the continuous left and right cardiac elastance from metrics commonly available in clinical settings
Introduction: Functional time-varying cardiac elastances (FTVE) contain a rich amount of information about the specific cardiac state of a patient. However, a FTVE waveform is very invasive to directly measure, and is thus currently not used in clinical practice. This paper presents a method for the estimation of a patient specific FTVE, using only metrics that are currently available in a clinical setting. Method: Correlations are defined between invasively measured FTVE waveforms and the aortic and pulmonary artery pressures from 2 cohorts of porcine subjects, 1 induced with pulmonary embolism, the other with septic shock. These correlations are then used to estimate the FTVE waveform based on the individual aortic and pulmonary artery pressure waveforms, using the “other” dysfunction’s correlations as a cross validation. Results: The cross validation resulted in 1.26% and 2.51% median errors for the left and right FTVE respectively on pulmonary embolism, while the septic shock cohort had 2.54% and 2.90% median errors. Conclusions: The presented method accurately and reliably estimated a patient specific FTVE, with no added risk to the patient. The cross validation shows that the method is not dependent on dysfunction and thus has the potential for generalisation beyond pulmonary embolism and septic shock.
- 1 August 2012
- Published by Elsevier in Expert Systems with Applications
- Vol. 39 (10) , 8636-8644
Nonparametric control algorithms for a pneumatic artificial muscle
- 1 August 2012
- Published by Elsevier in Expert Systems with Applications
- Vol. 39 (10) , 8636-8644
Nonparametric control algorithms for a pneumatic artificial muscle
- Open Access
- 15 June 2012
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 11 (1) , 28
Algorithmic processing of pressure waveforms to facilitate estimation of cardiac elastance
Background: Cardiac elastances are highly invasive to measure directly, but are clinically useful due to the amount of information embedded in them. Information about the cardiac elastance, which can be used to estimate it, can be found in the downstream pressure waveforms of the aortic pressure (P ao ) and the pulmonary artery (P pa ). However these pressure waveforms are typically noisy and biased, and require processing in order to locate the specific information required for cardiac elastance estimations. This paper presents the method to algorithmically process the pressure waveforms. Methods: A shear transform is developed in order to help locate information in the pressure waveforms. This transform turns difficult to locate corners into easy to locate maximum or minimum points as well as providing error correction. Results: The method located all points on 87 out of 88 waveforms for P pa , to within the sampling frequency. For P ao , out of 616 total points, 605 were found within 1%, 5 within 5%, 4 within 10% and 2 within 20%. Conclusions: The presented method provides a robust, accurate and dysfunction-independent way to locate points on the aortic and pulmonary artery pressure waveforms, allowing the non-invasive estimation of the left and right cardiac elastance.
- 15 June 2012
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 11 (1) , 28
Open AccessAlgorithmic processing of pressure waveforms to facilitate estimation of cardiac elastance
Background: Cardiac elastances are highly invasive to measure directly, but are clinically useful due to the amount of information embedded in them. Information about the cardiac elastance, which can be used to estimate it, can be found in the downstream pressure waveforms of the aortic pressure (P ao ) and the pulmonary artery (P pa ). However these pressure waveforms are typically noisy and biased, and require processing in order to locate the specific information required for cardiac elastance estimations. This paper presents the method to algorithmically process the pressure waveforms. Methods: A shear transform is developed in order to help locate information in the pressure waveforms. This transform turns difficult to locate corners into easy to locate maximum or minimum points as well as providing error correction. Results: The method located all points on 87 out of 88 waveforms for P pa , to within the sampling frequency. For P ao , out of 616 total points, 605 were found within 1%, 5 within 5%, 4 within 10% and 2 within 20%. Conclusions: The presented method provides a robust, accurate and dysfunction-independent way to locate points on the aortic and pulmonary artery pressure waveforms, allowing the non-invasive estimation of the left and right cardiac elastance.
- 1 February 2011
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 101 (2) , 201-207
Patient specific identification of the cardiac driver function in a cardiovascular system model
- 1 February 2011
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 101 (2) , 201-207
Patient specific identification of the cardiac driver function in a cardiovascular system model
- Open Access
- 1 January 2011
- Published by Elsevier in Annals of Intensive Care
- Vol. 1 (1) , 33
Clinical detection and monitoring of acute pulmonary embolism: proof of concept of a computer-based method
- 1 January 2011
- Published by Elsevier in Annals of Intensive Care
- Vol. 1 (1) , 33
Open AccessClinical detection and monitoring of acute pulmonary embolism: proof of concept of a computer-based method
- 30 September 2010
- Published by Elsevier in Mathematical Biosciences
- Vol. 227 (1) , 44-55
A fast generalizable solution method for glucose control algorithms
- 30 September 2010
- Published by Elsevier in Mathematical Biosciences
- Vol. 227 (1) , 44-55
A fast generalizable solution method for glucose control algorithms
- Open Access
- 27 July 2010
- Published by Bentham Science Publishers Ltd. in The Open Medical Informatics Journal
- Vol. 4 (1) , 149-163
Model-Based Prediction of the Patient-Specific Response to Adrenaline
A model for the cardiovascular and circulatory systems has previously been validated in simulated cardiac and circulatory disease states. It has also been shown to accurately capture the main hemodynamic trends in porcine models of pulmonary embolism and PEEP (positive end-expiratory pressure) titrations at different volemic levels. In this research, the existing model and parameter identification process are used to study the effect of different adrenaline doses in healthy and critically ill patient populations, and to develop a means of predicting the hemodynamic response to adrenaline. The hemodynamic effects on arterial blood pressures and stroke volume (cardiac index) are simulated in the model and adrenaline-specific parameters are identified. The dose dependent changes in these parameters are then related to adrenaline dose using data from studies published in the literature. These relationships are then used to predict the future, patient-specific response to a change in dose or over time periods from 1-12 hours. The results are compared to data from 3 published adrenaline dosing studies comprising a total of 37 data sets. Absolute percentage errors for the identified model are within 10% when re-simulated and compared to clinical data for all cases. All identified parameter trends match clinically expected changes. Absolute percentage errors for the predicted hemodynamic responses (N=15) are also within 10% when re-simulated and compared to clinical data. Clinically accurate prediction of the effect of inotropic circulatory support drugs, such as adrenaline, offers significant potential for this type of model-based application. Overall, this work represents a further clinical, proof of concept, of the underlying fundamental mathematical model, methods and approach, as well as providing a template for using the model in clinical titration of adrenaline in a decision support role in critical care. They are thus a further justification in support of upcoming human clinical trials to validate this model.
- 27 July 2010
- Published by Bentham Science Publishers Ltd. in The Open Medical Informatics Journal
- Vol. 4 (1) , 149-163
Open AccessModel-Based Prediction of the Patient-Specific Response to Adrenaline
A model for the cardiovascular and circulatory systems has previously been validated in simulated cardiac and circulatory disease states. It has also been shown to accurately capture the main hemodynamic trends in porcine models of pulmonary embolism and PEEP (positive end-expiratory pressure) titrations at different volemic levels. In this research, the existing model and parameter identification process are used to study the effect of different adrenaline doses in healthy and critically ill patient populations, and to develop a means of predicting the hemodynamic response to adrenaline. The hemodynamic effects on arterial blood pressures and stroke volume (cardiac index) are simulated in the model and adrenaline-specific parameters are identified. The dose dependent changes in these parameters are then related to adrenaline dose using data from studies published in the literature. These relationships are then used to predict the future, patient-specific response to a change in dose or over time periods from 1-12 hours. The results are compared to data from 3 published adrenaline dosing studies comprising a total of 37 data sets. Absolute percentage errors for the identified model are within 10% when re-simulated and compared to clinical data for all cases. All identified parameter trends match clinically expected changes. Absolute percentage errors for the predicted hemodynamic responses (N=15) are also within 10% when re-simulated and compared to clinical data. Clinically accurate prediction of the effect of inotropic circulatory support drugs, such as adrenaline, offers significant potential for this type of model-based application. Overall, this work represents a further clinical, proof of concept, of the underlying fundamental mathematical model, methods and approach, as well as providing a template for using the model in clinical titration of adrenaline in a decision support role in critical care. They are thus a further justification in support of upcoming human clinical trials to validate this model.