Latest Publications
- 1 June 2024
- Published by Springer Nature
- p. 200-211
An Ontology-Based Meta-modelling Approach for Semantic-Driven Building Management Systems
- 1 June 2024
- Published by Springer Nature
- p. 200-211
An Ontology-Based Meta-modelling Approach for Semantic-Driven Building Management Systems
- 1 June 2024
- Published by Springer Nature
- p. 53-58
A Hierarchical Knowledge Framework for Digital Twins of Buildings and Their Energy Systems (Position Paper)
- 1 June 2024
- Published by Springer Nature
- p. 53-58
A Hierarchical Knowledge Framework for Digital Twins of Buildings and Their Energy Systems (Position Paper)
- Open Access
- 30 March 2022
- Published by Elsevier in Applied Energy
- Vol. 314
MANGOret: An optimization framework for the long-term investment planning of building multi-energy system and envelope retrofits
- 30 March 2022
- Published by Elsevier in Applied Energy
- Vol. 314
Open AccessMANGOret: An optimization framework for the long-term investment planning of building multi-energy system and envelope retrofits
- Open Access
- 1 January 2022
- Published by Elsevier in Building and Environment
- Vol. 208
Information modelling for urban building energy simulation—A taxonomic review
- 1 January 2022
- Published by Elsevier in Building and Environment
- Vol. 208
Open AccessInformation modelling for urban building energy simulation—A taxonomic review
- Open Access
- 1 November 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1343 (1) , 012105
Characterization of heat-pump, PV and battery demonstrator technologies using a coherent energy assessment
Battery, PV and heat-pump technologies were characterized using a Coherent Energy Demonstrator Assessment (CEDA) approach. In all cases the calibrated simulation models closely matched the measured data; however it is not possible to conclusively say that models, based on a single demonstrator, represent all existing and future cases of a technology. A possible solution would require additional operators to characterize and report the performance of a given technology, in a standardized way, and the resulting data could then contribute to an evolving set of representative CEDA archetypes to be used in studies of energy systems.
- 1 November 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1343 (1) , 012105
Open AccessCharacterization of heat-pump, PV and battery demonstrator technologies using a coherent energy assessment
Battery, PV and heat-pump technologies were characterized using a Coherent Energy Demonstrator Assessment (CEDA) approach. In all cases the calibrated simulation models closely matched the measured data; however it is not possible to conclusively say that models, based on a single demonstrator, represent all existing and future cases of a technology. A possible solution would require additional operators to characterize and report the performance of a given technology, in a standardized way, and the resulting data could then contribute to an evolving set of representative CEDA archetypes to be used in studies of energy systems.
- 17 July 2017
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 139 (5)
Computational Fluid Dynamics Simulation and Experimental Study of Key Design Parameters of Solar Thermal Collectors
Numerical simulation enables the optimization of a solar collector without the expense of building prototypes. This study details an approach using computational fluid dynamics (CFD) to simulate the performance of a solar thermal collector. Inputs to the simulation include; heat loss coefficient, irradiance, and ambient temperature. A simulated thermal efficiency was validated using experimental results by comparing the calculated heat removal factor. The validated methodology was then applied to five different inlet configurations of a header–riser collector. The most efficient designs had uniform flow through the risers. The worst performing configurations had low flow rates in the risers that led to high surface temperatures and poor thermal efficiency. The calculated heat removal factor differed by between 4.2% for the serpentine model and 12.1% for the header–riser. The discrepancies were attributed to differences in thermal contact between plate and tubes in the simulated and actual design.
- 17 July 2017
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 139 (5)
Computational Fluid Dynamics Simulation and Experimental Study of Key Design Parameters of Solar Thermal Collectors
Numerical simulation enables the optimization of a solar collector without the expense of building prototypes. This study details an approach using computational fluid dynamics (CFD) to simulate the performance of a solar thermal collector. Inputs to the simulation include; heat loss coefficient, irradiance, and ambient temperature. A simulated thermal efficiency was validated using experimental results by comparing the calculated heat removal factor. The validated methodology was then applied to five different inlet configurations of a header–riser collector. The most efficient designs had uniform flow through the risers. The worst performing configurations had low flow rates in the risers that led to high surface temperatures and poor thermal efficiency. The calculated heat removal factor differed by between 4.2% for the serpentine model and 12.1% for the header–riser. The discrepancies were attributed to differences in thermal contact between plate and tubes in the simulated and actual design.
- Open Access
- 1 March 2016
- Published by AIP Publishing in AIP Advances
- Vol. 6 (3) , 035011
Enhancing the thermal conductivity of ethylene-vinyl acetate (EVA) in a photovoltaic thermal collector
Samples of Ethylene-Vinyl Acetate (EVA) were doped with particles of Boron Nitride (BN) in concentrations ranging from 0-60% w/w. Thermal conductivity was measured using a Differential Scanning Calorimetery (DSC) technique. The thermal conductivity of parent EVA was increased from 0.24W/m ⋅ K to 0.80W/m ⋅ K for the 60% w/w sample. Two PV laminates were made; one using the parent EVA the other using EVA doped with 50% BN. When exposed to a one directional heat flux the doped laminate was, on average, 6% cooler than the standard laminate. A finite difference model had good agreement with experimental results and showed that the use of 60% BN composite achieved a PV performance increase of 0.3% compared to the standard laminate.
- 1 March 2016
- Published by AIP Publishing in AIP Advances
- Vol. 6 (3) , 035011
Open AccessEnhancing the thermal conductivity of ethylene-vinyl acetate (EVA) in a photovoltaic thermal collector
Samples of Ethylene-Vinyl Acetate (EVA) were doped with particles of Boron Nitride (BN) in concentrations ranging from 0-60% w/w. Thermal conductivity was measured using a Differential Scanning Calorimetery (DSC) technique. The thermal conductivity of parent EVA was increased from 0.24W/m ⋅ K to 0.80W/m ⋅ K for the 60% w/w sample. Two PV laminates were made; one using the parent EVA the other using EVA doped with 50% BN. When exposed to a one directional heat flux the doped laminate was, on average, 6% cooler than the standard laminate. A finite difference model had good agreement with experimental results and showed that the use of 60% BN composite achieved a PV performance increase of 0.3% compared to the standard laminate.
- Open Access
- 30 June 2015
- Published by Wiley in Energy Science & Engineering
- Vol. 3 (4) , 310-326
Performance testing of thermal and photovoltaic thermal solar collectors
This work details a methodology to characterize the performance of solar thermal and photovoltaic thermal (PVT) collectors using an indoor solar simulator. In this study, several cases have been compared to show that the methodology can be used to extract fundamental performance characteristics from a solar collector. In the first case, a serpentine collector was compared against a header riser collector using the same mass flow rate. It was found that the header riser was less efficient, with a 34% increase in the overall loss coefficient. The experimental results were compared with commonly used empirical models and showed a close agreement. In the second case, the impact on performance of using a polycarbonate cover is presented. The results show that the optical efficiency of the collector is reduced by 12% when using a cover; however, because the loss coefficient is reduced by 53%, the covered collector performs better when there is a large temperature difference between the absorber and the ambient. The third case investigates the combined performance of a PVT collector, that produces both heat and electricity from a single device. By placing photovoltaic (PV) laminates on top of the serpentine absorber, the thermal efficiency is reduced by 15%. When electricity is generated by laminates, the thermal efficiency is reduced by a further 3.5%; this drop in thermal efficiency is a result of the incident radiation producing electricity before reaching the thermal absorber. The combined efficiency of the PVT collectors was compared at controlled inlet temperatures. The serpentine design had the highest combined efficiency of 61% with 8% electricity at the lowest inlet temperature (21°C). The dominant form of loss in the PVT system is temperature driven; as the thermal efficiency decreases, electricity generation makes up a larger percentage of the combined output. This study highlights the potential for manufacturers of bespoke thermal absorbers and PV devices to combine their products into a single PVT device that could achieve improved efficiency over a given roof area.
- 30 June 2015
- Published by Wiley in Energy Science & Engineering
- Vol. 3 (4) , 310-326
Open AccessPerformance testing of thermal and photovoltaic thermal solar collectors
This work details a methodology to characterize the performance of solar thermal and photovoltaic thermal (PVT) collectors using an indoor solar simulator. In this study, several cases have been compared to show that the methodology can be used to extract fundamental performance characteristics from a solar collector. In the first case, a serpentine collector was compared against a header riser collector using the same mass flow rate. It was found that the header riser was less efficient, with a 34% increase in the overall loss coefficient. The experimental results were compared with commonly used empirical models and showed a close agreement. In the second case, the impact on performance of using a polycarbonate cover is presented. The results show that the optical efficiency of the collector is reduced by 12% when using a cover; however, because the loss coefficient is reduced by 53%, the covered collector performs better when there is a large temperature difference between the absorber and the ambient. The third case investigates the combined performance of a PVT collector, that produces both heat and electricity from a single device. By placing photovoltaic (PV) laminates on top of the serpentine absorber, the thermal efficiency is reduced by 15%. When electricity is generated by laminates, the thermal efficiency is reduced by a further 3.5%; this drop in thermal efficiency is a result of the incident radiation producing electricity before reaching the thermal absorber. The combined efficiency of the PVT collectors was compared at controlled inlet temperatures. The serpentine design had the highest combined efficiency of 61% with 8% electricity at the lowest inlet temperature (21°C). The dominant form of loss in the PVT system is temperature driven; as the thermal efficiency decreases, electricity generation makes up a larger percentage of the combined output. This study highlights the potential for manufacturers of bespoke thermal absorbers and PV devices to combine their products into a single PVT device that could achieve improved efficiency over a given roof area.