Paula García-Barquín
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Paula García-Barquín has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Jose Ignacio Bilbao
Interventional Radiology, Clinica Universidad de Navarra, Pamplona, Spain
2 shared publications A. Quílez
Departamento de Radiología, Clínica Universidad de Navarra, Pamplona (Navarra), España
1 shared publicationAgustín España Alonso
Dermatology Service, Clinica Universidad de Navarra, Pamplona, Spain
1 shared publication- Alberto Benito
IdisNA, Clínica Universidad de Navarra, Avenida Pio XII, 36, 31008, Pamplona, Navarra, Spain
1 shared publication - Alejandro Fernandez-Montero
University of Navarra
1 shared publication Arlette Elizalde
Service of Radiology, Clínica Universidad de Navarra, Pamplona, Spain
1 shared publication
Latest Publications
- 24 January 2025
- Published by Elsevier in Radiología (English Edition)
- Vol. 67 (1) , 61-73
The role of contrast-enhanced ultrasound in the evaluation of focal splenic lesions
- 24 January 2025
- Published by Elsevier in Radiología (English Edition)
- Vol. 67 (1) , 61-73
The role of contrast-enhanced ultrasound in the evaluation of focal splenic lesions
- Open Access
- 29 June 2017
- Published by Springer Nature in European Radiology Experimental
- Vol. 1 (1) , 1-7
Evaluation of the rabbit liver by direct portography and contrast-enhanced computed tomography: anatomical variations of the portal system and hepatic volume quantification
The study was aimed at: (1) describing the incidence of anatomic variations of the portal system in the rabbit using direct portography; and (2) estimating the liver volume and caudate lobe volume by using contrast-enhanced computed tomography (CECT) in the same animal model. Forty-six New Zealand white rabbits were included. All of them underwent direct portography and unenhanced CECT. Conventional liver rabbit portal system anatomy (type 1) consisted of the bifurcation of the main portal vein (MPV) into the right portal vein (RPV) and left portal vein (LPV), which subsequently divided into medial left portal vein and lateral left portal vein. Trifurcation of the LPV was considered type 2. The LPV that divides into four smaller branches was classified as type 3. Other configurations of the portal system, including particular cases of MPV branching, were grouped as type 4. Liver lobes were manually segmented. The incidence of each type of portal system anatomy was: type 1, 67.4%; type 2, 15.2%; type 3, 13.0%); and type 4, 4.3%. The mean volume of the caudate lobe was 19.1 ml ± 5.7 ml and of the cranial lobes it was 66.7 ml ± 13.7 ml, and the total liver volume was 85.7 ml ± 16.7 ml. In New Zealand white rabbits, type 1 is the prevalent type of portal system, liver volume is about 86 ml, and the caudate and cranial lobes are separated. This information could be important when planning experimental rabbit liver procedures.
- 29 June 2017
- Published by Springer Nature in European Radiology Experimental
- Vol. 1 (1) , 1-7
Open AccessEvaluation of the rabbit liver by direct portography and contrast-enhanced computed tomography: anatomical variations of the portal system and hepatic volume quantification
The study was aimed at: (1) describing the incidence of anatomic variations of the portal system in the rabbit using direct portography; and (2) estimating the liver volume and caudate lobe volume by using contrast-enhanced computed tomography (CECT) in the same animal model. Forty-six New Zealand white rabbits were included. All of them underwent direct portography and unenhanced CECT. Conventional liver rabbit portal system anatomy (type 1) consisted of the bifurcation of the main portal vein (MPV) into the right portal vein (RPV) and left portal vein (LPV), which subsequently divided into medial left portal vein and lateral left portal vein. Trifurcation of the LPV was considered type 2. The LPV that divides into four smaller branches was classified as type 3. Other configurations of the portal system, including particular cases of MPV branching, were grouped as type 4. Liver lobes were manually segmented. The incidence of each type of portal system anatomy was: type 1, 67.4%; type 2, 15.2%; type 3, 13.0%); and type 4, 4.3%. The mean volume of the caudate lobe was 19.1 ml ± 5.7 ml and of the cranial lobes it was 66.7 ml ± 13.7 ml, and the total liver volume was 85.7 ml ± 16.7 ml. In New Zealand white rabbits, type 1 is the prevalent type of portal system, liver volume is about 86 ml, and the caudate and cranial lobes are separated. This information could be important when planning experimental rabbit liver procedures.
- 30 March 2017
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 28 (6) , 877-885
Percutaneous CT–Guided Sympathicolysis with Radiofrequency for the Treatment of Palmar Hyperhidrosis
- 30 March 2017
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 28 (6) , 877-885
Percutaneous CT–Guided Sympathicolysis with Radiofrequency for the Treatment of Palmar Hyperhidrosis
- 12 November 2016
- Published by SAGE Publications in Acta Radiologica
- Vol. 58 (6) , 645-651
The effect of the amount of peritumoral adipose tissue in the detection of additional tumors with digital breast tomosynthesis and ultrasound
Digital breast tomosynthesis (DBT) and ultrasound (US) can detect additional cancers after negative mammography. However, not all cancers are visible by both techniques. To study the role of the amount of peritumoral fat in the detection of additional cancers with DBT or US. One reader retrospectively reviewed 142 breast cancers in 109 women who underwent mammography, DBT, US, and magnetic resonance imaging (MRI). Two readers in consensus evaluated the additional cancers detected by US, DBT, or MRI, and classified them into four groups according to the amount of peritumoral adipose tissue: group I, >75% of peritumoral fat; group II, 50–74%; group III, 25–49%, and group IV, 0–24%. The detection of additional cancers by US and DBT with respect to the other imaging techniques was evaluated. Seventy-eight cancers were detected by mammography and the remaining 64 cancers were detected by DBT, US, or MRI. US and DBT detected 46 (71.8%) and 25 (39.06%) additional tumors, respectively. Statistical significance was only found in group IV (P < 0.01). US detected more tumors than DBT in lesions surrounded by a small amount of fat. No significant differences were found between US and DBT in the detection of additional cancers in the other groups.
- 12 November 2016
- Published by SAGE Publications in Acta Radiologica
- Vol. 58 (6) , 645-651
The effect of the amount of peritumoral adipose tissue in the detection of additional tumors with digital breast tomosynthesis and ultrasound
Digital breast tomosynthesis (DBT) and ultrasound (US) can detect additional cancers after negative mammography. However, not all cancers are visible by both techniques. To study the role of the amount of peritumoral fat in the detection of additional cancers with DBT or US. One reader retrospectively reviewed 142 breast cancers in 109 women who underwent mammography, DBT, US, and magnetic resonance imaging (MRI). Two readers in consensus evaluated the additional cancers detected by US, DBT, or MRI, and classified them into four groups according to the amount of peritumoral adipose tissue: group I, >75% of peritumoral fat; group II, 50–74%; group III, 25–49%, and group IV, 0–24%. The detection of additional cancers by US and DBT with respect to the other imaging techniques was evaluated. Seventy-eight cancers were detected by mammography and the remaining 64 cancers were detected by DBT, US, or MRI. US and DBT detected 46 (71.8%) and 25 (39.06%) additional tumors, respectively. Statistical significance was only found in group IV (P < 0.01). US detected more tumors than DBT in lesions surrounded by a small amount of fat. No significant differences were found between US and DBT in the detection of additional cancers in the other groups.
- 17 June 2016
- Published by Elsevier in Radiologia
- Vol. 58 (6) , 435-443
Hallazgos de angiografía por tomografía computarizada de la mediólisis arterial segmentaria
- 17 June 2016
- Published by Elsevier in Radiologia
- Vol. 58 (6) , 435-443
Hallazgos de angiografía por tomografía computarizada de la mediólisis arterial segmentaria