Elshad Guliyev
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Elshad Guliyev has a total of 85 co-authors. Here are the top co-authors by number of shared publications:
- Ivo W. Rangelow
Department of Micro- and Nanoelectronical Systems, Technische Universität Ilmenau, Ehrenbergstraße 29, 98693 Ilmenau, Germany
17 shared publications Tzvetan Ivanov
Ilmenau Univ. of Technology (Germany)
14 shared publicationsAhmad Ahmad
Nano analytik GmbH (Germany)
12 shared publicationsAlexander Reum
Nano analytik GmbH (Germany)
10 shared publications- Claudia Lenk
Technische Universität Ilmenau
9 shared publications Mathias Holz
Nano analytik GmbH (Germany)
9 shared publications
Latest Publications
- 26 March 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10959, 79
Parallel active cantilever AFM tool for high-throughput inspection and metrology
Atomic Force Microscopy (AFM) is a capable to provide high resolution CD-metrology and precise defects analysis on large wafers, masks or displays. However, AFM is not enough productive for high-throughput industrial uses. Standard single probe AFMs are showing low throughput as a serial imaging tools. The use of an array of four cantilevers as a Quattro-Array results in affective speed of 6 to 10 mm/s. An image size of 0.5mm x 0.2mm is achieved employing a piezoelectric positioner with a scan range of 200μm x 200μm and a resolution of 0.25nm (x,y) and 0.2nm (z), respectively. These capabilities are qualifying the Quattro-cantilever array system as fastest tool for. In this paper we present new results obtained with our Quattro-AFM high-throughput parallel SPM system that exhibits two key advances that are required for a successful deployment of SPM in time-efficient metrology, defect analysis and mask inspection.
- 26 March 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10959, 79
Parallel active cantilever AFM tool for high-throughput inspection and metrology
Atomic Force Microscopy (AFM) is a capable to provide high resolution CD-metrology and precise defects analysis on large wafers, masks or displays. However, AFM is not enough productive for high-throughput industrial uses. Standard single probe AFMs are showing low throughput as a serial imaging tools. The use of an array of four cantilevers as a Quattro-Array results in affective speed of 6 to 10 mm/s. An image size of 0.5mm x 0.2mm is achieved employing a piezoelectric positioner with a scan range of 200μm x 200μm and a resolution of 0.25nm (x,y) and 0.2nm (z), respectively. These capabilities are qualifying the Quattro-cantilever array system as fastest tool for. In this paper we present new results obtained with our Quattro-AFM high-throughput parallel SPM system that exhibits two key advances that are required for a successful deployment of SPM in time-efficient metrology, defect analysis and mask inspection.
- 30 October 2018
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 36 (6) , 06JL06
Field-emission scanning probe lithography tool for 150 mm wafer
The development of next nodes of nano-electronic devices requires mask-less techniques for fast prototyping and analysis of ultimately down-scaled devices or for fabrication of templates for nanoimprint based high-volume manufacturing. Moreover, the atomic force microscopy (AFM) of large surfaces with acceptable speed becomes an issue with the introduction of large-sized wafers. The authors have designed an AFM system which is capable of field-emission scanning probe lithography on 150 mm wafers providing superior stitching accuracy better than 3 nm. The system is also providing noncontact, high-resolution 3D imaging employing active probes (i.e., piezoresistive self-sensing and thermo-mechanically self-actuated probes) and capable to operate with an array of four cantilevers. A high-precision X-Y-θ stage with 10 nm positioning accuracy and with 360° rotation capability enables the highest placement precision and cost effective large scanning field imaging.
- 30 October 2018
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 36 (6) , 06JL06
Field-emission scanning probe lithography tool for 150 mm wafer
The development of next nodes of nano-electronic devices requires mask-less techniques for fast prototyping and analysis of ultimately down-scaled devices or for fabrication of templates for nanoimprint based high-volume manufacturing. Moreover, the atomic force microscopy (AFM) of large surfaces with acceptable speed becomes an issue with the introduction of large-sized wafers. The authors have designed an AFM system which is capable of field-emission scanning probe lithography on 150 mm wafers providing superior stitching accuracy better than 3 nm. The system is also providing noncontact, high-resolution 3D imaging employing active probes (i.e., piezoresistive self-sensing and thermo-mechanically self-actuated probes) and capable to operate with an array of four cantilevers. A high-precision X-Y-θ stage with 10 nm positioning accuracy and with 360° rotation capability enables the highest placement precision and cost effective large scanning field imaging.
- 25 October 2018
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 36 (6) , 06JL03
Experimental study of field emission from ultrasharp silicon, diamond, GaN, and tungsten tips in close proximity to the counter electrode
The patterning process in field-emission scanning probe lithography (FE-SPL), a high-resolution and cost-effective method for nanofabrication, is based on the field emission of electrons from ultrasharp tips in close proximity to a sample (distances below 100 nm). Thereby, the emitted electrons expose directly an ultrathin resist film. The field enhancement at the tip apex is crucial for the field emission current, which follows the Fowler–Nordheim theory. Despite the success of FE-SPL in nanofabrication, systematic experimental studies of the field-emission process, including the determination of the tip radius and tip-to-sample distance during the measurement, for these small tip-to-sample distances and different tip materials are lacking. To resolve this issue, experimental measurements of the field-emission current for tip–sample proximity distances below 100 nm were performed. For this purpose, the developed AFM in SEM system was modified,1,2 which enables one to monitor the tip–sample distance with a high accuracy using SEM while simultaneously recording the field-emission current. The authors present experimental results of the dependence of the field-emission current on the tip shape, tip material, applied voltage, and tip–sample distance. Therefore, the emission characteristics of silicon, diamond, GaN, and tungsten tips are shown. The knowledge about the field-emission process for small tip-to-sample distances will help to understand and improve the current FE-SPL, regarding also the choice of tip material. Furthermore, these measurements enable the detailed comparison with current FE models beyond state-of-the-art since all necessary parameters (voltage, current, tip diameter, and tip-to-sample distance) could be measured and controlled during the FE experiment due to the unique experimental system.
- 25 October 2018
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 36 (6) , 06JL03
Experimental study of field emission from ultrasharp silicon, diamond, GaN, and tungsten tips in close proximity to the counter electrode
The patterning process in field-emission scanning probe lithography (FE-SPL), a high-resolution and cost-effective method for nanofabrication, is based on the field emission of electrons from ultrasharp tips in close proximity to a sample (distances below 100 nm). Thereby, the emitted electrons expose directly an ultrathin resist film. The field enhancement at the tip apex is crucial for the field emission current, which follows the Fowler–Nordheim theory. Despite the success of FE-SPL in nanofabrication, systematic experimental studies of the field-emission process, including the determination of the tip radius and tip-to-sample distance during the measurement, for these small tip-to-sample distances and different tip materials are lacking. To resolve this issue, experimental measurements of the field-emission current for tip–sample proximity distances below 100 nm were performed. For this purpose, the developed AFM in SEM system was modified,1,2 which enables one to monitor the tip–sample distance with a high accuracy using SEM while simultaneously recording the field-emission current. The authors present experimental results of the dependence of the field-emission current on the tip shape, tip material, applied voltage, and tip–sample distance. Therefore, the emission characteristics of silicon, diamond, GaN, and tungsten tips are shown. The knowledge about the field-emission process for small tip-to-sample distances will help to understand and improve the current FE-SPL, regarding also the choice of tip material. Furthermore, these measurements enable the detailed comparison with current FE models beyond state-of-the-art since all necessary parameters (voltage, current, tip diameter, and tip-to-sample distance) could be measured and controlled during the FE experiment due to the unique experimental system.
- 25 October 2018
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 36 (6) , 06J102
Atomic force microscope integrated with a scanning electron microscope for correlative nanofabrication and microscopy
More than 40 years after its invention, the atomic force microscopy (AFM) can be integrated with scanning electron microscope (SEM) instruments as an increasingly capable and productive characterization tool with sub-nanometer spatial resolution. The authors have designed and developed an AFM instrument capable to be integrated into any SEM or in a combination of SEM with a focused ion-beam (FIB) tool. The combination of two or more different types of techniques like SEM, energy dispersive x-ray spectroscopy, and AFM is called correlative microscopy because analytical information from the same place of the sample can be obtained and correlated. For the first time, they introduced to the SEM/FIB tool correlative nanofabrication methods like field-emission scanning probe lithography, tip-based electron beam induced deposition, and nanomachining. The combination of all these methods provides a completely new nanotechnology instrument, which should be seen as a tool for correlative nanofabrication and microscopy. Thus, it provides for the first time the capabilities of a stand-alone instrument with the capabilities of nondestructive three-dimensional tip-based metrology and nanofabrication into the combined SEM/FIB tool. In this article, the authors describe all these methods in detail and present a brief example of the results obtained. They demonstrate that the self-sensing, self-actuating cantilevers (called active cantilevers) equipped with Diamond tip are a versatile toolkit for fast imaging and emerging nanofabrication. The AFM integrated into SEM is using active cantilevers that can characterize and generate nanostructures all in situ without the need to break-vacuum or contaminate the sample.
- 25 October 2018
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 36 (6) , 06J102
Atomic force microscope integrated with a scanning electron microscope for correlative nanofabrication and microscopy
More than 40 years after its invention, the atomic force microscopy (AFM) can be integrated with scanning electron microscope (SEM) instruments as an increasingly capable and productive characterization tool with sub-nanometer spatial resolution. The authors have designed and developed an AFM instrument capable to be integrated into any SEM or in a combination of SEM with a focused ion-beam (FIB) tool. The combination of two or more different types of techniques like SEM, energy dispersive x-ray spectroscopy, and AFM is called correlative microscopy because analytical information from the same place of the sample can be obtained and correlated. For the first time, they introduced to the SEM/FIB tool correlative nanofabrication methods like field-emission scanning probe lithography, tip-based electron beam induced deposition, and nanomachining. The combination of all these methods provides a completely new nanotechnology instrument, which should be seen as a tool for correlative nanofabrication and microscopy. Thus, it provides for the first time the capabilities of a stand-alone instrument with the capabilities of nondestructive three-dimensional tip-based metrology and nanofabrication into the combined SEM/FIB tool. In this article, the authors describe all these methods in detail and present a brief example of the results obtained. They demonstrate that the self-sensing, self-actuating cantilevers (called active cantilevers) equipped with Diamond tip are a versatile toolkit for fast imaging and emerging nanofabrication. The AFM integrated into SEM is using active cantilevers that can characterize and generate nanostructures all in situ without the need to break-vacuum or contaminate the sample.
- 19 March 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10584, 1058406
Field-emission scanning probe lithography with self-actuating and self-sensing cantilevers for devices with single digit nanometer dimensions
Cost-effective generation of single-digit nano-lithographic features could be the way by which novel nanoelectronic devices, as single electron transistors combined with sophisticated CMOS integrated circuits, can be obtained. The capabilities of Field-Emission Scanning Probe Lithography (FE-SPL) and reactive ion etching (RIE) at cryogenic temperature open up a route to overcome the fundamental size limitations in nanofabrication. FE-SPL employs Fowler-Nordheim electron emission from the tip of a scanning probe in ambient conditions. The energy of the emitted electrons (<100 eV) is close to the lithographically relevant chemical excitations of the resist, thus strongly reducing proximity effects. The use of active, i.e. self-sensing and self-actuated, cantilevers as probes for FE-SPL leads to several promising performance benefits. These include: (1) Closed-loop lithography including pre-imaging, overlay alignment, exposure, and post-imaging for feature inspection; (2) Sub-5-nm lithographic resolution with sub-nm line edge roughness; (3) High overlay alignment accuracy; (4) Relatively low costs of ownership, since no vacuum is needed, and ease-of-use. Thus, FE-SPL is a promising tool for rapid nanoscale prototyping and fabrication of high resolution nanoimprint lithography templates. To demonstrate its capabilities we applied FE-SPL and RIE to fabricate single electron transistors (SET) targeted to operate at room temperature. Electrical characterization of these SET confirmed that the smallest functional structures had a diameter of only 1.8 nanometers. Devices at single digit nano-dimensions contain only a few dopant atoms and thus, these might be used to store and process quantum information by employing the states of individual atoms.
- 19 March 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10584, 1058406
Field-emission scanning probe lithography with self-actuating and self-sensing cantilevers for devices with single digit nanometer dimensions
Cost-effective generation of single-digit nano-lithographic features could be the way by which novel nanoelectronic devices, as single electron transistors combined with sophisticated CMOS integrated circuits, can be obtained. The capabilities of Field-Emission Scanning Probe Lithography (FE-SPL) and reactive ion etching (RIE) at cryogenic temperature open up a route to overcome the fundamental size limitations in nanofabrication. FE-SPL employs Fowler-Nordheim electron emission from the tip of a scanning probe in ambient conditions. The energy of the emitted electrons (<100 eV) is close to the lithographically relevant chemical excitations of the resist, thus strongly reducing proximity effects. The use of active, i.e. self-sensing and self-actuated, cantilevers as probes for FE-SPL leads to several promising performance benefits. These include: (1) Closed-loop lithography including pre-imaging, overlay alignment, exposure, and post-imaging for feature inspection; (2) Sub-5-nm lithographic resolution with sub-nm line edge roughness; (3) High overlay alignment accuracy; (4) Relatively low costs of ownership, since no vacuum is needed, and ease-of-use. Thus, FE-SPL is a promising tool for rapid nanoscale prototyping and fabrication of high resolution nanoimprint lithography templates. To demonstrate its capabilities we applied FE-SPL and RIE to fabricate single electron transistors (SET) targeted to operate at room temperature. Electrical characterization of these SET confirmed that the smallest functional structures had a diameter of only 1.8 nanometers. Devices at single digit nano-dimensions contain only a few dopant atoms and thus, these might be used to store and process quantum information by employing the states of individual atoms.
- 31 January 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10456, 66
Single nano-digit and closed-loop scanning probe lithography for manufacturing of electronic and optical nanodevices
Next-generation electronic and optical devices demand high-resolution patterning techniques and high-throughput fabrication. Thereby Field-Emission Scanning Probe Lithography (FE-SPL) is a direct writing method that provides high resolution, excellent overlay alignment accuracy and high fidelity nanopatterns. As a demonstration of the patterning technology, single-electron transistors as well as split ring electromagnetic resonators are fabricated through a combination of FE-SPL and plasma etching at cryogenic temperatures.
- 31 January 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10456, 66
Single nano-digit and closed-loop scanning probe lithography for manufacturing of electronic and optical nanodevices
Next-generation electronic and optical devices demand high-resolution patterning techniques and high-throughput fabrication. Thereby Field-Emission Scanning Probe Lithography (FE-SPL) is a direct writing method that provides high resolution, excellent overlay alignment accuracy and high fidelity nanopatterns. As a demonstration of the patterning technology, single-electron transistors as well as split ring electromagnetic resonators are fabricated through a combination of FE-SPL and plasma etching at cryogenic temperatures.
- 26 December 2016
- Published by Springer Nature in Applied Physics A
- Vol. 123 (1) , 1-12
Scanning probe-based high-accuracy overlay alignment concept for lithography applications
- 26 December 2016
- Published by Springer Nature in Applied Physics A
- Vol. 123 (1) , 1-12
Scanning probe-based high-accuracy overlay alignment concept for lithography applications
- 1 November 2016
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 34 (6) , 06KM03
Large area fast-AFM scanning with active “Quattro” cantilever arrays
In this work, the fabrication and operation of an active parallel cantilever device integrating four self-sensing and self-actuating probes in an array is presented. The so called “Quattro” cantilever system is controlled by a multichannel field programmable gate array (FPGA) controller. The integrated cantilever devices are fabricated on the basis of a silicon-on-insulator wafer using surface micromachining and gas chopping plasma-etching processes [I. W. Rangelow, J. Vac. Sci. Technol., A 21, 1550 (2003)]. The unique design of the active cantilever probes provides both patterning and readout capabilities [Kaestner et al., J. Micro-Nanolithogr. MEMS 14, 031202 (2015)]. The thermomechanical actuation allows the individually operation of each cantilever in static and dynamic modes. This enables a simultaneous atomic force microscopy operation of all cantilevers in an array, while the piezoresistive read-out of the cantilever bending routinely ensures atomic resolution at a high imaging speed. The scanning probe lithography capabilities of the active cantilevers are based on the utilization of a Fowler–Nordheim field emission process of low-energy electrons (20–50 eV) for direct writing maskless lithography. The cantilever in the Quattro active cantilever array have a pitch of 125 μm (tip-to-tip distance), which allows an image size of 0.5 × 0.2 mm to be acquired within a single scan with 0.2 nm resolution in the vertical direction. Using parallel imaging, an effective scanning speed of 5.6 mm/s is achieved. The multichannel, scalable controller architecture allows four FPGA channels to scan and collect data simultaneously. A data buffer of 128 Mbits for a single frame of 4096 × 1024 pixels is applied. The designed data transfer system allows a packet size of 128 pixels to be transmitted within less than 10 μs, respectively. Thus, the entire image frame is transferred in less than 280 ms, which exceeds the required throughput in the practical cases like critical dimension-metrology and inspection. In this article, the authors are presenting the concept of the system, which combines imaging, metrology, and lithography capabilities with a low-cost of ownership. In this context, the authors are investigating the throughput capability, reproducibility, resolution, and positioning accuracy of the Quattro active cantilever system.
- 1 November 2016
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 34 (6) , 06KM03
Large area fast-AFM scanning with active “Quattro” cantilever arrays
In this work, the fabrication and operation of an active parallel cantilever device integrating four self-sensing and self-actuating probes in an array is presented. The so called “Quattro” cantilever system is controlled by a multichannel field programmable gate array (FPGA) controller. The integrated cantilever devices are fabricated on the basis of a silicon-on-insulator wafer using surface micromachining and gas chopping plasma-etching processes [I. W. Rangelow, J. Vac. Sci. Technol., A 21, 1550 (2003)]. The unique design of the active cantilever probes provides both patterning and readout capabilities [Kaestner et al., J. Micro-Nanolithogr. MEMS 14, 031202 (2015)]. The thermomechanical actuation allows the individually operation of each cantilever in static and dynamic modes. This enables a simultaneous atomic force microscopy operation of all cantilevers in an array, while the piezoresistive read-out of the cantilever bending routinely ensures atomic resolution at a high imaging speed. The scanning probe lithography capabilities of the active cantilevers are based on the utilization of a Fowler–Nordheim field emission process of low-energy electrons (20–50 eV) for direct writing maskless lithography. The cantilever in the Quattro active cantilever array have a pitch of 125 μm (tip-to-tip distance), which allows an image size of 0.5 × 0.2 mm to be acquired within a single scan with 0.2 nm resolution in the vertical direction. Using parallel imaging, an effective scanning speed of 5.6 mm/s is achieved. The multichannel, scalable controller architecture allows four FPGA channels to scan and collect data simultaneously. A data buffer of 128 Mbits for a single frame of 4096 × 1024 pixels is applied. The designed data transfer system allows a packet size of 128 pixels to be transmitted within less than 10 μs, respectively. Thus, the entire image frame is transferred in less than 280 ms, which exceeds the required throughput in the practical cases like critical dimension-metrology and inspection. In this article, the authors are presenting the concept of the system, which combines imaging, metrology, and lithography capabilities with a low-cost of ownership. In this context, the authors are investigating the throughput capability, reproducibility, resolution, and positioning accuracy of the Quattro active cantilever system.
- Open Access
- 1 November 2016
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 34 (6) , 06K202
Pattern-generation and pattern-transfer for single-digit nano devices
Single-electron devices operating at room temperature require sub-5 nm quantum dots having tunnel junctions of comparable dimensions. Further development in nanoelectronics depends on the capability to generate mesoscopic structures and interfacing these with complementary metal–oxide–semiconductor devices in a single system. The authors employ a combination of two novel methods of fabricating room temperature silicon single-electron transistors (SETs), Fowler–Nordheim scanning probe lithography (F-N SPL) with active cantilevers and cryogenic reactive ion etching followed by pattern-dependent oxidation. The F-N SPL employs a low energy electron exposure of 5–10 nm thick high-resolution molecular resist (Calixarene) resulting in single nanodigit lithographic performance [Rangelow et al., Proc. SPIE 7637, 76370V (2010)]. The followed step of pattern transfer into silicon becomes very challenging because of the extremely low resist thickness, which limits the etching depth. The authors developed a computer simulation code to simulate the reactive ion etching at cryogenic temperatures (−120 °C). In this article, the authors present the alliance of all these technologies used for the manufacturing of SETs capable to operate at room temperatures.
- 1 November 2016
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 34 (6) , 06K202
Open AccessPattern-generation and pattern-transfer for single-digit nano devices
Single-electron devices operating at room temperature require sub-5 nm quantum dots having tunnel junctions of comparable dimensions. Further development in nanoelectronics depends on the capability to generate mesoscopic structures and interfacing these with complementary metal–oxide–semiconductor devices in a single system. The authors employ a combination of two novel methods of fabricating room temperature silicon single-electron transistors (SETs), Fowler–Nordheim scanning probe lithography (F-N SPL) with active cantilevers and cryogenic reactive ion etching followed by pattern-dependent oxidation. The F-N SPL employs a low energy electron exposure of 5–10 nm thick high-resolution molecular resist (Calixarene) resulting in single nanodigit lithographic performance [Rangelow et al., Proc. SPIE 7637, 76370V (2010)]. The followed step of pattern transfer into silicon becomes very challenging because of the extremely low resist thickness, which limits the etching depth. The authors developed a computer simulation code to simulate the reactive ion etching at cryogenic temperatures (−120 °C). In this article, the authors present the alliance of all these technologies used for the manufacturing of SETs capable to operate at room temperatures.
- 4 October 2016
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 34 (6) , 06KB01
Six-axis AFM in SEM with self-sensing and self-transduced cantilever for high speed analysis and nanolithography
Merging two state-of-the-art surface research techniques, in particular, atomic force microscopy (AFM) and scanning electron microscopy (SEM), within a single system is providing novel capabilities like direct visual feedback and life-monitoring of tip-induced nanoscale interactions. In addition, the combination of AFM and SEM accelerates nanoscale characterization and metrology development. Here, the concept and first results of a novel AFM-integration into a high resolution scanning electron microscope and focused ion beam system for nanoscale characterization is presented. In this context, a six-axis AFM system using self-sensing thermomechanically transduced active cantilever was developed and integrated. The design of the developed AFM-integration is described and its performance is demonstrated. Results from combined examinations applying fast AFM-methods and SEM-image fusion, AFM-SEM combined metrology verification, and three dimensional-visualization are shown. Simultaneous operation of SEM and AFM provides a fast navigation combined with sub-10 nm topographic image acquisition. Metrology application scenarios of combined studies are discussed, for example of MoS2 and diverse metrological test structures.
- 4 October 2016
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 34 (6) , 06KB01
Six-axis AFM in SEM with self-sensing and self-transduced cantilever for high speed analysis and nanolithography
Merging two state-of-the-art surface research techniques, in particular, atomic force microscopy (AFM) and scanning electron microscopy (SEM), within a single system is providing novel capabilities like direct visual feedback and life-monitoring of tip-induced nanoscale interactions. In addition, the combination of AFM and SEM accelerates nanoscale characterization and metrology development. Here, the concept and first results of a novel AFM-integration into a high resolution scanning electron microscope and focused ion beam system for nanoscale characterization is presented. In this context, a six-axis AFM system using self-sensing thermomechanically transduced active cantilever was developed and integrated. The design of the developed AFM-integration is described and its performance is demonstrated. Results from combined examinations applying fast AFM-methods and SEM-image fusion, AFM-SEM combined metrology verification, and three dimensional-visualization are shown. Simultaneous operation of SEM and AFM provides a fast navigation combined with sub-10 nm topographic image acquisition. Metrology application scenarios of combined studies are discussed, for example of MoS2 and diverse metrological test structures.