Lhoucine Oufni
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lhoucine Oufni has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
R. Rabi
6 shared publications- Mihail Secu
National Institute of Materials Physics, Atomiştilor 405A, 077125 Măgurele, Romania
3 shared publications N. Kayouh
3 shared publicationsO. AitMellal
3 shared publicationsA. Mounir
2 shared publicationsA. Tounsi
2 shared publications
Latest Publications
- 17 February 2026
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 141 (2)
Quantifying lung dose from inhaled radon progeny using computational fluid dynamics
- 17 February 2026
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 141 (2)
Quantifying lung dose from inhaled radon progeny using computational fluid dynamics
- 11 November 2025
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 240
Monte Carlo evaluation of the IEC 60601-2-44 wide-beam CTDI correction in diagnostic CT
- 11 November 2025
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 240
Monte Carlo evaluation of the IEC 60601-2-44 wide-beam CTDI correction in diagnostic CT
- 15 October 2025
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 227, 112257
Modeling radon progeny deposition and dose in human airways using CFD: Effects of respiratory patterns and environmental variables
- 15 October 2025
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 227, 112257
Modeling radon progeny deposition and dose in human airways using CFD: Effects of respiratory patterns and environmental variables
- 10 April 2025
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 140 (4) , 1-12
CFD modeling of radon progeny transport and deposition in the human respiratory tract
- 10 April 2025
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 140 (4) , 1-12
CFD modeling of radon progeny transport and deposition in the human respiratory tract
- Open Access
- 1 April 2025
- Published by EDP Sciences in Radioprotection
- Vol. 60 (2) , 208
Erratum for: Diagnostic reference levels for adult Computed Tomography at the University Hospital Center of Marrakech (Morocco)
Radioprotection, theoretical calculation of doses - radioactive fallout - biological effects of ionising radiation or radiobiology - experimental studies (dosimetry, reactor physics, radiochemistry), radiobiological risk management
- 1 April 2025
- Published by EDP Sciences in Radioprotection
- Vol. 60 (2) , 208
Open AccessErratum for: Diagnostic reference levels for adult Computed Tomography at the University Hospital Center of Marrakech (Morocco)
Radioprotection, theoretical calculation of doses - radioactive fallout - biological effects of ionising radiation or radiobiology - experimental studies (dosimetry, reactor physics, radiochemistry), radiobiological risk management
- Open Access
- 1 January 2025
- Published by EDP Sciences in Radioprotection
- Vol. 60 (1) , 44-49
Diagnostic reference levels for adult computed tomography at the University Hospital Center of Marrakech (Morocco)
In this research, the diagnostic reference level (DRL) for routine computer tomography (CT) exams at the Arrazi Hospital of the Mohammed VI University Hospital Center (Med VI UHC) in Marrakech, Morocco, was established. The DRL for routine CT scans was derived through prospective research. Based on recommendation for computing DRL by various international legal organisations, we took into account the CT Volume Dose Index CTDIvol (mGy) and the Dose-Length Product DLP (mGy.cm) as dosimetric quantities. The statistics calculated of the CTDIvol and DLP 75th percentiles were suggested as DRLs. The DRLs obtained for the head, chest-abdomen-pelvis (CAP), chest, and abdomen were 39 mGy, 8 mGy, 11 mGy, 9 mGy, and 1445 mGy.cm, 825 mGy.cm, 700 mGy.cm, and 788 mGy.cm, respectively. When compared to the published values, the DRLs found in the present search are more elevated.
- 1 January 2025
- Published by EDP Sciences in Radioprotection
- Vol. 60 (1) , 44-49
Open AccessDiagnostic reference levels for adult computed tomography at the University Hospital Center of Marrakech (Morocco)
In this research, the diagnostic reference level (DRL) for routine computer tomography (CT) exams at the Arrazi Hospital of the Mohammed VI University Hospital Center (Med VI UHC) in Marrakech, Morocco, was established. The DRL for routine CT scans was derived through prospective research. Based on recommendation for computing DRL by various international legal organisations, we took into account the CT Volume Dose Index CTDIvol (mGy) and the Dose-Length Product DLP (mGy.cm) as dosimetric quantities. The statistics calculated of the CTDIvol and DLP 75th percentiles were suggested as DRLs. The DRLs obtained for the head, chest-abdomen-pelvis (CAP), chest, and abdomen were 39 mGy, 8 mGy, 11 mGy, 9 mGy, and 1445 mGy.cm, 825 mGy.cm, 700 mGy.cm, and 788 mGy.cm, respectively. When compared to the published values, the DRLs found in the present search are more elevated.
- 2 January 2024
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 272, 107365
Computational analysis of radon progeny deposition patterns in the human respiratory system
- 2 January 2024
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 272, 107365
Computational analysis of radon progeny deposition patterns in the human respiratory system
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2814 (1)
Modeling of indoor radon concentration by using the MRT-Lattice Boltzmann in ventilated room
This paper treats monitoring and predicting the indoor radon activity concentration level in a ventilated room using the Lattice Boltzmann Method (LBM), which is a numerical technique derived from the kinetic theory for simulating fluid flows and modeling fluid physics. Four different configurations of ventilated square cavities have been investigated. The numerical results confirm that the indoor radon activity concentration is affected by the ventilation rate and the location of the outlet. Hence, excellent indoor air quality needs to decrease the indoor radon activity concentration, which requires increasing the ventilation rate and placing the air outlet in a suitable position.
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2814 (1)
Open AccessModeling of indoor radon concentration by using the MRT-Lattice Boltzmann in ventilated room
This paper treats monitoring and predicting the indoor radon activity concentration level in a ventilated room using the Lattice Boltzmann Method (LBM), which is a numerical technique derived from the kinetic theory for simulating fluid flows and modeling fluid physics. Four different configurations of ventilated square cavities have been investigated. The numerical results confirm that the indoor radon activity concentration is affected by the ventilation rate and the location of the outlet. Hence, excellent indoor air quality needs to decrease the indoor radon activity concentration, which requires increasing the ventilation rate and placing the air outlet in a suitable position.
- 4 June 2022
- Published by Elsevier in Optical Materials
- Vol. 129
Temperature-induced phase transition and tunable luminescence properties of Ce3+-Mn2+-Zr4+ tri-doped LaPO4 phosphor
- 4 June 2022
- Published by Elsevier in Optical Materials
- Vol. 129
Temperature-induced phase transition and tunable luminescence properties of Ce3+-Mn2+-Zr4+ tri-doped LaPO4 phosphor
- 5 January 2022
- Published by Springer Nature in Journal of Materials Science: Materials in Electronics
- Vol. 33 (7) , 4197-4210
Structural properties and near-infrared light from Ce3+/Nd3+-co-doped LaPO4 nanophosphors for solar cell applications
- 5 January 2022
- Published by Springer Nature in Journal of Materials Science: Materials in Electronics
- Vol. 33 (7) , 4197-4210
Structural properties and near-infrared light from Ce3+/Nd3+-co-doped LaPO4 nanophosphors for solar cell applications