William M. Holmes
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
William M. Holmes has a total of 126 co-authors. Here are the top co-authors by number of shared publications:
Antoine Vallatos
Glasgow Experimental MRI Centre, School of Neuroscience and Psychology, University of Glasgow, UK
4 shared publications- Haitham Al-Mubarak
Glasgow Experimental MRI Centre, Institute of Neuroscience and Psychology, University of Glasgow, Glasgow G12 8QQ, UK
4 shared publications Lindsay Gallagher
Institute of Neuroscience and Psychology, College of Medicine, Veterinary and Life Science, University of Glasgow, Glasgow, United Kingdom
4 shared publicationsChristopher McCabe
Glasgow Experimental MRI Centre (GEMRIC), Wellcome Surgical Institute, Institute of Neuroscience and Psychology, Garscube Estate, University of Glasgow, Glasgow, Scotland, G61 1QH, UK
3 shared publications- Lindsay Gallagher
Glasgow Experimental MRI Centre, Institute of Neuroscience and Psychology, University of Glasgow, G61 1QH, UK
3 shared publications - Anthony J. Chalmers
School of Cancer Sciences, University of Glasgow , Glasgow
2 shared publications
Latest Publications
- Open Access
A harmonized phantom MRI quality control framework identifies sources of longitudinal and multi-site variability
The shift towards open science in preclinical research requires high-quality, comparable data adhering to FAIR principles, yet rigorous quality assurance (QA) and quality control (QC) frameworks remain less established in preclinical magnetic resonance imaging (MRI) than in clinical imaging. To address this limitation, a multicenter study was conducted across 21 international laboratories using standardized commercial liquid phantoms for mouse and rat MRI setups and a harmonized acquisition protocol. Data processing was centralized using AIDAqc, an automated pipeline extracting quantitative metrics including signal-to-noise ratio (SNR), temporal SNR (tSNR), ghost-to-signal ratio (GSR), and motion-equivalent temporal instability, combined with five complementary outlier-detection algorithms. The evaluated datasets encompassed magnetic field strengths from 3.0 to 16.4 T and heterogeneous coil and acquisition configurations. In mouse phantom data, SNR and tSNR were significantly lower at 3 T than at 7 and 9.4 T, whereas artifact-related metrics did not differ significantly between field-strength groups. In rat phantom data, differences between field strengths were less pronounced. At 7 T, substantial dataset-specific differences were observed in anatomical and functional quality metrics, also among datasets using the similar coil configuration. Multicenter reference values for frequently represented 7 T configurations were established, including SNR/tSNR of 48 ± 3/48 ± 1 dB for mouse surface-coil datasets and 49 ± 3/44 ± 4 dB for rat 2 × 2 array-coil datasets. Longitudinal anatomical SNR showed generally low variability, whereas GSR was more variable across time. Automated outlier detection additionally identified transient acquisition instabilities that were not always apparent by visual inspection. Together, these findings show that field strength and nominal coil configuration alone do not adequately characterize MRI performance and support standardized, longitudinal phantom- based QC combined with automated analysis as a practical approach for improving the reliability, transparency, and interoperability of multicenter preclinical MRI data.
Open AccessA harmonized phantom MRI quality control framework identifies sources of longitudinal and multi-site variability
The shift towards open science in preclinical research requires high-quality, comparable data adhering to FAIR principles, yet rigorous quality assurance (QA) and quality control (QC) frameworks remain less established in preclinical magnetic resonance imaging (MRI) than in clinical imaging. To address this limitation, a multicenter study was conducted across 21 international laboratories using standardized commercial liquid phantoms for mouse and rat MRI setups and a harmonized acquisition protocol. Data processing was centralized using AIDAqc, an automated pipeline extracting quantitative metrics including signal-to-noise ratio (SNR), temporal SNR (tSNR), ghost-to-signal ratio (GSR), and motion-equivalent temporal instability, combined with five complementary outlier-detection algorithms. The evaluated datasets encompassed magnetic field strengths from 3.0 to 16.4 T and heterogeneous coil and acquisition configurations. In mouse phantom data, SNR and tSNR were significantly lower at 3 T than at 7 and 9.4 T, whereas artifact-related metrics did not differ significantly between field-strength groups. In rat phantom data, differences between field strengths were less pronounced. At 7 T, substantial dataset-specific differences were observed in anatomical and functional quality metrics, also among datasets using the similar coil configuration. Multicenter reference values for frequently represented 7 T configurations were established, including SNR/tSNR of 48 ± 3/48 ± 1 dB for mouse surface-coil datasets and 49 ± 3/44 ± 4 dB for rat 2 × 2 array-coil datasets. Longitudinal anatomical SNR showed generally low variability, whereas GSR was more variable across time. Automated outlier detection additionally identified transient acquisition instabilities that were not always apparent by visual inspection. Together, these findings show that field strength and nominal coil configuration alone do not adequately characterize MRI performance and support standardized, longitudinal phantom- based QC combined with automated analysis as a practical approach for improving the reliability, transparency, and interoperability of multicenter preclinical MRI data.
- Open Access
- 3 July 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (27) , eaec7011
Bio-integrated μBots with overtone ultrawideband magnetoelectric antennas for wireless telemetry
Implantable and wearable devices require antennas that are both miniaturized and efficient, yet conventional designs are constrained by narrow bandwidth and orientation sensitivity. We report overtone ultrawideband magnetoelectric (OUWB-ME) antennas that exploit higher-order acoustic modes in polished silicon substrates to achieve a 22.6-gigahertz −10-decibel bandwidth and overtone capability in the 3- to 4-gigahertz range. Packaged into “μBots,” these magnetoelectric heterostructures bonded with silver nanoparticle inks maintain stable operation under biological loading. In vitro assays confirm the biocompatibility of aluminum nitride and the protective role of parylene encapsulation for iron-gallium. Ex vivo rat and human tissues reshape transmission and reflection spectra, with reproducible frequency windows near 3.3 and 3.9 gigahertz. μBots enable real-time audiovisual telemetry using software-defined radios and exhibit compatibility with 7-tesla magnetic resonance imaging. By combining wideband response, robustness to misalignment, and biocompatible packaging, OUWB-ME μBots provide a scalable platform for wireless bio-integrated communication and telemetry.
- 3 July 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (27) , eaec7011
Open AccessBio-integrated μBots with overtone ultrawideband magnetoelectric antennas for wireless telemetry
Implantable and wearable devices require antennas that are both miniaturized and efficient, yet conventional designs are constrained by narrow bandwidth and orientation sensitivity. We report overtone ultrawideband magnetoelectric (OUWB-ME) antennas that exploit higher-order acoustic modes in polished silicon substrates to achieve a 22.6-gigahertz −10-decibel bandwidth and overtone capability in the 3- to 4-gigahertz range. Packaged into “μBots,” these magnetoelectric heterostructures bonded with silver nanoparticle inks maintain stable operation under biological loading. In vitro assays confirm the biocompatibility of aluminum nitride and the protective role of parylene encapsulation for iron-gallium. Ex vivo rat and human tissues reshape transmission and reflection spectra, with reproducible frequency windows near 3.3 and 3.9 gigahertz. μBots enable real-time audiovisual telemetry using software-defined radios and exhibit compatibility with 7-tesla magnetic resonance imaging. By combining wideband response, robustness to misalignment, and biocompatible packaging, OUWB-ME μBots provide a scalable platform for wireless bio-integrated communication and telemetry.
- 18 February 2025
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 119, 110361
Quantitative multiple boli arterial spin labeling
- 18 February 2025
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 119, 110361
Quantitative multiple boli arterial spin labeling
- Open Access
- 29 May 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-9
Application of diffusion weighted multiple boli ASL to a murine model of human African trypanosomiasis
Human African Trypanosomiasis (HAT) is a parasitic disease originating in sub-Saharan Africa. There is limited information about the changes in the blood brain barrier (BBB) during this infection. This study is the first to apply diffusion weighted ASL (DWASL) to examine changes in BBB impairment. No significant changes in water exchange across the BBB were found during the infection, even when a loss of barrier integrity was seen using Contrast Enhanced MRI (Gd-DTPA) during the late stage of the disease. Furthermore, using multiple boli ASL (mbASL), changes in cerebral blood flow (CBF) were found during the course of infection. Overall, this study highlights the need for further study of the BBB during HAT infection to understand the complex mechanisms behind impairment.
- 29 May 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-9
Open AccessApplication of diffusion weighted multiple boli ASL to a murine model of human African trypanosomiasis
Human African Trypanosomiasis (HAT) is a parasitic disease originating in sub-Saharan Africa. There is limited information about the changes in the blood brain barrier (BBB) during this infection. This study is the first to apply diffusion weighted ASL (DWASL) to examine changes in BBB impairment. No significant changes in water exchange across the BBB were found during the infection, even when a loss of barrier integrity was seen using Contrast Enhanced MRI (Gd-DTPA) during the late stage of the disease. Furthermore, using multiple boli ASL (mbASL), changes in cerebral blood flow (CBF) were found during the course of infection. Overall, this study highlights the need for further study of the BBB during HAT infection to understand the complex mechanisms behind impairment.
- Open Access
- 15 March 2023
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (3) , e0282955
The effect of a novel AQP4 facilitator, TGN-073, on glymphatic transport captured by diffusion MRI and DCE-MRI
The glymphatic system is a low resistance pathway, by which cerebrospinal fluid enters the brain parenchyma along perivascular spaces via AQP4 channels. It is hypothesised that the resulting convective flow of the interstitial fluid provides an efficient mechanism for the removal of waste toxins from the brain. Therefore, enhancing AQP4 function might protect against neurodegenerative diseases such as Alzheimer’s disease (AD), in which the accumulation of harmful proteins and solutes is a hallmark feature. Here, we test the effect of a putative AQP4 facilitator, TGN-073, on glymphatic transport in a normal rat brain by employing different MRI techniques. Surgical procedures were undertaken to catheterise the cisterna magna, thereby enabling infusion of the MRI tracer. Followed by the intraperitoneal injection of either TGN-073, or the vehicle. Using a paramagnetic contrast agent (Gd-DTPA) as the MRI tracer, dynamic 3D T1 weighted imaging of the glymphatic system was undertaken over two hours. Further, the apparent diffusion coefficient was measured in different brain regions using diffusion-weighted imaging (DWI). While physiological parameters and arterial blood gas analysis were monitored continuously. We found that rats treated with TGN-073 showed the distribution of Gd-DTPA was more extensive and parenchymal uptake was higher compared with the vehicle group. Water diffusivity was increased in the brain of TGN-073 treated group, which indicates greater water flux. Also, MRI showed the glymphatic transport and distribution in the brain is naturally heterogeneous, which is consistent with previous studies. Our results indicate that compounds such as TGN-073 can improve glymphatic function in the brain. Since glymphatic impairment due to AQP4 dysfunction is potentially associated with several neurological disorders such as AD, dementia and traumatic brain injury, enhancing AQP4 functionality might be a promising therapeutic target.
- 15 March 2023
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (3) , e0282955
Open AccessThe effect of a novel AQP4 facilitator, TGN-073, on glymphatic transport captured by diffusion MRI and DCE-MRI
The glymphatic system is a low resistance pathway, by which cerebrospinal fluid enters the brain parenchyma along perivascular spaces via AQP4 channels. It is hypothesised that the resulting convective flow of the interstitial fluid provides an efficient mechanism for the removal of waste toxins from the brain. Therefore, enhancing AQP4 function might protect against neurodegenerative diseases such as Alzheimer’s disease (AD), in which the accumulation of harmful proteins and solutes is a hallmark feature. Here, we test the effect of a putative AQP4 facilitator, TGN-073, on glymphatic transport in a normal rat brain by employing different MRI techniques. Surgical procedures were undertaken to catheterise the cisterna magna, thereby enabling infusion of the MRI tracer. Followed by the intraperitoneal injection of either TGN-073, or the vehicle. Using a paramagnetic contrast agent (Gd-DTPA) as the MRI tracer, dynamic 3D T1 weighted imaging of the glymphatic system was undertaken over two hours. Further, the apparent diffusion coefficient was measured in different brain regions using diffusion-weighted imaging (DWI). While physiological parameters and arterial blood gas analysis were monitored continuously. We found that rats treated with TGN-073 showed the distribution of Gd-DTPA was more extensive and parenchymal uptake was higher compared with the vehicle group. Water diffusivity was increased in the brain of TGN-073 treated group, which indicates greater water flux. Also, MRI showed the glymphatic transport and distribution in the brain is naturally heterogeneous, which is consistent with previous studies. Our results indicate that compounds such as TGN-073 can improve glymphatic function in the brain. Since glymphatic impairment due to AQP4 dysfunction is potentially associated with several neurological disorders such as AD, dementia and traumatic brain injury, enhancing AQP4 functionality might be a promising therapeutic target.
- 1 January 2022
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 85, 121-127
Evaluating potential of multi-parametric MRI using co-registered histology: Application to a mouse model of glioblastoma
- 1 January 2022
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 85, 121-127
Evaluating potential of multi-parametric MRI using co-registered histology: Application to a mouse model of glioblastoma
- Open Access
- 24 May 2021
- Published by American Society for Clinical Investigation in JCI Insight
- Vol. 6 (10)
Direct imaging of glymphatic transport using H217O MRI
The recently proposed glymphatic pathway for solute transport and waste clearance from the brain has been the focus of intense debate. By exploiting an isotopically enriched MRI tracer, H 2 17 O, we directly imaged glymphatic water transport in the rat brain in vivo. Our results reveal glymphatic transport that is dramatically faster and more extensive than previously thought and unlikely to be explained by diffusion alone. Moreover, we confirm the critical role of aquaporin-4 channels in glymphatic transport.
- 24 May 2021
- Published by American Society for Clinical Investigation in JCI Insight
- Vol. 6 (10)
Open AccessDirect imaging of glymphatic transport using H217O MRI
The recently proposed glymphatic pathway for solute transport and waste clearance from the brain has been the focus of intense debate. By exploiting an isotopically enriched MRI tracer, H 2 17 O, we directly imaged glymphatic water transport in the rat brain in vivo. Our results reveal glymphatic transport that is dramatically faster and more extensive than previously thought and unlikely to be explained by diffusion alone. Moreover, we confirm the critical role of aquaporin-4 channels in glymphatic transport.
- Open Access
- 20 April 2021
- Published by Springer Nature in Journal of Engineering Mathematics
- Vol. 128 (1) , 1-24
Modelling of fibre dispersion and its effects on cardiac mechanics from diastole to systole
Detailed fibre architecture plays a crucial role in myocardial mechanics both passively and actively. Strong interest has been attracted over decades in mathematical modelling of fibrous tissue (arterial wall, myocardium, etc.) by taking into account realistic fibre structures, i.e. from perfectly aligned one family of fibres, to two families of fibres, and to dispersed fibres described by probability distribution functions. It is widely accepted that the fibres, i.e. collage, cannot bear the load when compressed, thus it is necessary to exclude compressed fibres when computing the stress in fibrous tissue. In this study, we have focused on mathematical modelling of fibre dispersion in myocardial mechanics, and studied how different fibre dispersions affect cardiac pump function. The fibre dispersion in myocardium is characterized by a non-rotationally symmetric distribution using a $$\pi $$ -periodic Von Mises distribution based on recent experimental studies. In order to exclude compressed fibres for passive response, we adopted the discrete fibre dispersion model for approximating a continuous fibre distribution with finite fibre bundles, and then the general structural tensor was employed for describing dispersed active tension. We first studied the numerical accuracy of the integration of fibre contributions using the discrete fibre dispersion approach, then compared different mechanical responses in a uniaxially stretched myocardial sample with varied fibre dispersions. We finally studied the cardiac pump functions from diastole to systole in two heart models, a rabbit bi-ventricle model and a human left ventricle model. Our results show that the discrete fibre model is preferred for excluding compressed fibres because of its high computational efficiency. Both the diastolic filling and the systolic contraction will be affected by dispersed fibres depending on the in-plane and out-of-plane dispersion degrees, especially in systolic contraction. The in-plane dispersion seems affecting myocardial mechanics more than the out-of-plane dispersion. Despite different effects in the rabbit and human models caused by the fibre dispersion, large differences in pump function exist when fibres are highly dispersed at in-plane and out-of-plane. Our results highlight the necessity of using dispersed fibre models when modelling myocardial mechanics, especially when fibres are largely dispersed under pathological conditions, such as fibrosis.- 20 April 2021
- Published by Springer Nature in Journal of Engineering Mathematics
- Vol. 128 (1) , 1-24
Open AccessModelling of fibre dispersion and its effects on cardiac mechanics from diastole to systole
Detailed fibre architecture plays a crucial role in myocardial mechanics both passively and actively. Strong interest has been attracted over decades in mathematical modelling of fibrous tissue (arterial wall, myocardium, etc.) by taking into account realistic fibre structures, i.e. from perfectly aligned one family of fibres, to two families of fibres, and to dispersed fibres described by probability distribution functions. It is widely accepted that the fibres, i.e. collage, cannot bear the load when compressed, thus it is necessary to exclude compressed fibres when computing the stress in fibrous tissue. In this study, we have focused on mathematical modelling of fibre dispersion in myocardial mechanics, and studied how different fibre dispersions affect cardiac pump function. The fibre dispersion in myocardium is characterized by a non-rotationally symmetric distribution using a $$\pi $$ -periodic Von Mises distribution based on recent experimental studies. In order to exclude compressed fibres for passive response, we adopted the discrete fibre dispersion model for approximating a continuous fibre distribution with finite fibre bundles, and then the general structural tensor was employed for describing dispersed active tension. We first studied the numerical accuracy of the integration of fibre contributions using the discrete fibre dispersion approach, then compared different mechanical responses in a uniaxially stretched myocardial sample with varied fibre dispersions. We finally studied the cardiac pump functions from diastole to systole in two heart models, a rabbit bi-ventricle model and a human left ventricle model. Our results show that the discrete fibre model is preferred for excluding compressed fibres because of its high computational efficiency. Both the diastolic filling and the systolic contraction will be affected by dispersed fibres depending on the in-plane and out-of-plane dispersion degrees, especially in systolic contraction. The in-plane dispersion seems affecting myocardial mechanics more than the out-of-plane dispersion. Despite different effects in the rabbit and human models caused by the fibre dispersion, large differences in pump function exist when fibres are highly dispersed at in-plane and out-of-plane. Our results highlight the necessity of using dispersed fibre models when modelling myocardial mechanics, especially when fibres are largely dispersed under pathological conditions, such as fibrosis. - 1 April 2021
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 325, 106929
Impact of turbulence-induced asymmetric propagators on the accuracy of phase-contrast velocimetry
- 1 April 2021
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 325, 106929
Impact of turbulence-induced asymmetric propagators on the accuracy of phase-contrast velocimetry
- 1 October 2019
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 326, 108372
Stacked in-plane histology for quantitative validation of non-invasive imaging biomarkers: Application to an infiltrative brain tumour model
- 1 October 2019
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 326, 108372
Stacked in-plane histology for quantitative validation of non-invasive imaging biomarkers: Application to an infiltrative brain tumour model