Massimo Lodi
Research Subjects
Massimo Lodi has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Luciano Carbonari
Departmental Organizational Structure for Vascular Surgery and Centre of Vascular Access for the Marche Region, Ancona - Italy
2 shared publications- Luigi Tazza
Catholic University, 00168 Rome, Italy
2 shared publications - Andrea Remuzzi
University of Bergamo
1 shared publication - Carlo Lomonte
Nephrology Unit – F. Miulli General Hospital, Acquaviva delle Fonti, Italy
1 shared publication - Francesco Casucci
Unit of Nephrology and Dialysis, Ente Ecclesiastico "F. Miulli", Acquaviva delle Fonti, BA, Italy
1 shared publication Giuseppe Bonforte
E.O.C. Ospedale Beata Vergine, Mendrisio - Svizzera
1 shared publication
Latest Publications
- 1 March 2018
- Published by Aboutscience Srl in Giornale di Tecniche Nefrologiche e Dialitiche
- Vol. 30 (1) , 68-69
“Il Nefrologo forte”: la grande illusione?
- 1 March 2018
- Published by Aboutscience Srl in Giornale di Tecniche Nefrologiche e Dialitiche
- Vol. 30 (1) , 68-69
“Il Nefrologo forte”: la grande illusione?
- Open Access
- 14 March 2017
- Published by Springer Nature in BMC Medical Informatics and Decision Making
- Vol. 17 (1) , 26
Clinical use of computational modeling for surgical planning of arteriovenous fistula for hemodialysis
Autogenous arteriovenous fistula (AVF) is the best vascular access (VA) for hemodialysis, but its creation is still a critical procedure. Physical examination, vascular mapping and doppler ultrasound (DUS) evaluation are recommended for AVF planning, but they can not provide direct indication on AVF outcome. We recently developed and validated in a clinical trial a patient-specific computational model to predict pre-operatively the blood flow volume (BFV) in AVF for different surgical configuration on the basis of demographic, clinical and DUS data. In the present investigation we tested power of prediction and usability of the computational model in routine clinical setting. We developed a web-based system (AVF.SIM) that integrates the computational model in a single procedure, including data collection and transfer, simulation management and data storage. A usability test on observational data was designed to compare predicted vs. measured BFV and evaluate the acceptance of the system in the clinical setting. Six Italian nephrology units were involved in the evaluation for a 6-month period that included all incident dialysis patients with indication for AVF surgery. Out of the 74 patients, complete data from 60 patients were included in the final dataset. Predicted brachial BFV at 40 days after surgery showed a good correlation with measured values (in average 787 ± 306 vs. 751 ± 267 mL/min, R = 0.81, p < 0.001). For distal AVFs the mean difference (±SD) between predicted vs. measured BFV was −2.0 ± 20.9%, with 50% of predicted values in the range of 86–121% of measured BFV. Feedbacks provided by clinicians indicate that AVF.SIM is easy to use and well accepted in clinical routine, with limited additional workload. Clinical use of computational modeling for AVF surgical planning can help the surgeon to select the best surgical strategy, reducing AVF early failures and complications. This approach allows individualization of VA care, with the aim to reduce the costs associated with VA dysfunction, and to improve AVF clinical outcome.
- 14 March 2017
- Published by Springer Nature in BMC Medical Informatics and Decision Making
- Vol. 17 (1) , 26
Open AccessClinical use of computational modeling for surgical planning of arteriovenous fistula for hemodialysis
Autogenous arteriovenous fistula (AVF) is the best vascular access (VA) for hemodialysis, but its creation is still a critical procedure. Physical examination, vascular mapping and doppler ultrasound (DUS) evaluation are recommended for AVF planning, but they can not provide direct indication on AVF outcome. We recently developed and validated in a clinical trial a patient-specific computational model to predict pre-operatively the blood flow volume (BFV) in AVF for different surgical configuration on the basis of demographic, clinical and DUS data. In the present investigation we tested power of prediction and usability of the computational model in routine clinical setting. We developed a web-based system (AVF.SIM) that integrates the computational model in a single procedure, including data collection and transfer, simulation management and data storage. A usability test on observational data was designed to compare predicted vs. measured BFV and evaluate the acceptance of the system in the clinical setting. Six Italian nephrology units were involved in the evaluation for a 6-month period that included all incident dialysis patients with indication for AVF surgery. Out of the 74 patients, complete data from 60 patients were included in the final dataset. Predicted brachial BFV at 40 days after surgery showed a good correlation with measured values (in average 787 ± 306 vs. 751 ± 267 mL/min, R = 0.81, p < 0.001). For distal AVFs the mean difference (±SD) between predicted vs. measured BFV was −2.0 ± 20.9%, with 50% of predicted values in the range of 86–121% of measured BFV. Feedbacks provided by clinicians indicate that AVF.SIM is easy to use and well accepted in clinical routine, with limited additional workload. Clinical use of computational modeling for AVF surgical planning can help the surgeon to select the best surgical strategy, reducing AVF early failures and complications. This approach allows individualization of VA care, with the aim to reduce the costs associated with VA dysfunction, and to improve AVF clinical outcome.
- 27 September 2016
- Published by SAGE Publications in The Journal of Vascular Access
- Vol. 17 (6) , 548-551
The Removal of a Stuck Catheter: An Alternative to Hong's Technique
The use of the tunneled central venous catheter (CVC) is steadily increasing worldwide as a means of vascular access for hemodialysis. The increased use of these devices, which often outlive the patients, and the extended time they are used are associated with more frequent complications. Among these, one of the emerging complications is that of the “embedded” or stuck catheter. This term refers to when the catheter cannot be removed after detaching the retention cuff. In medical literature, experiences with the removal of stuck catheters are described with the use of several different methods. Currently the most commonly used technique also considered the safest is “endoluminal dilation” also known as Hong's Technique, recently modified by Quaretti and Galli. Below, a new technique using a Vollmar ring is described for removing a stuck catheter as an alternative to Hong's technique, or after a failed attempt at using Hong's technique.
- 27 September 2016
- Published by SAGE Publications in The Journal of Vascular Access
- Vol. 17 (6) , 548-551
The Removal of a Stuck Catheter: An Alternative to Hong's Technique
The use of the tunneled central venous catheter (CVC) is steadily increasing worldwide as a means of vascular access for hemodialysis. The increased use of these devices, which often outlive the patients, and the extended time they are used are associated with more frequent complications. Among these, one of the emerging complications is that of the “embedded” or stuck catheter. This term refers to when the catheter cannot be removed after detaching the retention cuff. In medical literature, experiences with the removal of stuck catheters are described with the use of several different methods. Currently the most commonly used technique also considered the safest is “endoluminal dilation” also known as Hong's Technique, recently modified by Quaretti and Galli. Below, a new technique using a Vollmar ring is described for removing a stuck catheter as an alternative to Hong's technique, or after a failed attempt at using Hong's technique.
- 26 January 2014
- Published by Aboutscience Srl in Giornale di Tecniche Nefrologiche e Dialitiche
- Vol. 26 (1) , 16-18
Buttonhole Technique: To Try or Not to Try?
- 26 January 2014
- Published by Aboutscience Srl in Giornale di Tecniche Nefrologiche e Dialitiche
- Vol. 26 (1) , 16-18
Buttonhole Technique: To Try or Not to Try?