Jiahang Shao
Research Subjects
Jiahang Shao has a total of 108 co-authors. Here are the top co-authors by number of shared publications:
Manoel Conde
High Energy Physics Division, Argonne National Laboratory 3 , Lemont, Illinois 60439, USA
6 shared publications- Sergey V. Baryshev
Department of Electrical and Computer Engineering Michigan State University 48824 MI USA
5 shared publications Wanming Liu
High Energy Physics Division, Argonne National Laboratory 3 , Lemont, Illinois 60439, USA
5 shared publicationsChunguang Jing
Euclid TechLabs LLC 2 , Bolingbrook, Illinois 60440, USA
4 shared publications- Eric E. Wisniewski
Argonne National Laboratory, Argonne, Illinois 60439, USA
4 shared publications - Gwanghui Ha
Argonne National Laboratory, Argonne, Illinois 60439, USA
4 shared publications
Latest Publications
- Open Access
- 16 November 2026
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 29 (11)
Harmonic modulation for ultrawide tuning range terahertz free-electron laser via frequency-beating laser modulation
Broadband tunability is a key pursuit for terahertz (THz) free-electron lasers, yet it is often constrained by the narrow energy acceptance of laser modulators in prebunched schemes. Here, we propose a harmonic modulation scheme to decouple this constraint. Taking the Electron Source Test Facility at Dalian as a specific case study, our simulations demonstrate that by matching the laser field to higher-order harmonic resonances of the undulator, we can obtain efficient energy modulation across a significantly wider electron energy range (40–130 MeV), surpassing the limit of 71–130 MeV imposed by the fundamental resonance. This technique facilitates continuous frequency tuning from 0.5 to 30 THz using a single modulator-radiator chain, establishing a versatile method for ultrabroadband THz generation.
- 16 November 2026
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 29 (11)
Open AccessHarmonic modulation for ultrawide tuning range terahertz free-electron laser via frequency-beating laser modulation
Broadband tunability is a key pursuit for terahertz (THz) free-electron lasers, yet it is often constrained by the narrow energy acceptance of laser modulators in prebunched schemes. Here, we propose a harmonic modulation scheme to decouple this constraint. Taking the Electron Source Test Facility at Dalian as a specific case study, our simulations demonstrate that by matching the laser field to higher-order harmonic resonances of the undulator, we can obtain efficient energy modulation across a significantly wider electron energy range (40–130 MeV), surpassing the limit of 71–130 MeV imposed by the fundamental resonance. This technique facilitates continuous frequency tuning from 0.5 to 30 THz using a single modulator-radiator chain, establishing a versatile method for ultrabroadband THz generation.
- Open Access
- 9 October 2025
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 28 (10)
Wavelength switching and scanning of the high-gain harmonic generation free-electron laser at the Dalian Coherent Light Source
The continuous wavelength tunability of free-electron lasers (FELs) offers significant potential for research across various scientific fields. The Dalian Coherent Light Source (DCLS), when operating in the high-gain harmonic generation (HGHG) mode, has demonstrated wavelength tuning capability within the vacuum ultraviolet (VUV) range of 50–150 nm. To address diverse experimental demands, it is imperative to have the capability of fast wavelength switching and scanning. This study presents three wavelength tuning strategies experimentally implemented at DCLS, each characterized by specific tuning ranges and resolutions: (i) full-range continuous wavelength switching over 50–150 nm, typically requiring more than 2 h; (ii) wide-range coarse wavelength scanning with approximately 20% variation within several minutes; and (iii) narrow-range fine wavelength scanning with a range of about 0.44% and a scanning resolution of 0.01% in less than 1 min. Each strategy has its own advantages and limitations, and their combination significantly enhances the flexibility of wavelength manipulation at DCLS, accommodating diverse user requirements.
- 9 October 2025
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 28 (10)
Open AccessWavelength switching and scanning of the high-gain harmonic generation free-electron laser at the Dalian Coherent Light Source
The continuous wavelength tunability of free-electron lasers (FELs) offers significant potential for research across various scientific fields. The Dalian Coherent Light Source (DCLS), when operating in the high-gain harmonic generation (HGHG) mode, has demonstrated wavelength tuning capability within the vacuum ultraviolet (VUV) range of 50–150 nm. To address diverse experimental demands, it is imperative to have the capability of fast wavelength switching and scanning. This study presents three wavelength tuning strategies experimentally implemented at DCLS, each characterized by specific tuning ranges and resolutions: (i) full-range continuous wavelength switching over 50–150 nm, typically requiring more than 2 h; (ii) wide-range coarse wavelength scanning with approximately 20% variation within several minutes; and (iii) narrow-range fine wavelength scanning with a range of about 0.44% and a scanning resolution of 0.01% in less than 1 min. Each strategy has its own advantages and limitations, and their combination significantly enhances the flexibility of wavelength manipulation at DCLS, accommodating diverse user requirements.
- 4 April 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1063
An experimental application of machine learning algorithms to optimize the FEL lasing via beam trajectory tuning at Dalian Coherent Light Source
- 4 April 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1063
An experimental application of machine learning algorithms to optimize the FEL lasing via beam trajectory tuning at Dalian Coherent Light Source
- Open Access
- 30 January 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 122 (5)
Effect of material composition of diamond field emission array cathodes on quality of transversely shaped beams
Diamond field emitter array field emission cathodes (DFEA FECs) are attractive for the next generation of injectors due to their ability to produce transversely shaped beams without the need for complex masking or laser schemes. However, reliability of this cathode technology remains a challenging issue as principal mechanisms guiding and allowing for output beam shaping remained poorly understood. This paper reports the results of testing two DFEA FECs with the same pattern and emitter tip geometry. Although both cathodes were able to sustain gradients of 44 MV/m and produce maximum output integral charge of 0.5 nC per radio frequency pulse, their emission patterns were different. One cathode did not produce a shaped beam, while the other one did. This difference was explained by the extent of the local variations of the diamond material across the arrays as discovered by spatially resolved Raman spectroscopy. The main practical takeaways were (i) tip sharpness was not a prerequisite for producing a shaped beam and instead (ii) material characteristics resulting in different cathode ballast resistance affected emission spatial uniformity across the array and hence the beam shaping.
- 30 January 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 122 (5)
Open AccessEffect of material composition of diamond field emission array cathodes on quality of transversely shaped beams
Diamond field emitter array field emission cathodes (DFEA FECs) are attractive for the next generation of injectors due to their ability to produce transversely shaped beams without the need for complex masking or laser schemes. However, reliability of this cathode technology remains a challenging issue as principal mechanisms guiding and allowing for output beam shaping remained poorly understood. This paper reports the results of testing two DFEA FECs with the same pattern and emitter tip geometry. Although both cathodes were able to sustain gradients of 44 MV/m and produce maximum output integral charge of 0.5 nC per radio frequency pulse, their emission patterns were different. One cathode did not produce a shaped beam, while the other one did. This difference was explained by the extent of the local variations of the diamond material across the arrays as discovered by spatially resolved Raman spectroscopy. The main practical takeaways were (i) tip sharpness was not a prerequisite for producing a shaped beam and instead (ii) material characteristics resulting in different cathode ballast resistance affected emission spatial uniformity across the array and hence the beam shaping.
- Open Access
- 17 December 2021
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 24 (12) , 123401
Ampere-class bright field emission cathode operated atHigh-current bright sources are needed to power the next generation of compact rf and microwave systems. A major requirement is that such sources could be sustainably operated at high frequencies, well above 1 GHz, and high gradients, well above . Field emission sources offer simplicity and scalability in a high-frequency era of the injector design, but the output rf cycle charge and high-gradient operation remain a great and largely unaddressed challenge. Here, a field emission cathode based on ultra-nano-crystalline diamond, an efficient planar field emission material, was tested at in an -band injector. A very high charge of 38 pC per rf cycle was demonstrated (300 nC per rf pulse corresponding to an rf pulse current of 120 mA). This operating condition revealed a two-dimensional space charge limited emission where the one-dimensional Child-Langmuir limit was surpassed. An injector brightness of was estimated for the given operating conditions.- 17 December 2021
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 24 (12) , 123401
Open AccessAmpere-class bright field emission cathode operated atHigh-current bright sources are needed to power the next generation of compact rf and microwave systems. A major requirement is that such sources could be sustainably operated at high frequencies, well above 1 GHz, and high gradients, well above . Field emission sources offer simplicity and scalability in a high-frequency era of the injector design, but the output rf cycle charge and high-gradient operation remain a great and largely unaddressed challenge. Here, a field emission cathode based on ultra-nano-crystalline diamond, an efficient planar field emission material, was tested at in an -band injector. A very high charge of 38 pC per rf cycle was demonstrated (300 nC per rf pulse corresponding to an rf pulse current of 120 mA). This operating condition revealed a two-dimensional space charge limited emission where the one-dimensional Child-Langmuir limit was surpassed. An injector brightness of was estimated for the given operating conditions. - 1 May 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (5) , 053305
FEbeam: Cavity and electron emission data conversion, processing, and analysis. A freeware toolkit for rf injectors
FEbeam is an all-in-one field emission data processing interface with the capability to analyze the field emission cathode performance in an rf injector by extracting the field enhancement factor, local field, and effective emission area from the Fowler–Nordheim equations. It also has the capability of processing beam imaging micrographs using its sister software, FEpic. The current version of FEbeam was designed for the Argonne Cathode Test-stand of the Argonne Wakefield Accelerator facility switch yard. With slight modifications, FEbeam could work for many rf field emission injectors. This software is open-source and can be found at GitHub.
- 1 May 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (5) , 053305
FEbeam: Cavity and electron emission data conversion, processing, and analysis. A freeware toolkit for rf injectors
FEbeam is an all-in-one field emission data processing interface with the capability to analyze the field emission cathode performance in an rf injector by extracting the field enhancement factor, local field, and effective emission area from the Fowler–Nordheim equations. It also has the capability of processing beam imaging micrographs using its sister software, FEpic. The current version of FEbeam was designed for the Argonne Cathode Test-stand of the Argonne Wakefield Accelerator facility switch yard. With slight modifications, FEbeam could work for many rf field emission injectors. This software is open-source and can be found at GitHub.
- 26 October 2020
- Published by AIP Publishing in Applied Physics Letters
- Vol. 117 (17) , 171903
Demonstration of nitrogen-incorporated ultrananocrystalline diamond photocathodes in a RF gun environment
Quantum efficiency (QE), intrinsic emittance, and robustness are the three most important figures of merit for photocathodes, the first two determine the ultimate achievable brightness of an electron beam, and the third one directly correlates with the complications of a beamline design. Nitrogen-incorporated ultrananocrystalline diamond [(N)UNCD] materials are promising candidates for photocathode applications due to their remarkable electron emission performance as well as the moderate vacuum requirement. Two (N)UNCD photocathodes have been characterized in a realistic RF gun environment with the nicely balanced performance of all three figures of merit. The QE of the first (N)UNCD cathode (stored in air for two years before the test) was found to be 3.8 × 10−4 using a 262 nm UV laser and a cathode surface field of 30 MV/m. It was found that the QE of the second (N)UNCD sample (grown days before the test) was nearly the same and, therefore, demonstrates the exceptional environmental tolerance of the material. The intrinsic emittance of (N)UNCD was measured to be 1.00 μm/mm.
- 26 October 2020
- Published by AIP Publishing in Applied Physics Letters
- Vol. 117 (17) , 171903
Demonstration of nitrogen-incorporated ultrananocrystalline diamond photocathodes in a RF gun environment
Quantum efficiency (QE), intrinsic emittance, and robustness are the three most important figures of merit for photocathodes, the first two determine the ultimate achievable brightness of an electron beam, and the third one directly correlates with the complications of a beamline design. Nitrogen-incorporated ultrananocrystalline diamond [(N)UNCD] materials are promising candidates for photocathode applications due to their remarkable electron emission performance as well as the moderate vacuum requirement. Two (N)UNCD photocathodes have been characterized in a realistic RF gun environment with the nicely balanced performance of all three figures of merit. The QE of the first (N)UNCD cathode (stored in air for two years before the test) was found to be 3.8 × 10−4 using a 262 nm UV laser and a cathode surface field of 30 MV/m. It was found that the QE of the second (N)UNCD sample (grown days before the test) was nearly the same and, therefore, demonstrates the exceptional environmental tolerance of the material. The intrinsic emittance of (N)UNCD was measured to be 1.00 μm/mm.
- 29 June 2020
- Published by AIP Publishing in Applied Physics Letters
- Vol. 116 (26) , 264102
Coherent high-power RF wakefield generation by electron bunch trains in a metamaterial structure
We present an experimental study of coherent high-power wakefield generation in a metamaterial (MTM) structure at 11.7 GHz by 65 MeV electron bunch trains at the Argonne Wakefield Accelerator (AWA), following a previous experiment, the Stage-I experiment, at the AWA. Both the Stage-II experiment, reported in this paper, and the Stage-I experiment were conducted using MTM structures, which are all-metal periodic structures with the period being much smaller than the wavelength. Differences between the two experiments include (1) structure length (Stage-I 8 cm and Stage-II 20 cm); (2) number of bunches used to excite the structure (Stage-I with two bunches, up to 85 nC of total charge; Stage-II with eight bunches, up to 224 nC of total charge); and (3) highest peak power measured (Stage-I 80 MW in a 2 ns pulse and Stage-II 380 MW in a 10 ns pulse). High-power radio frequency pulses were generated by reversed Cherenkov radiation of the electron beam due to the negative group velocity in the MTM structures. Because the radiation is coherent, a train of bunches with a proper spacing can build up to achieve a high peak power. The observed output power levels are very promising for future applications in direct collinear wakefield acceleration or in transfer to a second accelerator for two-beam acceleration.
- 29 June 2020
- Published by AIP Publishing in Applied Physics Letters
- Vol. 116 (26) , 264102
Coherent high-power RF wakefield generation by electron bunch trains in a metamaterial structure
We present an experimental study of coherent high-power wakefield generation in a metamaterial (MTM) structure at 11.7 GHz by 65 MeV electron bunch trains at the Argonne Wakefield Accelerator (AWA), following a previous experiment, the Stage-I experiment, at the AWA. Both the Stage-II experiment, reported in this paper, and the Stage-I experiment were conducted using MTM structures, which are all-metal periodic structures with the period being much smaller than the wavelength. Differences between the two experiments include (1) structure length (Stage-I 8 cm and Stage-II 20 cm); (2) number of bunches used to excite the structure (Stage-I with two bunches, up to 85 nC of total charge; Stage-II with eight bunches, up to 224 nC of total charge); and (3) highest peak power measured (Stage-I 80 MW in a 2 ns pulse and Stage-II 380 MW in a 10 ns pulse). High-power radio frequency pulses were generated by reversed Cherenkov radiation of the electron beam due to the negative group velocity in the MTM structures. Because the radiation is coherent, a train of bunches with a proper spacing can build up to achieve a high peak power. The observed output power levels are very promising for future applications in direct collinear wakefield acceleration or in transfer to a second accelerator for two-beam acceleration.
- Open Access
- 4 May 2020
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 23 (5) , 052801
Rapid thermal emittance and quantum efficiency mapping of a cesium telluride cathode in an rf photoinjector using multiple laser beamlets
Thermal emittance and quantum efficiency (QE) are key figures of merit of photocathodes, and their uniformity is critical to high-performance photoinjectors. Several QE mapping technologies have been successfully developed; however, there is still a dearth of information on thermal emittance maps. This is because of the extremely time-consuming procedure to gather measurements by scanning a small beam across the cathode with fine steps. To simplify the mapping procedure and to reduce the time required to take measurements, we propose a new method that requires only a single scan of the solenoid current to simultaneously obtain thermal emittance and QE distribution by using a pattern beam with multiple beamlets. In this paper, its feasibility has been confirmed by both beam dynamics simulation and theoretical analysis. The method has been successfully demonstrated in a proof-of-principle experiment using an L-band radio-frequency photoinjector with a cesium telluride cathode. In the experiment, seven beamlets were generated from a microlens array system and their corresponding thermal emittance and QE varied from 0.93 to and from 4.6% to 8.7%, respectively. We also discuss the limitations and future improvements of the method in this paper.- 4 May 2020
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 23 (5) , 052801
Open AccessRapid thermal emittance and quantum efficiency mapping of a cesium telluride cathode in an rf photoinjector using multiple laser beamlets
Thermal emittance and quantum efficiency (QE) are key figures of merit of photocathodes, and their uniformity is critical to high-performance photoinjectors. Several QE mapping technologies have been successfully developed; however, there is still a dearth of information on thermal emittance maps. This is because of the extremely time-consuming procedure to gather measurements by scanning a small beam across the cathode with fine steps. To simplify the mapping procedure and to reduce the time required to take measurements, we propose a new method that requires only a single scan of the solenoid current to simultaneously obtain thermal emittance and QE distribution by using a pattern beam with multiple beamlets. In this paper, its feasibility has been confirmed by both beam dynamics simulation and theoretical analysis. The method has been successfully demonstrated in a proof-of-principle experiment using an L-band radio-frequency photoinjector with a cesium telluride cathode. In the experiment, seven beamlets were generated from a microlens array system and their corresponding thermal emittance and QE varied from 0.93 to and from 4.6% to 8.7%, respectively. We also discuss the limitations and future improvements of the method in this paper. - Open Access
- 3 January 2020
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 23 (1) , 011301
Development and high-power testing of an -band dielectric-loaded power extractorDielectric-loaded structures are promising candidates for use in structure wakefield acceleration. They could be useful for both the collinear wakefield and the two-beam acceleration (TBA) approaches, due to their low fabrication cost, low radio-frequency (rf) losses, and potential to withstand high gradients. A short rf pulse () TBA program is currently being developed at the Argonne Wakefield Accelerator (AWA) facility, where dielectric-loaded structures are being used for both the power extraction and transfer structure (PETS) and the accelerator. In this study, an -band 11.7 GHz dielectric PETS was developed and tested at AWA to demonstrate high-power, short-pulse wakefield generation. The PETS was driven by a 1.3 GHz train of eight electron bunches separated by 769.2 ps (9 times the -band rf period) in order to achieve coherent wakefield superposition. A total train charge of 360 nC was passed through the PETS structure to generate , flat-top rf pulses without rf breakdown. A future experiment is being planned to increase the generated rf power to approximately by optimizing the structure design and improving the drive beam quality.- 3 January 2020
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 23 (1) , 011301
Open AccessDevelopment and high-power testing of an -band dielectric-loaded power extractorDielectric-loaded structures are promising candidates for use in structure wakefield acceleration. They could be useful for both the collinear wakefield and the two-beam acceleration (TBA) approaches, due to their low fabrication cost, low radio-frequency (rf) losses, and potential to withstand high gradients. A short rf pulse () TBA program is currently being developed at the Argonne Wakefield Accelerator (AWA) facility, where dielectric-loaded structures are being used for both the power extraction and transfer structure (PETS) and the accelerator. In this study, an -band 11.7 GHz dielectric PETS was developed and tested at AWA to demonstrate high-power, short-pulse wakefield generation. The PETS was driven by a 1.3 GHz train of eight electron bunches separated by 769.2 ps (9 times the -band rf period) in order to achieve coherent wakefield superposition. A total train charge of 360 nC was passed through the PETS structure to generate , flat-top rf pulses without rf breakdown. A future experiment is being planned to increase the generated rf power to approximately by optimizing the structure design and improving the drive beam quality.