Svenja Ipsen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Svenja Ipsen has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Achim Schweikard
University of Luebeck
4 shared publications- Floris Ernst
Universität zu Lübeck, Institut für Robotik und Kognitive Systeme, Ratzeburger Allee 160, Hs. 64, 23562 Lübeck , Germany
3 shared publications - Oliver Blanck
Department of Radiation Oncology, University Medical Center Schleswig-Holstein, Kiel, Germany
3 shared publications - Paul Keall
The University of Sydney
3 shared publications Ralf Bruder
Institute for Robotics and Cognitive Systems, Universität zu Lübeck, Lübeck , Germany
3 shared publications- Achim Schweikard
University of Lübeck
2 shared publications
Latest Publications
- Open Access
- 23 April 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (9) , 094002
Towards automated ultrasound imaging—robotic image acquisition in liver and prostate for long-term motion monitoring
Real-time volumetric (4D) ultrasound has shown high potential for diagnostic and therapy guidance tasks. One of the main drawbacks of ultrasound imaging to date is the reliance on manual probe positioning and the resulting user dependence. Robotic assistance could help overcome this issue and facilitate the acquisition of long-term image data to observe dynamic processes in vivo over time. The aim of this study is to assess the feasibility of robotic probe manipulation and organ motion quantification during extended imaging sessions. The system consists of a collaborative robot and a 4D ultrasound system providing real-time data access. Five healthy volunteers received liver and prostate scans during free breathing over 30 min. Initial probe placement was performed with real-time remote control with a predefined contact force of 10 N. During scan acquisition, the probe position was continuously adjusted to the body surface motion using impedance control. Ultrasound volumes, the pose of the end-effector and the estimated contact forces were recorded. For motion analysis, one anatomical landmark was manually annotated in a subset of ultrasound frames for each experiment. Probe contact was uninterrupted over the entire scan duration in all ten sessions. Organ drift and imaging artefacts were successfully compensated using remote control. The median contact force along the probe’s longitudinal axis was 10.0 N with maximum values of 13.2 and 21.3 N for liver and prostate, respectively. Forces exceeding 11 N only occurred in 0.3% of the time. Probe and landmark motion were more pronounced in the liver, with median interquartile ranges of 1.5 and 9.6 mm, compared to 0.6 and 2.7 mm in the prostate. The results show that robotic ultrasound imaging with dynamic force control can be used for stable, long-term imaging of anatomical regions affected by motion. The system facilitates the acquisition of 4D image data in vivo over extended scanning periods for the first time and holds the potential to be used for motion monitoring for therapy guidance as well as diagnostic tasks.
- 23 April 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (9) , 094002
Open AccessTowards automated ultrasound imaging—robotic image acquisition in liver and prostate for long-term motion monitoring
Real-time volumetric (4D) ultrasound has shown high potential for diagnostic and therapy guidance tasks. One of the main drawbacks of ultrasound imaging to date is the reliance on manual probe positioning and the resulting user dependence. Robotic assistance could help overcome this issue and facilitate the acquisition of long-term image data to observe dynamic processes in vivo over time. The aim of this study is to assess the feasibility of robotic probe manipulation and organ motion quantification during extended imaging sessions. The system consists of a collaborative robot and a 4D ultrasound system providing real-time data access. Five healthy volunteers received liver and prostate scans during free breathing over 30 min. Initial probe placement was performed with real-time remote control with a predefined contact force of 10 N. During scan acquisition, the probe position was continuously adjusted to the body surface motion using impedance control. Ultrasound volumes, the pose of the end-effector and the estimated contact forces were recorded. For motion analysis, one anatomical landmark was manually annotated in a subset of ultrasound frames for each experiment. Probe contact was uninterrupted over the entire scan duration in all ten sessions. Organ drift and imaging artefacts were successfully compensated using remote control. The median contact force along the probe’s longitudinal axis was 10.0 N with maximum values of 13.2 and 21.3 N for liver and prostate, respectively. Forces exceeding 11 N only occurred in 0.3% of the time. Probe and landmark motion were more pronounced in the liver, with median interquartile ranges of 1.5 and 9.6 mm, compared to 0.6 and 2.7 mm in the prostate. The results show that robotic ultrasound imaging with dynamic force control can be used for stable, long-term imaging of anatomical regions affected by motion. The system facilitates the acquisition of 4D image data in vivo over extended scanning periods for the first time and holds the potential to be used for motion monitoring for therapy guidance as well as diagnostic tasks.
- Top Cited PapersOpen Access
- 22 February 2021
- Published by Springer Nature in Current Robotics Reports
- Vol. 2 (1) , 55-71
Medical Robotics for Ultrasound Imaging: Current Systems and Future Trends
Purpose of Review: This review provides an overview of the most recent robotic ultrasound systems that have contemporary emerged over the past five years, highlighting their status and future directions. The systems are categorized based on their level of robot autonomy (LORA). Recent Findings: Teleoperating systems show the highest level of technical maturity. Collaborative assisting and autonomous systems are still in the research phase, with a focus on ultrasound image processing and force adaptation strategies. However, missing key factors are clinical studies and appropriate safety strategies. Future research will likely focus on artificial intelligence and virtual/augmented reality to improve image understanding and ergonomics. Summary: A review on robotic ultrasound systems is presented in which first technical specifications are outlined. Hereafter, the literature of the past five years is subdivided into teleoperation, collaborative assistance, or autonomous systems based on LORA. Finally, future trends for robotic ultrasound systems are reviewed with a focus on artificial intelligence and virtual/augmented reality.
- 22 February 2021
- Published by Springer Nature in Current Robotics Reports
- Vol. 2 (1) , 55-71
Top Cited PapersOpen AccessMedical Robotics for Ultrasound Imaging: Current Systems and Future Trends
Purpose of Review: This review provides an overview of the most recent robotic ultrasound systems that have contemporary emerged over the past five years, highlighting their status and future directions. The systems are categorized based on their level of robot autonomy (LORA). Recent Findings: Teleoperating systems show the highest level of technical maturity. Collaborative assisting and autonomous systems are still in the research phase, with a focus on ultrasound image processing and force adaptation strategies. However, missing key factors are clinical studies and appropriate safety strategies. Future research will likely focus on artificial intelligence and virtual/augmented reality to improve image understanding and ergonomics. Summary: A review on robotic ultrasound systems is presented in which first technical specifications are outlined. Hereafter, the literature of the past five years is subdivided into teleoperation, collaborative assistance, or autonomous systems based on LORA. Finally, future trends for robotic ultrasound systems are reviewed with a focus on artificial intelligence and virtual/augmented reality.
- Open Access
- 1 September 2019
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 5 (1) , 245-248
Assessment of 4D Ultrasound Systems for Image-guided Radiation Therapy – Image Quality, Framerates and CT Artifacts
4D ultrasound (4D US) is gaining relevance as a tracking method in radiation therapy (RT) with modern matrix array probes offering new possibilities for real-time target detection. However, for clinical implementation of USguided RT, image quality, volumetric framerate and artifacts caused by the probe’s presence during planning and / or setup computed tomography (CT) must be quantified. We compared three diagnostic 4D US systems with matrix array probes using a commercial wire phantom to measure spatial resolution as well as a calibration and a torso phantom to assess different image quality metrics. CT artifacts were quantified in the torso phantom by calculating the total variation and percentage of affected voxels between a reference CT scan and CT scans with probes in place. We found that state-of-the-art 4D US systems with small probes can fit inside the CT bore and cause fewer metal artifacts than larger probes. US image quality varies between systems and is task-dependent. Volume sizes and framerates are much higher than the commercial guidance solution for US-guided RT, warranting further investigation regarding clinical performance for image guidance.
- 1 September 2019
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 5 (1) , 245-248
Open AccessAssessment of 4D Ultrasound Systems for Image-guided Radiation Therapy – Image Quality, Framerates and CT Artifacts
4D ultrasound (4D US) is gaining relevance as a tracking method in radiation therapy (RT) with modern matrix array probes offering new possibilities for real-time target detection. However, for clinical implementation of USguided RT, image quality, volumetric framerate and artifacts caused by the probe’s presence during planning and / or setup computed tomography (CT) must be quantified. We compared three diagnostic 4D US systems with matrix array probes using a commercial wire phantom to measure spatial resolution as well as a calibration and a torso phantom to assess different image quality metrics. CT artifacts were quantified in the torso phantom by calculating the total variation and percentage of affected voxels between a reference CT scan and CT scans with probes in place. We found that state-of-the-art 4D US systems with small probes can fit inside the CT bore and cause fewer metal artifacts than larger probes. US image quality varies between systems and is task-dependent. Volume sizes and framerates are much higher than the commercial guidance solution for US-guided RT, warranting further investigation regarding clinical performance for image guidance.
- 1 January 2018
- Published by Elsevier in Physica Medica
- Vol. 45, 44-51
Investigation of the XCAT phantom as a validation tool in cardiac MRI tracking algorithms
- 1 January 2018
- Published by Elsevier in Physica Medica
- Vol. 45, 44-51
Investigation of the XCAT phantom as a validation tool in cardiac MRI tracking algorithms
- Open Access
- 8 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 559-561
Robotic 4D ultrasound solution for real-time visualization and teleoperation
Automation of the image acquisition process via robotic solutions offer a large leap towards resolving ultrasound’s user-dependency. This paper, as part of a larger project aimed to develop a multipurpose 4d-ultrasonic force-sensitive robot for medical applications, focuses on achieving real-time remote visualisation for 4d ultrasound image transfer. This was possible through implementing our software modification on a GE Vivid 7 Dimension workstation, which operates a matrix array probe controlled by a KUKA LBR iiwa 7 7-DOF robotic arm. With the help of robotic positioning and the matrix array probe, fast volumetric imaging of target regions was feasible. By testing ultrasound volumes, which were roughly 880 kB in size, while using gigabit Ethernet connection, a latency of ∼57 ms was achievable for volume transfer between the ultrasound station and a remote client application, which as a result allows a frame count of 17.4 fps. Our modification thus offers for the first time real-time remote visualization, recording and control of 4d ultrasound data, which can be implemented in teleoperation.
- 8 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 559-561
Open AccessRobotic 4D ultrasound solution for real-time visualization and teleoperation
Automation of the image acquisition process via robotic solutions offer a large leap towards resolving ultrasound’s user-dependency. This paper, as part of a larger project aimed to develop a multipurpose 4d-ultrasonic force-sensitive robot for medical applications, focuses on achieving real-time remote visualisation for 4d ultrasound image transfer. This was possible through implementing our software modification on a GE Vivid 7 Dimension workstation, which operates a matrix array probe controlled by a KUKA LBR iiwa 7 7-DOF robotic arm. With the help of robotic positioning and the matrix array probe, fast volumetric imaging of target regions was feasible. By testing ultrasound volumes, which were roughly 880 kB in size, while using gigabit Ethernet connection, a latency of ∼57 ms was achievable for volume transfer between the ultrasound station and a remote client application, which as a result allows a frame count of 17.4 fps. Our modification thus offers for the first time real-time remote visualization, recording and control of 4d ultrasound data, which can be implemented in teleoperation.
- Open Access
- 1 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 75-78
Simultaneous acquisition of 4D ultrasound and wireless electromagnetic tracking for in-vivo accuracy validation
Ultrasound is being increasingly investigated for real-time target localization in image-guided interventions. Yet, in-vivo validation remains challenging due to the difficulty to obtain a reliable ground truth. For this purpose, real-time volumetric (4D) ultrasound imaging was performed simultaneously with electromagnetic localization of three wireless transponders implanted in the liver of a radiotherapy patient. 4D ultrasound and electromagnetic tracking were acquired at framerates of 12Hz and 8Hz, respectively, during free breathing over 8 min following treatment. The electromagnetic antenna was placed directly above and the ultrasound probe on the right side of the patient to visualize the liver transponders. It was possible to record 25.7 s of overlapping ultrasound and electromagnetic position data of one transponder. Good spatial alignment with 0.6 mm 3D root-mean-square error between both traces was achieved using a rigid landmark transform. However, data acquisition was impaired since the electromagnetic tracking highly influenced the ultrasound equipment and vice versa. High intensity noise streaks appeared in the ultrasound scan lines irrespective of the chosen frequency (1.7-3.3 MHz, 2/4 MHz harmonic). To allow for target visualization and tracking in the ultrasound volumes despite the artefacts, an online filter was designed where corrupted pixels in the newest ultrasound frame were replaced with non-corrupted pixels from preceding frames. Aside from these artefacts, the recorded electromagnetic tracking data was fragmented and only the transponder closest to the antenna could be detected over a limited period of six consecutive breathing cycles. This problem was most likely caused by interference from the metal holder of the ultrasound probe and was solved in a subsequent experiment using a 3D-printed non-metal probe fixation. Real-time wireless electromagnetic tracking was compared with 4D ultrasound imaging in-vivo for the first time. For stable tracking, large metal components need to be avoided during data acquisition and ultrasound filtering is required.
- 1 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 75-78
Open AccessSimultaneous acquisition of 4D ultrasound and wireless electromagnetic tracking for in-vivo accuracy validation
Ultrasound is being increasingly investigated for real-time target localization in image-guided interventions. Yet, in-vivo validation remains challenging due to the difficulty to obtain a reliable ground truth. For this purpose, real-time volumetric (4D) ultrasound imaging was performed simultaneously with electromagnetic localization of three wireless transponders implanted in the liver of a radiotherapy patient. 4D ultrasound and electromagnetic tracking were acquired at framerates of 12Hz and 8Hz, respectively, during free breathing over 8 min following treatment. The electromagnetic antenna was placed directly above and the ultrasound probe on the right side of the patient to visualize the liver transponders. It was possible to record 25.7 s of overlapping ultrasound and electromagnetic position data of one transponder. Good spatial alignment with 0.6 mm 3D root-mean-square error between both traces was achieved using a rigid landmark transform. However, data acquisition was impaired since the electromagnetic tracking highly influenced the ultrasound equipment and vice versa. High intensity noise streaks appeared in the ultrasound scan lines irrespective of the chosen frequency (1.7-3.3 MHz, 2/4 MHz harmonic). To allow for target visualization and tracking in the ultrasound volumes despite the artefacts, an online filter was designed where corrupted pixels in the newest ultrasound frame were replaced with non-corrupted pixels from preceding frames. Aside from these artefacts, the recorded electromagnetic tracking data was fragmented and only the transponder closest to the antenna could be detected over a limited period of six consecutive breathing cycles. This problem was most likely caused by interference from the metal holder of the ultrasound probe and was solved in a subsequent experiment using a 3D-printed non-metal probe fixation. Real-time wireless electromagnetic tracking was compared with 4D ultrasound imaging in-vivo for the first time. For stable tracking, large metal components need to be avoided during data acquisition and ultrasound filtering is required.
- 1 January 2017
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 62 (s1) , s103-s108
Poster session 4. Image guided, robotic and miniaturised systems for intervention and therapy I
- 1 January 2017
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 62 (s1) , s103-s108
Poster session 4. Image guided, robotic and miniaturised systems for intervention and therapy I
- 25 October 2016
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 61 (22) , 7848-7863
Towards real-time MRI-guided 3D localization of deforming targets for non-invasive cardiac radiosurgery
Radiosurgery to the pulmonary vein antrum in the left atrium (LA) has recently been proposed for non-invasive treatment of atrial fibrillation (AF). Precise real-time target localization during treatment is necessary due to complex respiratory and cardiac motion and high radiation doses. To determine the 3D position of the LA for motion compensation during radiosurgery, a tracking method based on orthogonal real-time MRI planes was developed for AF treatments with an MRI-guided radiotherapy system. Four healthy volunteers underwent cardiac MRI of the LA. Contractile motion was quantified on 3D LA models derived from 4D scans with 10 phases acquired in end-exhalation. Three localization strategies were developed and tested retrospectively on 2D real-time scans (sagittal, temporal resolution 100 ms, free breathing). The best-performing method was then used to measure 3D target positions in 2D–2D orthogonal planes (sagittal-coronal, temporal resolution 200–252 ms, free breathing) in 20 configurations of a digital phantom and in the volunteer data. The 3D target localization accuracy was quantified in the phantom and qualitatively assessed in the real data. Mean cardiac contraction was ⩽ 3.9 mm between maximum dilation and contraction but anisotropic. A template matching approach with two distinct template phases and ECG-based selection yielded the highest 2D accuracy of 1.2 mm. 3D target localization showed a mean error of 3.2 mm in the customized digital phantoms. Our algorithms were successfully applied to the 2D–2D volunteer data in which we measured a mean 3D LA motion extent of 16.5 mm (SI), 5.8 mm (AP) and 3.1 mm (LR). Real-time target localization on orthogonal MRI planes was successfully implemented for highly deformable targets treated in cardiac radiosurgery. The developed method measures target shifts caused by respiration and cardiac contraction. If the detected motion can be compensated accordingly, an MRI-guided radiotherapy system could potentially enable completely non-invasive treatment of AF.
- 25 October 2016
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 61 (22) , 7848-7863
Towards real-time MRI-guided 3D localization of deforming targets for non-invasive cardiac radiosurgery
Radiosurgery to the pulmonary vein antrum in the left atrium (LA) has recently been proposed for non-invasive treatment of atrial fibrillation (AF). Precise real-time target localization during treatment is necessary due to complex respiratory and cardiac motion and high radiation doses. To determine the 3D position of the LA for motion compensation during radiosurgery, a tracking method based on orthogonal real-time MRI planes was developed for AF treatments with an MRI-guided radiotherapy system. Four healthy volunteers underwent cardiac MRI of the LA. Contractile motion was quantified on 3D LA models derived from 4D scans with 10 phases acquired in end-exhalation. Three localization strategies were developed and tested retrospectively on 2D real-time scans (sagittal, temporal resolution 100 ms, free breathing). The best-performing method was then used to measure 3D target positions in 2D–2D orthogonal planes (sagittal-coronal, temporal resolution 200–252 ms, free breathing) in 20 configurations of a digital phantom and in the volunteer data. The 3D target localization accuracy was quantified in the phantom and qualitatively assessed in the real data. Mean cardiac contraction was ⩽ 3.9 mm between maximum dilation and contraction but anisotropic. A template matching approach with two distinct template phases and ECG-based selection yielded the highest 2D accuracy of 1.2 mm. 3D target localization showed a mean error of 3.2 mm in the customized digital phantoms. Our algorithms were successfully applied to the 2D–2D volunteer data in which we measured a mean 3D LA motion extent of 16.5 mm (SI), 5.8 mm (AP) and 3.1 mm (LR). Real-time target localization on orthogonal MRI planes was successfully implemented for highly deformable targets treated in cardiac radiosurgery. The developed method measures target shifts caused by respiration and cardiac contraction. If the detected motion can be compensated accordingly, an MRI-guided radiotherapy system could potentially enable completely non-invasive treatment of AF.
- 28 September 2016
- Published by Wiley in Medical Physics
- Vol. 43 (10) , 5695-5704
Online 4D ultrasound guidance for real‐time motion compensation by MLC tracking
Purpose: With the trend in radiotherapy moving toward dose escalation and hypofractionation, the need for highly accurate targeting increases. While MLC tracking is already being successfully used for motion compensation of moving targets in the prostate, current real‐time target localization methods rely on repeated x‐ray imaging and implanted fiducial markers or electromagnetic transponders rather than direct target visualization. In contrast, ultrasound imaging can yield volumetric data in real‐time (3D + time = 4D) without ionizing radiation. The authors report the first results of combining these promising techniques—online 4D ultrasound guidance and MLC tracking—in a phantom.Methods: A software framework for real‐time target localization was installed directly on a 4D ultrasound station and used to detect a 2 mm spherical lead marker inside a water tank. The lead marker was rigidly attached to a motion stage programmed to reproduce nine characteristic tumor trajectories chosen from large databases (five prostate, four lung). The 3D marker position detected by ultrasound was transferred to a computer program for MLC tracking at a rate of 21.3 Hz and used for real‐time MLC aperture adaption on a conventional linear accelerator. The tracking system latency was measured using sinusoidal trajectories and compensated for by applying a kernel density prediction algorithm for the lung traces. To measure geometric accuracy, static anterior and lateral conformal fields as well as a 358° arc with a 10 cm circular aperture were delivered for each trajectory. The two‐dimensional (2D) geometric tracking error was measured as the difference between marker position and MLC aperture center in continuously acquired portal images. For dosimetric evaluation, VMAT treatment plans with high and low modulation were delivered to a biplanar diode array dosimeter using the same trajectories. Dose measurements with and without MLC tracking were compared to a static reference dose using 3%/3 mm and 2%/2 mm γ‐tests.Results: The overall tracking system latency was 172 ms. The mean 2D root‐mean‐square tracking error was 1.03 mm (0.80 mm prostate, 1.31 mm lung). MLC tracking improved the dose delivery in all cases with an overall reduction in the γ‐failure rate of 91.2% (3%/3 mm) and 89.9% (2%/2 mm) compared to no motion compensation. Low modulation VMAT plans had no (3%/3 mm) or minimal (2%/2 mm) residual γ‐failures while tracking reduced the γ‐failure rate from 17.4% to 2.8% (3%/3 mm) and from 33.9% to 6.5% (2%/2 mm) for plans with high modulation.Conclusions: Real‐time 4D ultrasound tracking was successfully integrated with online MLC tracking for the first time. The developed framework showed an accuracy and latency comparable with other MLC tracking methods while holding the potential to measure and adapt to target motion, including rotation and deformation, noninvasively.
- 28 September 2016
- Published by Wiley in Medical Physics
- Vol. 43 (10) , 5695-5704
Online 4D ultrasound guidance for real‐time motion compensation by MLC tracking
Purpose: With the trend in radiotherapy moving toward dose escalation and hypofractionation, the need for highly accurate targeting increases. While MLC tracking is already being successfully used for motion compensation of moving targets in the prostate, current real‐time target localization methods rely on repeated x‐ray imaging and implanted fiducial markers or electromagnetic transponders rather than direct target visualization. In contrast, ultrasound imaging can yield volumetric data in real‐time (3D + time = 4D) without ionizing radiation. The authors report the first results of combining these promising techniques—online 4D ultrasound guidance and MLC tracking—in a phantom.Methods: A software framework for real‐time target localization was installed directly on a 4D ultrasound station and used to detect a 2 mm spherical lead marker inside a water tank. The lead marker was rigidly attached to a motion stage programmed to reproduce nine characteristic tumor trajectories chosen from large databases (five prostate, four lung). The 3D marker position detected by ultrasound was transferred to a computer program for MLC tracking at a rate of 21.3 Hz and used for real‐time MLC aperture adaption on a conventional linear accelerator. The tracking system latency was measured using sinusoidal trajectories and compensated for by applying a kernel density prediction algorithm for the lung traces. To measure geometric accuracy, static anterior and lateral conformal fields as well as a 358° arc with a 10 cm circular aperture were delivered for each trajectory. The two‐dimensional (2D) geometric tracking error was measured as the difference between marker position and MLC aperture center in continuously acquired portal images. For dosimetric evaluation, VMAT treatment plans with high and low modulation were delivered to a biplanar diode array dosimeter using the same trajectories. Dose measurements with and without MLC tracking were compared to a static reference dose using 3%/3 mm and 2%/2 mm γ‐tests.Results: The overall tracking system latency was 172 ms. The mean 2D root‐mean‐square tracking error was 1.03 mm (0.80 mm prostate, 1.31 mm lung). MLC tracking improved the dose delivery in all cases with an overall reduction in the γ‐failure rate of 91.2% (3%/3 mm) and 89.9% (2%/2 mm) compared to no motion compensation. Low modulation VMAT plans had no (3%/3 mm) or minimal (2%/2 mm) residual γ‐failures while tracking reduced the γ‐failure rate from 17.4% to 2.8% (3%/3 mm) and from 33.9% to 6.5% (2%/2 mm) for plans with high modulation.Conclusions: Real‐time 4D ultrasound tracking was successfully integrated with online MLC tracking for the first time. The developed framework showed an accuracy and latency comparable with other MLC tracking methods while holding the potential to measure and adapt to target motion, including rotation and deformation, noninvasively.
- Open Access
- 1 September 2016
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 2 (1) , 409-413
An improved tracking framework for ultrasound probe localization in image-guided radiosurgery
Real-time target localization with ultrasound holds high potential for image guidance and motion compensation in radiosurgery due to its non-invasive image acquisition free from ionizing radiation. However, a two-step localization has to be performed when integrating ultrasound into the existing radiosurgery workflow. In addition to target localization inside the ultrasound volume, the probe itself has to be localized in order to transform the target position into treatment room coordinates. By adapting existing camera calibration tools, we have developed a method to extend the stereoscopic X-ray tracking system of a radiosurgery platform in order to locate objects such as marker geometries with six degrees of freedom. The calibration was performed with 0.1 mm reprojection error. By using the full area of the flat-panel detectors without pre-processing the extended software increased the tracking volume and resolution by up to 80%, substantially improving patient localization and marker detectability. Furthermore, marker-tracking showed sub-millimeter accuracy and rotational errors below 0.1°. This demonstrates that the developed extension framework can accurately localize marker geometries using an integrated X-ray system, establishing the link for the integration of real-time ultrasound image guidance into the existing system.
- 1 September 2016
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 2 (1) , 409-413
Open AccessAn improved tracking framework for ultrasound probe localization in image-guided radiosurgery
Real-time target localization with ultrasound holds high potential for image guidance and motion compensation in radiosurgery due to its non-invasive image acquisition free from ionizing radiation. However, a two-step localization has to be performed when integrating ultrasound into the existing radiosurgery workflow. In addition to target localization inside the ultrasound volume, the probe itself has to be localized in order to transform the target position into treatment room coordinates. By adapting existing camera calibration tools, we have developed a method to extend the stereoscopic X-ray tracking system of a radiosurgery platform in order to locate objects such as marker geometries with six degrees of freedom. The calibration was performed with 0.1 mm reprojection error. By using the full area of the flat-panel detectors without pre-processing the extended software increased the tracking volume and resolution by up to 80%, substantially improving patient localization and marker detectability. Furthermore, marker-tracking showed sub-millimeter accuracy and rotational errors below 0.1°. This demonstrates that the developed extension framework can accurately localize marker geometries using an integrated X-ray system, establishing the link for the integration of real-time ultrasound image guidance into the existing system.