Shuwei Mao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Shuwei Mao has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Yangbo Ye
Department of Mathematics, The University of Iowa, Iowa City, USA
2 shared publications - Ge Wang
Rensselaer Polytechnic Institute
1 shared publication - Jian-Feng Cai
Hong Kong University of Science and Technology
1 shared publication - Jiehua Zhu
Department of Mathematical Sciences, Georgia Southern University, Statesboro, USA
1 shared publication - Shujun Fu
Shandong University
1 shared publication - Wenxiang Cong
Department of Biomedical Engineering Rensselaer Polytechnic Institute Troy 12180 NY USA
1 shared publication
Latest Publications
- 3 June 2023
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 163, 107108
RFPNet: Reorganizing feature pyramid networks for medical image segmentation
- 3 June 2023
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 163, 107108
RFPNet: Reorganizing feature pyramid networks for medical image segmentation
- 19 October 2016
- Published by IOP Publishing in Inverse Problems
- Vol. 32 (11)
A framelet-based iterative maximum-likelihood reconstruction algorithm for spectral CT
Standard computed tomography (CT) cannot reproduce spectral information of an object. Hardware solutions include dual-energy CT which scans the object twice in different x-ray energy levels, and energy-discriminative detectors which can separate lower and higher energy levels from a single x-ray scan. In this paper, we propose a software solution and give an iterative algorithm that reconstructs an image with spectral information from just one scan with a standard energy-integrating detector. The spectral information obtained can be used to produce color CT images, spectral curves of the attenuation coefficient μ ( r , E ) at points inside the object, and photoelectric images, which are all valuable imaging tools in cancerous diagnosis. Our software solution requires no change on hardware of a CT machine. With the Shepp–Logan phantom, we have found that although the photoelectric and Compton components were not perfectly reconstructed, their composite effect was very accurately reconstructed as compared to the ground truth and the dual-energy CT counterpart. This means that our proposed method has an intrinsic benefit in beam hardening correction and metal artifact reduction. The algorithm is based on a nonlinear polychromatic acquisition model for x-ray CT. The key technique is a sparse representation of iterations in a framelet system. Convergence of the algorithm is studied. This is believed to be the first application of framelet imaging tools to a nonlinear inverse problem.
- 19 October 2016
- Published by IOP Publishing in Inverse Problems
- Vol. 32 (11)
A framelet-based iterative maximum-likelihood reconstruction algorithm for spectral CT
Standard computed tomography (CT) cannot reproduce spectral information of an object. Hardware solutions include dual-energy CT which scans the object twice in different x-ray energy levels, and energy-discriminative detectors which can separate lower and higher energy levels from a single x-ray scan. In this paper, we propose a software solution and give an iterative algorithm that reconstructs an image with spectral information from just one scan with a standard energy-integrating detector. The spectral information obtained can be used to produce color CT images, spectral curves of the attenuation coefficient μ ( r , E ) at points inside the object, and photoelectric images, which are all valuable imaging tools in cancerous diagnosis. Our software solution requires no change on hardware of a CT machine. With the Shepp–Logan phantom, we have found that although the photoelectric and Compton components were not perfectly reconstructed, their composite effect was very accurately reconstructed as compared to the ground truth and the dual-energy CT counterpart. This means that our proposed method has an intrinsic benefit in beam hardening correction and metal artifact reduction. The algorithm is based on a nonlinear polychromatic acquisition model for x-ray CT. The key technique is a sparse representation of iterations in a framelet system. Convergence of the algorithm is studied. This is believed to be the first application of framelet imaging tools to a nonlinear inverse problem.