Gábor Stelczer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Gábor Stelczer has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Norbert Mészáros
National Institute of Oncology, Centre of Radiotherapy, 7-9. Ráth György Str., 1122 Budapest, Hungary
5 shared publications Csaba Polgár
Center of Radiotherapy, National Institute of Oncology, Budapest, Hungary; Department of Oncology, Semmelweis University, Faculty of Medicine, Budapest, Hungary
3 shared publicationsTibor Major
Center of Radiotherapy, National Institute of Oncology, Budapest, Hungary; Department of Oncology, Semmelweis University, Faculty of Medicine, Budapest, Hungary
3 shared publications- Tibor Major
Radiotherapy Centre, National Institute of Oncology, Budapest, Hungary
3 shared publications - Csaba Polgár
Sugárterápiás Központ, Országos Onkológiai Intézet, Budapest, Hungary.
2 shared publications Csilla Pesznyák
Center of Radiotherapy, National Institute of Oncology, Budapest, Hungary; Institute of Nuclear Techniques, Budapest University of Technology and Economics, Budapest, Hungary
2 shared publications
Latest Publications
- Open Access
- 1 December 2020
- Published by Elsevier in The Breast
- Vol. 54, 222-228
Accelerated partial breast irradiation with 3-dimensional conformal and image-guided intensity-modulated radiotherapy following breast conserving surgery – 7-Year results of a phase II trial
- 1 December 2020
- Published by Elsevier in The Breast
- Vol. 54, 222-228
Open AccessAccelerated partial breast irradiation with 3-dimensional conformal and image-guided intensity-modulated radiotherapy following breast conserving surgery – 7-Year results of a phase II trial
- Open Access
- 19 January 2019
- Published by Walter de Gruyter GmbH in Radiology and Oncology
- Vol. 53 (1) , 123-130
External beam accelerated partial breast irradiation: dosimetric assessment of conformal and three different intensity modulated techniques
Background: The aim of the study was to evaluate and compare four different external beam radiotherapy techniques of accelerated partial breast irradiation (APBI) considering target coverage, dose to organs at risk and overall plan quality. The investigated techniques were three dimensional conformal radiotherapy (3D-CRT), “step and shoot” (SS) and “sliding window” (SW) intensity-modulated radiotherapy (IMRT), intensity-modulated arc therapy (RA). Patients and methods: CT scans of 40 APBI patients were selected for the study. The planning objectives were set up according to the international recommendations. Homogeneity, conformity and plan quality indices were calculated from volumetric and dosimetric parameters of target volumes and organs at risk. The total monitor units and feasibility were also investigated. Results: There were no significant differences in the coverage of the target volume between the techniques. The homogeneity indices of 3D-CRT, SS, SW and RA plans were 0.068, 0.074, 0.058 and 0.081, respectively. The conformation numbers were 0.60, 0.80, 0.82 and 0.89, respectively. The V 50% values of the ipsilateral breast for 3D-CRT, SS, SW and RA were 47.5%, 40.2%, 39.9% and 31.6%, respectively. The average V 10% and V 40% values of ipsilateral lung were 13.1%, 28.1%, 28%, 36% and 2.6%, 1.9%, 1.9%, 3%, respectively. The 3D-CRT technique provided the best heart protection, especially in the low dose region. All contralateral organs received low doses. The SW technique achieved the best plan quality index (PQI). Conclusions: Good target volume coverage and tolerable dose to the organs at risk are achievable with all four techniques. Taking into account all aspects, we recommend the SW IMRT technique for APBI.
- 19 January 2019
- Published by Walter de Gruyter GmbH in Radiology and Oncology
- Vol. 53 (1) , 123-130
Open AccessExternal beam accelerated partial breast irradiation: dosimetric assessment of conformal and three different intensity modulated techniques
Background: The aim of the study was to evaluate and compare four different external beam radiotherapy techniques of accelerated partial breast irradiation (APBI) considering target coverage, dose to organs at risk and overall plan quality. The investigated techniques were three dimensional conformal radiotherapy (3D-CRT), “step and shoot” (SS) and “sliding window” (SW) intensity-modulated radiotherapy (IMRT), intensity-modulated arc therapy (RA). Patients and methods: CT scans of 40 APBI patients were selected for the study. The planning objectives were set up according to the international recommendations. Homogeneity, conformity and plan quality indices were calculated from volumetric and dosimetric parameters of target volumes and organs at risk. The total monitor units and feasibility were also investigated. Results: There were no significant differences in the coverage of the target volume between the techniques. The homogeneity indices of 3D-CRT, SS, SW and RA plans were 0.068, 0.074, 0.058 and 0.081, respectively. The conformation numbers were 0.60, 0.80, 0.82 and 0.89, respectively. The V 50% values of the ipsilateral breast for 3D-CRT, SS, SW and RA were 47.5%, 40.2%, 39.9% and 31.6%, respectively. The average V 10% and V 40% values of ipsilateral lung were 13.1%, 28.1%, 28%, 36% and 2.6%, 1.9%, 1.9%, 3%, respectively. The 3D-CRT technique provided the best heart protection, especially in the low dose region. All contralateral organs received low doses. The SW technique achieved the best plan quality index (PQI). Conclusions: Good target volume coverage and tolerable dose to the organs at risk are achievable with all four techniques. Taking into account all aspects, we recommend the SW IMRT technique for APBI.
- 15 June 2016
- Vol. 60 (4) , 305-311
[Dosimetric comparison of different techniques for external beam accelerated partial breast irradiation].
The aim of this article is to evaluate and compare four different radiotherapy techniques of accelerated partial breast irradiation (APBI) considering planning quality, dosimetric and practical aspects. The investigated techniques are three dimensional conformal radiotherapy (3D-CRT), "step and shoot" (SS) and "sliding window" (SW) intensity-modulated radiotherapy, intensity-modulated arc therapy (RA). CT scans of 10 patients previously treated with APBI were selected for the study. Surgical clips were placed on the borders of the tumour bed during breast conserving surgery. Target volume (PTV) was defined as enlarged CTV, which was created from the tumour bed through volume expansion using individual margins. Planning objectives were set up according to the international recommendations. Non-coplanar fields were used only for the 3D-CRT plans. For each plan homogeneity, conformity and plan quality indices were calculated from volumetric and dosimetric parameters of target volumes and organs at risk. The total monitor units and feasibility were also investigated. There was no significant difference in the coverage of the target volume by the prescribed dose between the techniques. SW plans were significantly more homogeneous (HI=0.033) than the 3D-CRT (HI=0.057) and the RA (HI=0.073) plans. The homogeneity of the SS technique (HI=0.053) did not differ significantly compared to others. The conformity of the 3D-CRT technique was significantly worse (CN=0.62) than that of SS (CN=0.85), SW (CN=0.85) and RA (CN=0.86) plans. There was a significant difference between RA (29.4%) and 3D-CRT (44.1%) and SW (35.6%) plans in the V50% of the ipsilateral breast. Mean V10% of the ipsilateral lung in 3D-CRT (10.1%) plans was significantly lower than in SS (34.3%), SW (34.3%) and RA (35.3%) plans. 3D-CRT technique provided the best heart protection. The shortest treatment times were achieved with RA technique. Good target volume coverage and tolerable dose to the organs at risk are achievable with all four techniques. Taking into account all the aspects, we recommend the sliding window IMRT technique for accelerated partial breast irradiation.
- 15 June 2016
- Vol. 60 (4) , 305-311
[Dosimetric comparison of different techniques for external beam accelerated partial breast irradiation].
The aim of this article is to evaluate and compare four different radiotherapy techniques of accelerated partial breast irradiation (APBI) considering planning quality, dosimetric and practical aspects. The investigated techniques are three dimensional conformal radiotherapy (3D-CRT), "step and shoot" (SS) and "sliding window" (SW) intensity-modulated radiotherapy, intensity-modulated arc therapy (RA). CT scans of 10 patients previously treated with APBI were selected for the study. Surgical clips were placed on the borders of the tumour bed during breast conserving surgery. Target volume (PTV) was defined as enlarged CTV, which was created from the tumour bed through volume expansion using individual margins. Planning objectives were set up according to the international recommendations. Non-coplanar fields were used only for the 3D-CRT plans. For each plan homogeneity, conformity and plan quality indices were calculated from volumetric and dosimetric parameters of target volumes and organs at risk. The total monitor units and feasibility were also investigated. There was no significant difference in the coverage of the target volume by the prescribed dose between the techniques. SW plans were significantly more homogeneous (HI=0.033) than the 3D-CRT (HI=0.057) and the RA (HI=0.073) plans. The homogeneity of the SS technique (HI=0.053) did not differ significantly compared to others. The conformity of the 3D-CRT technique was significantly worse (CN=0.62) than that of SS (CN=0.85), SW (CN=0.85) and RA (CN=0.86) plans. There was a significant difference between RA (29.4%) and 3D-CRT (44.1%) and SW (35.6%) plans in the V50% of the ipsilateral breast. Mean V10% of the ipsilateral lung in 3D-CRT (10.1%) plans was significantly lower than in SS (34.3%), SW (34.3%) and RA (35.3%) plans. 3D-CRT technique provided the best heart protection. The shortest treatment times were achieved with RA technique. Good target volume coverage and tolerable dose to the organs at risk are achievable with all four techniques. Taking into account all the aspects, we recommend the sliding window IMRT technique for accelerated partial breast irradiation.
- 25 May 2016
- Vol. 60 (4) , 299-304
[Investigating the clinical applicability of EBT2 self-developing films].
The purpose of the study was to investigate the physical properties of the EBT2 radiochromic films and define the conditions of its clinical applicability. We irradiated the films with different treatment techniques 3D conformal (3DCRT), intensity-modulated (IMRT) and stereotactic body radiotherapy with arc therapy (SBRT), and then compared the data with the dose distribution exported from the treatment planning system (Eclipse). Two film analysis softwares were investigated for the comparison: PTW Mephysto and FilmQA Pro. The comparisons of dose distributions were performed with gamma analysis, and the gamma criterion was 3%, 3mm, and 2%, 2mm. The gamma analysis results by the two programs were the following, (PTW/FilmQA Pro) with 3%, 3mm gamma criterion: 3DCRT (95,5/100%), IMRT (97/99,9%), SBRT (99,7/100%). In case of 2%, 2mm the results were: 3DCRT (87,1/98,9%), IMRT (92/98,5%), SBRT (96,7/97,9%). Based on the results it can be stated that during proper use, the features of the scanner do not affect the results. Both evaluation softwares are suitable for calibrating and evaluating films, moreover, performing the gamma analysis. The EBT2 film is suitable for the two-dimensional controlling of radiation therapy plans.
- 25 May 2016
- Vol. 60 (4) , 299-304
[Investigating the clinical applicability of EBT2 self-developing films].
The purpose of the study was to investigate the physical properties of the EBT2 radiochromic films and define the conditions of its clinical applicability. We irradiated the films with different treatment techniques 3D conformal (3DCRT), intensity-modulated (IMRT) and stereotactic body radiotherapy with arc therapy (SBRT), and then compared the data with the dose distribution exported from the treatment planning system (Eclipse). Two film analysis softwares were investigated for the comparison: PTW Mephysto and FilmQA Pro. The comparisons of dose distributions were performed with gamma analysis, and the gamma criterion was 3%, 3mm, and 2%, 2mm. The gamma analysis results by the two programs were the following, (PTW/FilmQA Pro) with 3%, 3mm gamma criterion: 3DCRT (95,5/100%), IMRT (97/99,9%), SBRT (99,7/100%). In case of 2%, 2mm the results were: 3DCRT (87,1/98,9%), IMRT (92/98,5%), SBRT (96,7/97,9%). Based on the results it can be stated that during proper use, the features of the scanner do not affect the results. Both evaluation softwares are suitable for calibrating and evaluating films, moreover, performing the gamma analysis. The EBT2 film is suitable for the two-dimensional controlling of radiation therapy plans.
- 11 March 2015
- Vol. 59 (2) , 111-8
[Accelerated partial breast irradiation with image-guided intensity-modulated radiotherapy following breast-conserving surgery - preliminary results of a phase II clinical study].
The purpose of the study was to implement accelerated partial breast irradiation (APBI) by means of image-guided intensity-modulated radiotherapy (IG-IMRT) following breast-conserving surgery (BCS) for low-risk early invasive breast cancer. Between July 2011 and March 2014, 60 patients with low-risk early invasive (St I-II) breast cancer who underwent BCS were enrolled in our phase II prospective study. Postoperative APBI was given by means of step and shoot IG-IMRT using 4 to 5 fields to a total dose of 36.9 Gy (9×4.1 Gy) using a twice-a-day fractionation. Before each fraction, series of CT images were taken from the region of the target volume using a kV CT on-rail mounted in the treatment room. An image fusion software was used for automatic image registration of the planning and verification CT images. Patient set-up errors were detected in three directions (LAT, LONG, VERT), and inaccuracies were adjusted by automatic movements of the treatment table. Breast cancer related events, acute and late toxicities, and cosmetic results were registered and analysed. At a median follow-up of 24 months (range 12-44) neither locoregional nor distant failure was observed. Grade 1 (G1), G2 erythema, G1 oedema, and G1 and G2 pain occurred in 21 (35%), 2 (3.3%), 23 (38.3%), 6 (10%) and 2 (3.3%) patients, respectively. No G3-4 acute side effects were detected. Among late radiation side effects G1 pigmentation, G1 fibrosis, and G1 fat necrosis occurred in 5 (8.3%), 7 (11.7%), and 2 (3.3%) patients, respectively. No ≥G2 late toxicity was detected. Excellent and good cosmetic outcome was detected in 45 (75%) and 15 (25%) patients. IG-IMRT is a reproducible and feasible technique for the delivery of APBI following conservative surgery for the treatment of low-risk, early-stage invasive breast carcinoma. Preliminary results are promising, early radiation side effects are minimal, and cosmetic results are excellent.
- 11 March 2015
- Vol. 59 (2) , 111-8
[Accelerated partial breast irradiation with image-guided intensity-modulated radiotherapy following breast-conserving surgery - preliminary results of a phase II clinical study].
The purpose of the study was to implement accelerated partial breast irradiation (APBI) by means of image-guided intensity-modulated radiotherapy (IG-IMRT) following breast-conserving surgery (BCS) for low-risk early invasive breast cancer. Between July 2011 and March 2014, 60 patients with low-risk early invasive (St I-II) breast cancer who underwent BCS were enrolled in our phase II prospective study. Postoperative APBI was given by means of step and shoot IG-IMRT using 4 to 5 fields to a total dose of 36.9 Gy (9×4.1 Gy) using a twice-a-day fractionation. Before each fraction, series of CT images were taken from the region of the target volume using a kV CT on-rail mounted in the treatment room. An image fusion software was used for automatic image registration of the planning and verification CT images. Patient set-up errors were detected in three directions (LAT, LONG, VERT), and inaccuracies were adjusted by automatic movements of the treatment table. Breast cancer related events, acute and late toxicities, and cosmetic results were registered and analysed. At a median follow-up of 24 months (range 12-44) neither locoregional nor distant failure was observed. Grade 1 (G1), G2 erythema, G1 oedema, and G1 and G2 pain occurred in 21 (35%), 2 (3.3%), 23 (38.3%), 6 (10%) and 2 (3.3%) patients, respectively. No G3-4 acute side effects were detected. Among late radiation side effects G1 pigmentation, G1 fibrosis, and G1 fat necrosis occurred in 5 (8.3%), 7 (11.7%), and 2 (3.3%) patients, respectively. No ≥G2 late toxicity was detected. Excellent and good cosmetic outcome was detected in 45 (75%) and 15 (25%) patients. IG-IMRT is a reproducible and feasible technique for the delivery of APBI following conservative surgery for the treatment of low-risk, early-stage invasive breast carcinoma. Preliminary results are promising, early radiation side effects are minimal, and cosmetic results are excellent.