Samuel Hammer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Samuel Hammer has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
G. Konrad
Institut für Umweltphysik (IUP), Heidelberg University, Germany
3 shared publicationsD. W. T. Griffith
School of Chemistry, University of Wollongong, Wollongong, Australia
2 shared publications- Felix Vogel
Climate Research Division, Environment and Climate Change Canada (ECCC), Toronto, ON, M3H 5T4, Canada
2 shared publications I. Levin
Institut für Umweltphysik, University of Heidelberg, Heidelberg, Germany
2 shared publicationsA. Jordan
Max-Planck Institute for Biogeochemistry, Jena, Germany
1 shared publication- Alex Vermeulen
ICOS ERIC - Carbon Portal, Department of Physical Geography and Ecosystem Sciences, Lund University, Lund, 22362, Sweden
1 shared publication
Latest Publications
- 29 March 2024
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 383 (6690) , 1417
Ingeborg Levin (1953—2024)
Ingeborg Levin, groundbreaking physicist who helped quantify the carbon cycle and greenhouse gas emissions, died on 10 February. She was 70. Ingeborg established high-quality long-term measurements to identify the radiocarbon present in carbon dioxide and inform estimates of carbon fluxes. In the late 1970s, climate change and greenhouse gases were far from a mainstream interest, but Ingeborg immediately recognized their importance and the crucial role science would play in informing policy. She also realized early on that the carbon-14 (C-14) introduced into the atmosphere by nuclear weapons testing presented a singular opportunity to understand how carbon moves from the atmosphere into other carbon reservoirs, such as the biosphere, soils, and oceans.
- 29 March 2024
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 383 (6690) , 1417
Ingeborg Levin (1953—2024)
Ingeborg Levin, groundbreaking physicist who helped quantify the carbon cycle and greenhouse gas emissions, died on 10 February. She was 70. Ingeborg established high-quality long-term measurements to identify the radiocarbon present in carbon dioxide and inform estimates of carbon fluxes. In the late 1970s, climate change and greenhouse gases were far from a mainstream interest, but Ingeborg immediately recognized their importance and the crucial role science would play in informing policy. She also realized early on that the carbon-14 (C-14) introduced into the atmosphere by nuclear weapons testing presented a singular opportunity to understand how carbon moves from the atmosphere into other carbon reservoirs, such as the biosphere, soils, and oceans.
- 19 September 2016
- Published by Cambridge University Press (CUP) in Radiocarbon
- Vol. 59 (3) , 875-883
Compatibility of Atmospheric 14CO2 Measurements: Comparing the Heidelberg Low-Level Counting Facility to International Accelerator Mass Spectrometry (AMS) Laboratories
Combining atmospheric Δ14CO2 data sets from different networks or laboratories requires secure knowledge on their compatibility. In the present study, we compare Δ14CO2 results from the Heidelberg low-level counting (LLC) laboratory to 12 international accelerator mass spectrometry (AMS) laboratories using distributed aliquots of five pure CO2 samples. The averaged result of the LLC laboratory has a measurement bias of –0.3±0.5‰ with respect to the consensus value of the AMS laboratories for the investigated atmospheric Δ14C range of 9.6 to 40.4‰. Thus, the LLC measurements on average are not significantly different from the AMS laboratories, and the most likely measurement bias is smaller than the World Meteorological Organization (WMO) interlaboratory compatibility goal for Δ14CO2 of 0.5‰. The number of intercomparison samples was, however, too small to determine whether the measurement biases of the individual AMS laboratories fulfilled the WMO goal.
- 19 September 2016
- Published by Cambridge University Press (CUP) in Radiocarbon
- Vol. 59 (3) , 875-883
Compatibility of Atmospheric 14CO2 Measurements: Comparing the Heidelberg Low-Level Counting Facility to International Accelerator Mass Spectrometry (AMS) Laboratories
Combining atmospheric Δ14CO2 data sets from different networks or laboratories requires secure knowledge on their compatibility. In the present study, we compare Δ14CO2 results from the Heidelberg low-level counting (LLC) laboratory to 12 international accelerator mass spectrometry (AMS) laboratories using distributed aliquots of five pure CO2 samples. The averaged result of the LLC laboratory has a measurement bias of –0.3±0.5‰ with respect to the consensus value of the AMS laboratories for the investigated atmospheric Δ14C range of 9.6 to 40.4‰. Thus, the LLC measurements on average are not significantly different from the AMS laboratories, and the most likely measurement bias is smaller than the World Meteorological Organization (WMO) interlaboratory compatibility goal for Δ14CO2 of 0.5‰. The number of intercomparison samples was, however, too small to determine whether the measurement biases of the individual AMS laboratories fulfilled the WMO goal.
- Open Access
- 14 May 2013
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 6 (5) , 1201-1216
Feasibility study of using a "travelling" CO2 and CH4 instrument to validate continuous in situ measurement stations
In the course of the ICOS (Integrated Carbon Observation System) Demonstration Experiment a feasibility study on the usefulness of a travelling comparison instrument (TCI) was conducted in order to evaluate continuous atmospheric CO2 and CH4 measurements at two European stations. The aim of the TCI is to independently measure ambient air in parallel to the standard station instrumentation, thus providing a comprehensive comparison that includes the sample intake system, the instrument itself as well as its calibration and data evaluation. Observed differences between the TCI and a gas chromatographic system, which acted as a reference for the TCI, were −0.02 ± 0.08 μmol mol−1 for CO2 and −0.3 ± 2.3 nmol mol−1 for CH4. Over a period of two weeks each, the continuous CO2 and CH4 measurements at two ICOS field stations, Cabauw (CBW), the Netherlands and Houdelaincourt (Observatoire Pérenne de l'Environnement, OPE), France, were compared to co-located TCI measurements. At Cabauw mean differences of 0.21 ± 0.06 μmol mol−1 for CO2 and 0.41 ± 0.50 nmol mol−1 for CH4 were found. For OPE the mean differences were 0.13 ± 0.07 μmol mol−1 for CO2 and 0.44 ± 0.36 nmol mol−1 for CH4. Offsets arising from differences in the working standard calibrations or leakages/contaminations in the drying systems are too small to explain the observed differences. Hence the most likely causes of these observed differences are leakages or contaminations in the intake lines and/or their flushing pumps. For the Cabauw instrument an additional error contribution originates from insufficient flushing of standard gases. Although the TCI is an extensive quality control approach it cannot replace other quality control systems. Thus, a comprehensive quality management strategy for atmospheric monitoring networks is proposed as well.
- 14 May 2013
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 6 (5) , 1201-1216
Open AccessFeasibility study of using a "travelling" CO2 and CH4 instrument to validate continuous in situ measurement stations
In the course of the ICOS (Integrated Carbon Observation System) Demonstration Experiment a feasibility study on the usefulness of a travelling comparison instrument (TCI) was conducted in order to evaluate continuous atmospheric CO2 and CH4 measurements at two European stations. The aim of the TCI is to independently measure ambient air in parallel to the standard station instrumentation, thus providing a comprehensive comparison that includes the sample intake system, the instrument itself as well as its calibration and data evaluation. Observed differences between the TCI and a gas chromatographic system, which acted as a reference for the TCI, were −0.02 ± 0.08 μmol mol−1 for CO2 and −0.3 ± 2.3 nmol mol−1 for CH4. Over a period of two weeks each, the continuous CO2 and CH4 measurements at two ICOS field stations, Cabauw (CBW), the Netherlands and Houdelaincourt (Observatoire Pérenne de l'Environnement, OPE), France, were compared to co-located TCI measurements. At Cabauw mean differences of 0.21 ± 0.06 μmol mol−1 for CO2 and 0.41 ± 0.50 nmol mol−1 for CH4 were found. For OPE the mean differences were 0.13 ± 0.07 μmol mol−1 for CO2 and 0.44 ± 0.36 nmol mol−1 for CH4. Offsets arising from differences in the working standard calibrations or leakages/contaminations in the drying systems are too small to explain the observed differences. Hence the most likely causes of these observed differences are leakages or contaminations in the intake lines and/or their flushing pumps. For the Cabauw instrument an additional error contribution originates from insufficient flushing of standard gases. Although the TCI is an extensive quality control approach it cannot replace other quality control systems. Thus, a comprehensive quality management strategy for atmospheric monitoring networks is proposed as well.
- Open Access
- 7 May 2013
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 6 (5) , 1153-1170
Assessment of a multi-species in situ FTIR for precise atmospheric greenhouse gas observations
We thoroughly evaluate the performance of a multi-species, in situ Fourier transform infrared (FTIR) analyser with respect to high-accuracy needs for greenhouse gas monitoring networks. The in situ FTIR analyser is shown to measure CO2, CO, CH4 and N2O mole fractions continuously, all with better reproducibility than the inter-laboratory compatibility (ILC) goals, requested by the World Meteorological Organization (WMO) for the Global Atmosphere Watch (GAW) programme. Simultaneously determined δ13CO2 reaches reproducibility as good as 0.03‰. Second-order dependencies between the measured components and the thermodynamic properties of the sample, (temperature, pressure and flow rate) and the cross sensitivities among the sample constituents are investigated and quantified. We describe an improved sample delivery and control system that minimises the pressure and flow rate variations, making post-processing corrections for those quantities non-essential. Temperature disequilibrium effects resulting from the evacuation of the sample cell are quantified and improved by the usage of a faster temperature sensor. The instrument has proven to be linear for all measured components in the ambient concentration range. The temporal stability of the instrument is characterised on different time scales. Instrument drifts on a weekly time scale are only observed for CH4 (0.04 nmol mol−1 day−1) and δ13CO2 (0.02‰ day−1). Based on 10 months of continuously collected quality control measures, the long-term reproducibility of the instrument is estimated to ±0.016 μmol mol−1 CO2, ±0.03‰ δ13CO2, ±0.14 nmol mol−1 CH4, ±0.1 nmol mol−1 CO and ±0.04 nmol mol−1 N2O. We propose a calibration and quality control scheme with weekly calibrations of the instrument that is sufficient to reach WMO-GAW inter-laboratory compatibility goals.
- 7 May 2013
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 6 (5) , 1153-1170
Open AccessAssessment of a multi-species in situ FTIR for precise atmospheric greenhouse gas observations
We thoroughly evaluate the performance of a multi-species, in situ Fourier transform infrared (FTIR) analyser with respect to high-accuracy needs for greenhouse gas monitoring networks. The in situ FTIR analyser is shown to measure CO2, CO, CH4 and N2O mole fractions continuously, all with better reproducibility than the inter-laboratory compatibility (ILC) goals, requested by the World Meteorological Organization (WMO) for the Global Atmosphere Watch (GAW) programme. Simultaneously determined δ13CO2 reaches reproducibility as good as 0.03‰. Second-order dependencies between the measured components and the thermodynamic properties of the sample, (temperature, pressure and flow rate) and the cross sensitivities among the sample constituents are investigated and quantified. We describe an improved sample delivery and control system that minimises the pressure and flow rate variations, making post-processing corrections for those quantities non-essential. Temperature disequilibrium effects resulting from the evacuation of the sample cell are quantified and improved by the usage of a faster temperature sensor. The instrument has proven to be linear for all measured components in the ambient concentration range. The temporal stability of the instrument is characterised on different time scales. Instrument drifts on a weekly time scale are only observed for CH4 (0.04 nmol mol−1 day−1) and δ13CO2 (0.02‰ day−1). Based on 10 months of continuously collected quality control measures, the long-term reproducibility of the instrument is estimated to ±0.016 μmol mol−1 CO2, ±0.03‰ δ13CO2, ±0.14 nmol mol−1 CH4, ±0.1 nmol mol−1 CO and ±0.04 nmol mol−1 N2O. We propose a calibration and quality control scheme with weekly calibrations of the instrument that is sufficient to reach WMO-GAW inter-laboratory compatibility goals.
- Open Access
- 22 May 2012
- Published by Copernicus GmbH in EGUsphere
- Vol. 6 (5) , 1153-1170
Assessment of a multi-species in-situ FTIR for precise atmospheric greenhouse gas observations
We thoroughly evaluate the performance of a multi-species, in-situ FTIR analyser with respect to high accuracy needs for greenhouse gas monitoring networks. The in-situ FTIR analyser measures CO2, CO, CH4 and N2O mole fractions continuously, all with better reproducibility than requested by the WMO-GAW inter-laboratory compatibility (ILC) goal. Simultaneously determined δ13CO2 reaches reproducibility as good as 0.03‰. This paper focuses on the quantification of residual dependencies between the measured components and the thermodynamic properties of the sample as well as the cross-sensitivities among the sample constituents. The instrument has proven to be linear for all components in the ambient range. The temporal stability of the instrument was investigated by 10 months of continuously collected quality control measures. Based on these measures we conclude that for moderately stable laboratory conditions weekly calibrations of the instrument are sufficient to reach WMO-GAW ILC goals.
- 22 May 2012
- Published by Copernicus GmbH in EGUsphere
- Vol. 6 (5) , 1153-1170
Open AccessAssessment of a multi-species in-situ FTIR for precise atmospheric greenhouse gas observations
We thoroughly evaluate the performance of a multi-species, in-situ FTIR analyser with respect to high accuracy needs for greenhouse gas monitoring networks. The in-situ FTIR analyser measures CO2, CO, CH4 and N2O mole fractions continuously, all with better reproducibility than requested by the WMO-GAW inter-laboratory compatibility (ILC) goal. Simultaneously determined δ13CO2 reaches reproducibility as good as 0.03‰. This paper focuses on the quantification of residual dependencies between the measured components and the thermodynamic properties of the sample as well as the cross-sensitivities among the sample constituents. The instrument has proven to be linear for all components in the ambient range. The temporal stability of the instrument was investigated by 10 months of continuously collected quality control measures. Based on these measures we conclude that for moderately stable laboratory conditions weekly calibrations of the instrument are sufficient to reach WMO-GAW ILC goals.
- Open Access
- 1 November 2010
- Published by Stockholm University Press in Tellus B: Chemical and Physical Meteorology
- Vol. 62 (5)
Implication of weekly and diurnal14C calibration on hourly estimates of CO-based fossil fuel CO2at a moderately polluted site in southwestern Germany
A 7-year-long data set of integrated high-precision 14CO2 observations combined with occasional hourly 14CO2 flask data from the Heidelberg sampling site is presented. Heidelberg is located in the highly populated and industrialized upper Rhine valley in southwestern Germany. The 14CO2 data are used in combination with hourly carbon monoxide (CO) observations to estimate regional hourly fossil fuel CO2 (ΔFFCO2) mixing ratios. We investigate three different 14C calibration schemes to calculate ΔFFCO2: (1) the long-term median ΔCO/ΔFFCO2 ratio of 14.6 ppb ppm-1 (mean: 15.5 ± 5.6 ppb ppm-1), (2) individual (2-)week-long integrated ΔCO/ΔFFCO2 ratios, which take into account the large week-to-week variability of ±5.6 ppb ppm-1 (1σ; interquartile range: 5.5 ppb ppm-1), and (3) a calibration which also includes diurnal changes of the ΔCO/ΔFFCO2 ratio. We show that in winter a diurnally changing ΔCO/ΔFFCO2 ratio provides a much better agreement with the direct 14C-based hourly ΔFFCO2 estimates whereas summer values are not significantly improved with a diurnal calibration. Using integrated 14CO2 samples to determine weekly mean ΔCO/ΔFFCO2 ratios introduces a bias in the CO-based ΔFFCO2 estimates which can be corrected for with diurnal grab sample data. Altogether our 14C-calibrated CO-based method allows determining ΔFFCO2 at a semi-polluted site with a precision of approximately ±25%. DOI: 10.1111/j.1600-0889.2010.00477.x
- 1 November 2010
- Published by Stockholm University Press in Tellus B: Chemical and Physical Meteorology
- Vol. 62 (5)
Open AccessImplication of weekly and diurnal14C calibration on hourly estimates of CO-based fossil fuel CO2at a moderately polluted site in southwestern Germany
A 7-year-long data set of integrated high-precision 14CO2 observations combined with occasional hourly 14CO2 flask data from the Heidelberg sampling site is presented. Heidelberg is located in the highly populated and industrialized upper Rhine valley in southwestern Germany. The 14CO2 data are used in combination with hourly carbon monoxide (CO) observations to estimate regional hourly fossil fuel CO2 (ΔFFCO2) mixing ratios. We investigate three different 14C calibration schemes to calculate ΔFFCO2: (1) the long-term median ΔCO/ΔFFCO2 ratio of 14.6 ppb ppm-1 (mean: 15.5 ± 5.6 ppb ppm-1), (2) individual (2-)week-long integrated ΔCO/ΔFFCO2 ratios, which take into account the large week-to-week variability of ±5.6 ppb ppm-1 (1σ; interquartile range: 5.5 ppb ppm-1), and (3) a calibration which also includes diurnal changes of the ΔCO/ΔFFCO2 ratio. We show that in winter a diurnally changing ΔCO/ΔFFCO2 ratio provides a much better agreement with the direct 14C-based hourly ΔFFCO2 estimates whereas summer values are not significantly improved with a diurnal calibration. Using integrated 14CO2 samples to determine weekly mean ΔCO/ΔFFCO2 ratios introduces a bias in the CO-based ΔFFCO2 estimates which can be corrected for with diurnal grab sample data. Altogether our 14C-calibrated CO-based method allows determining ΔFFCO2 at a semi-polluted site with a precision of approximately ±25%. DOI: 10.1111/j.1600-0889.2010.00477.x