  • Technical Note: Experimental verification of EGS nrc calculated depth dose within a parallel magnetic field in a lung phantom

    by Andrei Ghila, B. Gino Fallone, Satyapal Rathee

    Purpose The calculation of depth doses from a 6 MV photon beam in polystyrene using EGSnrc Monte Carlo, within a parallel magnetic field, has been previously verified against measured data. The current work experimentally investigates the accuracy of EGSnrc calculated depth doses in lung within the same parallel magnetic field. Methods Two cylindrical bore electromagnets produced a magnetic field parallel to the central axis of a Varian Silhouette beam. A Gammex lung phantom was used, along with a parallel plate ion chamber, for the depth dose measurements. Two experimental setups were investigated: top of phantom coinciding with the top of the magnet's bore, and top of phantom coinciding with the centre of the bore. EGSnrc was minimally modified to read the 3D magnetic field distribution and then used to simulate the depth dose in lung. Results The parallel magnetic field caused measurable increases in dose at the surface and in the buildup region for both setups. For the setup where the top of the lung phantom coincides with the top of the magnet, the surface dose increased by ~11% compared to the no magnetic field case but the depth of maximum dose remained unchanged. When the phantom's top surface coincided with the center of the magnet, the surface dose increased by 32% and dose maximum occurred at a shallower depth. EGSnrc was able to calculate these dose increases due to the magnetic field accurately for both setups. All the simulated depth dose values were within 2% (with respect to Dmax) of the measured ones, and most of the investigated points were within 1.5%. Conclusions Surface and dose increases due to a parallel magnetic field have been measured in a lung phantom at two separate locations within the magnetic field. EGSnrc has been shown to match these measurements to within 2%.


  • Open Access

    Experimental verification of EGSnrc Monte Carlo calculated depth doses within a realistic parallel magnetic field in a polystyrene phantom

    by Andrei Ghila, Stephen Steciw, B. Gino Fallone, Satyapal Rathee

    Integrating a linac with a magnetic resonance imager (MRI) will revolutionize the accuracy of external beam radiation treatments. Irradiating in the presence of a strong magnetic field, however, will modify the dose distribution. These dose modifications have been investigated previously, mainly using Monte Carlo simulations. The purpose of this work is to experimentally verify the use of the EGSnrc Monte Carlo (MC) package for calculating percent depth doses (PDDs) in a homogeneous phantom, in the presence of a realistic parallel magnetic field. Two cylindrical electromagnets were used to produce a 0.207 T magnetic field parallel to the central axis of a 6 MV photon beam from a clinical linac. The magnetic field was measured at discrete points along orthogonal axes, and these measurements were used to validate a full 3D magnetic field map generated using COMSOL Multiphysics. Using a small parallel plate ion chamber, the depth dose was measured in a polystyrene phantom placed inside the electromagnet bore at two separate locations: phantom top surface coinciding with top of bore, and phantom top surface coinciding with center of bore. BEAMnrc MC was used to model the linac head which was benchmarked against the linac's commissioning measurements. The depth dose in polystyrene was simulated using DOSXYZnrc MC. For the magnetic field case, the DOSXYZnrc code was slightly modified to implement the previously calculated 3D magnetic field map to be used in the standard electromagnetic macros. The calculated magnetic field matched the measurements within 2% of the maximum central field (0.207 T) with most points within the experimental uncertainty (1.5%). For the MC linac head model, over 93% of all simulated points passed the 2%, 2 mm γ acceptance criterion, when comparing measured and simulated lateral beam and depth dose profiles. The parallel magnetic field caused a surface dose increase, compared to the no magnetic field case, due to the Lorentz force confining contaminant electrons within the beam. The surface dose increase was measured to be approximately 10% (relative to no field Dmax) when the phantom surface coincided with the top of the electromagnet's bore. This effect was enhanced by moving the phantom surface to the center of the magnet's bore in relatively high magnetic field (> 0.13 T). The surface dose for this setup increased by 30% and the entire buildup region was affected. When the dimensions and composition of the ion chamber air cavity and entrance window were included, EGSnrc was able to accurately simulate these dose increases, both at the surface and in the buildup region. All the simulated points were within 1% of the measurements for both setups. The ferromagnetic linac head was determined to have a negligible effect on the final PDD comparison. Irradiating in the presence of a parallel magnetic field causes measurable surface and buildup depth dose increases. We have experimentally verified that the EGSnrc Monte Carlo package is able to accurately calculate the PDDs with these surface and buildup dose modifications in a homogeneous phantom.


  • Influence of standard RF coil materials on surface and buildup dose from a 6 MV photon beam in magnetic field

    by A. Ghila, B. G. Fallone, S. Rathee

    Purpose: Magnetic resonance guided teletherapy systems aspire to image the patient concurrently with the radiation delivery. Thus, the radiofrequency (RF) coils used for magnetic resonance imaging, placed on or close to patient skin and in close proximity to the treatment volume, would be irradiated leading to modifications of radiation dose to the skin and in the buildup region. The purpose of this work is to measure and assess these dose modifications due to standard off‐the‐shelf RF coil materials.Methods: A typical surface coil was approximated as layered sheets of polycarbonate, copper tape, and Teflon to emulate the base, conductor, and cover, respectively. A separate investigation used additional coil materials, such as copper pipe, plastic coil housing, a typical coil padding material, and a thin copper conductor. The materials were placed in the path of a 6 MV photon beam at various distances from polystyrene phantoms in which the surface and buildup doses were measured. The experiments were performed on a clinical Varian linac with no magnetic field and with a 0.21 T electromagnet producing a magnetic field parallel to the beam central axis. The authors repeated similar experiments in the presence of a 0.22 T magnetic field oriented perpendicular to the beam central axis using an earlier linac‐MR prototype, with a biplanar permanent magnet. The radiation detectors used for the measurements were two different parallel plate ion chambers and GAFChromic films.Results: A typical open beam surface dose of 20% (relative to open beam Dmax) was increased to 63% by the coil padding material and to >74% by all other materials when placed in direct contact with the phantom, irrespective of magnetic field presence or orientation. Without a magnetic field, the surface dose decreased as the test materials were moved away from the phantom surface toward the radiation source, reaching between 30% and 40% at 10 cm gap between the phantom and the test materials. In the presence of the transverse magnetic field, the surface dose reduction was more rapid reaching a dose level of 30%–40% with only 3–4 cm gap. In the presence of the parallel magnetic field, as expected, the surface dose did not decrease considerably as the gap between the phantom surface and test materials was increased; the surface dose remained >60% at 10 cm gap for all tested materials except for the thin copper conductor.Conclusions: As expected, placing coil materials in direct contact with the phantom surface increases the surface dose considerably. The surface dose is reduced by creating a gap between the coil materials and phantom surface. This dose reduction happens more rapidly in the presence of a transverse magnetic field. However, the surface dose stays relatively large irrespective of the gap in the presence of a parallel magnetic field. Thus, the standard, off‐the‐shelf RF coils should be used with caution in integrated linac‐MR systems, especially those using a parallel magnetic field orientation in which case the RF coils will probably need to be reconfigured to create open ports for the radiation beam.


  • Radiation induced current in the RF coils of integrated linac‐MR systems: The effect of buildup and magnetic field

    by Ben Burke, Andrei Ghila, B. G. Fallone, Satyapal Rathee

    In integrated linac-MRI systems, a measurable radiation induced current (RIC) is caused in RF coils by pulsed irradiation. This work (1) tests a buildup method of RIC removal in planar conductors; (2) validates a Monte Carlo method of RIC calculation in metal conductors; and (3) uses the Monte Carlo method to examine the effects of magnetic fields on both planar conductor and practical cylindrical coil geometries. The RIC was measured in copper and aluminum plates, taken as the RF coil conductor surrogates, as a function of increasing thickness of buildup materials (teflon and copper). Based on the Penelope Monte Carlo code, a method of RIC calculation was implemented and validated against measurements. This method was then used to calculate the RIC in cylindrical coil geometries with various air gaps between the coil conductor and the enclosed water phantom. Magnetic fields, both parallel and perpendicular to the radiation beam direction, were then included in the simulation program. The effect of magnetic fields on the effectiveness of RIC removal with the application of buildup material was examined in both the planar and the cylindrical geometries. Buildup reduced RIC in metal plate conductors. For copper detector∕copper buildup case, the RIC amplitude was reduced to zero value with 0.15 cm copper buildup. However, when the copper is replaced with teflon as buildup atop the copper conductor, the RIC was only reduced to 80% of its value at zero buildup since the true electronic equilibrium cannot be obtained in this case. For the aluminum detector∕teflon buildup case, the initial amplitude of the RIC was reduced by 90% and 92% in planar aluminum conductor and a surface coil, respectively. In case of cylindrical coils made of aluminum, teflon buildup around the coil's outer surface was generally effective but failed to remove RIC when there was an air gap between the coil and the phantom. Stronger magnetic fields (>0.5 T) perpendicular to the beam direction showed a modest decrease in the RIC for planar conductors with buildup. In the cylindrical geometries, the effect of magnetic fields was very small compared to the effect of introducing air gaps. Loss in signal-to-noise ratio (SNR) due to RIC was reduced from 11% to 5% when a simple buildup was applied to the solenoid in a preliminary experiment. The RIC in RF coils results from the lack of electronic equilibrium in the coil conductor as the RIC in planar conductor was completely removed by identical buildup of adequate thickness to create electronic equilibrium. The buildup method of RIC removal is effective in cylindrical coil geometry when the coil conductor is in direct contact with the patient. The presence of air makes this method of RIC removal less effective although placing buildup still reduces the RIC by up to 60%. The RIC Monte Carlo simulation is a useful tool for practical coil design where radiation effects must be considered. The SNR is improved in the images obtained concurrently withradiation if buildup is applied to the coil.