YZYu Zhang

Yu Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yu Zhang has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • Jiancang Su

    Science and Technology on High Power Microwave Laboratory Northwest Institute of Nuclear Technology P. O. Box 69 Branch 13 Xi'an 710024 People's Republic of China

    5 shared publications
  • Jie Cheng

    Science and Technology on High Power Microwave Laboratory Northwest Institute of Nuclear Technology P. O. Box 69 Branch 13 Xi'an 710024 People's Republic of China

    5 shared publications
  • Bo Zeng

    Science and Technology on High Power Microwave Laboratory Northwest Institute of Nuclear Technology P. O. Box 69 Branch 13 Xi'an 710024 People's Republic of China

    4 shared publications
  • Rui Li

    Science and Technology on High Power Microwave Laboratory Northwest Institute of Nuclear Technology P. O. Box 69 Branch 13 Xi'an 710024 People's Republic of China

    4 shared publications
  • Xudong Qiu

    Science and Technology on High Power Microwave Laboratory Northwest Institute of Nuclear Technology P. O. Box 69 Branch 13 Xi'an 710024 People's Republic of China

    4 shared publications
  • Binxiong Yu

    Science and Technology on High Power Microwave Laboratory Northwest Institute of Nuclear Technology P. O. Box 69 Branch 13 Xi'an 710024 People's Republic of China

    3 shared publications

Latest Publications

  • Open Access

    Time‐domain resonant characteristics between the disturbances and the RS422 communication signals in Tesla pulse driver, and analysis on the caused RS422 communication interference

    by Yu Zhang, Jie Cheng, Jiancang Su, Lei Zheng, Xudong Qiu, Wei Shang

    The communication circuit network is widely employed for signal transmission in high‐voltage pulse driver system, for commanding, controlling, measurement & communication. The electromagnetic compatibility of the communication circuit network mainly decides the stability and reliability of the high‐voltage pulse driver system. Aiming at the electromagnetic interference (EMI) problems of the RS422 communication circuit in the Tesla pulse driver, the generated disturbance sources and characteristics from the Tesla pulse driver itself are analysed in five divided work stages, and two typical simplified EMI coupling modes for the communication circuit are also presented in this Letter. In the RS422 communication cable circuits between the subsystems of the pulse driver, the time‐domain resonant characteristics of the communication signal and the conducting disturbances are analysed. The error and failure modes of the RS422 communication data caused by the full time‐domain conducting interference are also revealed. Evaluation and calculation method for the time‐domain resonant probability and the interference probability of the RS422 communication signals is also put forward. The communication interference probability is also calculated under different repetition work modes of the Tesla pulse driver. In view of the time‐domain resonance phenomenon, some effective ways for time‐domain resonance elimination and interference compression are put forward.


  • Open Access

    Analysis and elimination on common‐mode interferences generated in the series‐resonant converter system of high‐power Tesla pulse driver

    by Yu Zhang, Jiancang Su, Lei Zheng, Rui Li, Liang Zhao, Binxiong Yu, Jie Cheng, Bo Zeng, Xiudong Xu

    Here, the distributed parametric circuit model of the series‐resonant charge power source in Tesla pulse driver is built. The generation mechanisms and characteristics of three types of d U /d t interferences and one kind of d i /d t interference are analysed. The voltage ringing and its corresponding d U /d t generated on the shared parts of the main circuit play as the input common‐mode interference (CMI) to the driving and triggering circuits. Circuit simulation and tests were both carried out to get the characteristics of high‐frequency CMIs in different key points of the main circuit. The generation and conducting of the high frequency CMIs were mainly caused by the abrupt charge and discharge resonances of the distributed capacitors. CMI suppression methods were put forward and demonstrated, such as resistor‐capacitor absorption between the middle points of the converter H‐bridge, resistor‐capacitor grounding at the negative port of the input DC mother line, the negative port grounding of the load capacitor, and symmetrical layout of two L‐C resonant arms in the series‐resonant circuit. The voltage ringing, d U /d t and d i /d t interferences in the series‐resonant converter were all effectively suppressed by these methods.


  • The effects of cathode electrodeposited polymer film on the long vacuum gap breakdown

    by Yu Zhang, Jiancang Su, Xudong Qiu, Rui Li, Liang Zhao, Binxiong Yu, Jie Cheng, Bo Zeng, Xiudong Xu

    Vacuum surface discharge is one of the most important issues for vacuum insulation. In this paper, a method for breakdown field strength enhancement of long vacuum gap is put forward, through depositing polymer dielectric coating on the electrode surface. The physical mechanism that the polymer film changes the electrode surface state is analyzed. After a layer of polymer film is deposited on the electrode surface, the decreased surface field strength and improved micro-surface state both help to suppress the field electron emission from the cathode. The technique of cathode electrodeposition for high polymers such as epoxy resin (ER), epoxy acrylate (EA), polyimide (PI) and poly(ether-ether-ketone) (PEEK) was explored, and the thickness of the electrodeposited coating can reach 20–50 µm. The effects of the electrodeposited polymer coatings of electrodes on the 2.5 cm vacuum gap breakdown were studied under a high-voltage vacuum experiment platform. Experimental results showed that when ER, EA and PEEK coatings with thickness of 25–45 µm were respectively electrodeposited on the 95 cm2 plate cathode, the initial-breakdown field strengths of the 2.5 cm vacuum gap were enhanced by 20.7%–22.4%. The enhancement of the initial-breakdown field strength was restricted by the coating defects, grain boundary defects on the cathode surface, and the micro-triple-point emission after the fusing of some local coating points due to the electron bombardments.


  • Open Access

    Microsecond‐scale fast fusing and cutout characteristics of high current fuse

    by Yu Zhang, Jiancang Su, Lei Zheng, Rui Li, Binxiong Yu, Xudong Qiu, Bo Zeng, Jie Cheng, Xiudong Xu

    As to the problem that common high current fuses have a long cutout time at ms scale to protect the DC power source, an effective way for fast arc extinction and cutout of fuse is put forward in this study, based on the burst high‐pulse current discharge from a parallelly connected filter capacitor. Through increasing the discharge current from the filter capacitor, the total cutout time of fuse can be reduced from ms to 40 μs after the load of the DC800 V power source was shorted in experiment. The method for designing the crucial parameters of the short‐circuit fault protection in DC power source is also presented. Experimental results showed that the DC1500V/32A fuse with a single fuse body and solidified filling quartz sand can reduce the time before arc forms ( T f ) and total cutout time ( T e ) to 30 and 44 μs, respectively. The effects of the shorted load impedance on the DC power source protection are also studied. It showed that the dynamic short‐load impedances formed by the breakdown semiconductor parts in short‐circuit faults were T e of fuse was compressed in the range between 50 and 90 μs.


  • Open Access

    Micro-effects of surface polishing treatment on microscopic field enhancement and long vacuum gap breakdown

    by Yu Zhang, Jiancang Su, Xudong Qiu, Rui Li, Liang Zhao, Jie Cheng, Bo Zeng

    In this paper, three surface polishing treatments were employed to treat plate titanium electrodes, and microscopic surfaces of the electrodes after polishing were presented. Through comparing the breakdown strength of the 2.5 cm vacuum gap formed by plate titanium electrodes after the three treatments, experimental results showed that the breakdown strength was enhanced by 35% while the micro-surface roughness dropped from 3.5μm to 0.35μm. In view of that, effects of microstructural parameters after polishing on the microscopic field enhancement factor were investigated. The field-uniformity mechanism and the shield effect between micro-protrusions on the rough electrode surface were put forward and demonstrated. Based on the idea that electric field can be shield in a pit, a theoretical model was established to evaluate the maximum field enhancement factor βEmax on the micro-surface. It revealed that 1 ≤ βEmax ≤ 3.96, and βEmax had the maximum decrements of 1.96 and 2.1 both from 3.96 after the mirror polishing and the chemical polishing, respectively. When the surface roughness decreased to the scale from nm to μm, the effort on βEmax reduction through surface polishing was not effective to enhance the vacuum gap breakdown strength any more.