Tabrez Lakha
Research Subjects
Tabrez Lakha has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Mohit Kheur
Rangoonwala College of Dental Sciences and Research Centre
7 shared publications - Supriya Kheur
Department of Oral Pathology and Microbiology, Dr. D. Y. Patil Dental College and Hospital, Dr. D. Y. Patil Vidyapeeth, Pimpri, Pune, India
7 shared publications Bach Le
Univ Southern Calif, Herman Ostrow Sch Dent, Dept Oral & Maxillofacial Surg, Los Angeles, CA 90007 USA
4 shared publicationsMohit Kheur
MA Rangoonwala Coll Dent Sci & Res Ctr, Dept Prosthodont & Implantol, Azam Campus 2390-B,KB,Hidayatullah Rd, Pune 411001, Maharashtra, India
3 shared publicationsRamandeep Sandhu
Univ Toronto, Holland Bloorview Kids Rehabil Hosp, Dept Fixed Prosthodont, Toronto, ON, Canada
3 shared publicationsSupriya Kheur
Dr DY Patil Vidyapeeth Univ, Dr DY Patil Dent Coll & Hosp, Dept Oral Pathol & Microbiol, Pune, Maharashtra, India
3 shared publications
Latest Publications
- Open Access
- 26 February 2023
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 14 (3) , 130
In-Vitro Evaluation of Photofunctionalized Implant Surfaces in a High-Glucose Microenvironment Simulating Diabetics
The present study aimed to assess the efficacy of photofunctionalization on commercially available dental implant surfaces in a high-glucose environment. Discs of three commercially available implant surfaces were selected with various nano- and microstructural alterations (Group 1—laser-etched implant surface, Group 2—titanium–zirconium alloy surface, Group 3—air-abraded, large grit, acid-etched surface). They were subjected to photo-functionalization through UV irradiation for 60 and 90 min. X-ray photoelectron spectroscopy (XPS) was used to analyze the implant surface chemical composition before and after photo-functionalization. The growth and bioactivity of MG63 osteoblasts in the presence of photofunctionalized discs was assessed in cell culture medium containing elevated glucose concentration. The normal osteoblast morphology and spreading behavior were assessed under fluorescence and phase-contrast microscope. MTT (3-(4,5 Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) and alizarin red assay were performed to assess the osteoblastic cell viability and mineralization efficiency. Following photofunctionalization, all three implant groups exhibited a reduced carbon content, conversion of Ti4+ to Ti3+, increased osteoblastic adhesion, viability, and increased mineralization. The best osteoblastic adhesion in the medium with increased glucose was seen in Group 3. Photofunctionalization altered the implant surface chemistry by reducing the surface carbon content, probably rendering the surfaces more hydrophilic and conducive for osteoblastic adherence and subsequent mineralization in high-glucose environment.
- 26 February 2023
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 14 (3) , 130
Open AccessIn-Vitro Evaluation of Photofunctionalized Implant Surfaces in a High-Glucose Microenvironment Simulating Diabetics
The present study aimed to assess the efficacy of photofunctionalization on commercially available dental implant surfaces in a high-glucose environment. Discs of three commercially available implant surfaces were selected with various nano- and microstructural alterations (Group 1—laser-etched implant surface, Group 2—titanium–zirconium alloy surface, Group 3—air-abraded, large grit, acid-etched surface). They were subjected to photo-functionalization through UV irradiation for 60 and 90 min. X-ray photoelectron spectroscopy (XPS) was used to analyze the implant surface chemical composition before and after photo-functionalization. The growth and bioactivity of MG63 osteoblasts in the presence of photofunctionalized discs was assessed in cell culture medium containing elevated glucose concentration. The normal osteoblast morphology and spreading behavior were assessed under fluorescence and phase-contrast microscope. MTT (3-(4,5 Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) and alizarin red assay were performed to assess the osteoblastic cell viability and mineralization efficiency. Following photofunctionalization, all three implant groups exhibited a reduced carbon content, conversion of Ti4+ to Ti3+, increased osteoblastic adhesion, viability, and increased mineralization. The best osteoblastic adhesion in the medium with increased glucose was seen in Group 3. Photofunctionalization altered the implant surface chemistry by reducing the surface carbon content, probably rendering the surfaces more hydrophilic and conducive for osteoblastic adherence and subsequent mineralization in high-glucose environment.
- Open Access
A Comparative Study on Simulated Chairside Grinding and Polishing of Monolithic Zirconia
This study evaluated the effects of different simulated chairside grinding and polishing protocols on the physical and mechanical properties of surface roughness, hardness, and flexural strength of monolithic zirconia. Sintered monolithic zirconia specimens (15 mm × 3 mm × 3 mm) were abraded using three different burs: diamond bur, modified diamond bur (zirconia specified), and tungsten carbide bur, along with a group of unprepared specimens that served as a control group. The study was divided into two phases, Phase 1 and Phase 2. Surface roughness, surface hardness, and flexural strength were assessed before and after the grinding procedure to determine the ‘best test group’ in Phase 1. The best abrasive agent was selected for Phase 2 of the study. The specimens in Phase 2 underwent grinding with the best abrasive agent selected. Following the grinding, the specimens were then polished using commercially available diamond polishing paste, a porcelain polishing kit, and an indigenously developed low-temperature sintered zirconia slurry. The physical and mechanical properties were again assessed. Results were analyzed using one-way ANOVA test. Specimens were observed under scanning electron microscopy (SEM) and X-ray diffraction (XRD) for their microstructure and crystalline phases, respectively. Grinding with diamond burs did not weaken zirconia (p > 0.05) but produced rougher surfaces than the control group (p < 0.05). Tungsten carbide burs did not significantly roughen the zirconia surface. However, specimens ground by tungsten carbide burs had a significantly reduced mean flexural strength (p < 0.05) and SEM revealed fine surface cracks. Phase transformation was not detected by XRD. Polishing with commercially available polishing agents, however, restored the surface roughness levels to the control group. Dental monolithic zirconia ground with tungsten carbide burs had a significantly reduced flexural strength and a smooth but defective surface. However, grinding with diamond burs roughened the zirconia surface. These defects may be reduced by polishing with commercially available polishing agents. The use of tungsten carbide burs for grinding dental zirconia should not be advocated. Grinding with diamond abrasives does not weaken zirconia but requires further polishing with commercially available polishing agents.
Open AccessA Comparative Study on Simulated Chairside Grinding and Polishing of Monolithic Zirconia
This study evaluated the effects of different simulated chairside grinding and polishing protocols on the physical and mechanical properties of surface roughness, hardness, and flexural strength of monolithic zirconia. Sintered monolithic zirconia specimens (15 mm × 3 mm × 3 mm) were abraded using three different burs: diamond bur, modified diamond bur (zirconia specified), and tungsten carbide bur, along with a group of unprepared specimens that served as a control group. The study was divided into two phases, Phase 1 and Phase 2. Surface roughness, surface hardness, and flexural strength were assessed before and after the grinding procedure to determine the ‘best test group’ in Phase 1. The best abrasive agent was selected for Phase 2 of the study. The specimens in Phase 2 underwent grinding with the best abrasive agent selected. Following the grinding, the specimens were then polished using commercially available diamond polishing paste, a porcelain polishing kit, and an indigenously developed low-temperature sintered zirconia slurry. The physical and mechanical properties were again assessed. Results were analyzed using one-way ANOVA test. Specimens were observed under scanning electron microscopy (SEM) and X-ray diffraction (XRD) for their microstructure and crystalline phases, respectively. Grinding with diamond burs did not weaken zirconia (p > 0.05) but produced rougher surfaces than the control group (p < 0.05). Tungsten carbide burs did not significantly roughen the zirconia surface. However, specimens ground by tungsten carbide burs had a significantly reduced mean flexural strength (p < 0.05) and SEM revealed fine surface cracks. Phase transformation was not detected by XRD. Polishing with commercially available polishing agents, however, restored the surface roughness levels to the control group. Dental monolithic zirconia ground with tungsten carbide burs had a significantly reduced flexural strength and a smooth but defective surface. However, grinding with diamond burs roughened the zirconia surface. These defects may be reduced by polishing with commercially available polishing agents. The use of tungsten carbide burs for grinding dental zirconia should not be advocated. Grinding with diamond abrasives does not weaken zirconia but requires further polishing with commercially available polishing agents.
- 1 January 2021
- Vol. 14 (2) , 127-138
Comparative evaluation of implant stability quotient trends, crestal bone loss and survival of photofunctionalised and untreated dental implants: A split-mouth randomised controlled clinical trial
Purpose: To evaluate the crestal bone loss and implant stability quotient trends of photofunctionalised versus untreated implants. Materials and methods: A total of 34 patients (age 46.94 +/- 12.03 years) with bilateral single missing teeth in the same arch were enrolled in this study. Each patient received an untreated implant on one side (control group, n = 34) and a photofunctionalised implant on the contralateral side (test group, n = 34). Crestal bone loss was assessed at the time of crown insertion and 1 year later. The osseointegration speed index was evaluated for both the control and test group. An independent t test was used for intergroup comparisons of crestal bone loss and osseointegration speed index. Bivariate analysis was performed for the confounding variables. Results: The test group showed a statistically significantly higher osseointegration speed index (3.07) as compared to the control group (1.29) (P < 0.01). Statistically significantly higher crestal bone loss was observed in the control group (-0.57 +/- 0.41 mm) as compared to the test group (-0.27 +/- 0.35 mm) (P < 0.01). The difference between mean Plaque Index and Bleeding Index in the control (0.74/0.38) and test group (0.73/0.35) was statistically insignificant (P > 0.05). A negative correlation (r = -0.272) was noted between implant diameter and crestal bone loss. A positive correlation (r = 0.402) was observed between implant length and osseointegration speed index. Conclusion: Implants with photofunctionalised surfaces reduce overall healing time and crestal bone loss. Photofunctionalisation is an effective aid for chairside conditioning of implant surfaces to achieve faster osseointegration with good crestal bone stability.
- 1 January 2021
- Vol. 14 (2) , 127-138
Comparative evaluation of implant stability quotient trends, crestal bone loss and survival of photofunctionalised and untreated dental implants: A split-mouth randomised controlled clinical trial
Purpose: To evaluate the crestal bone loss and implant stability quotient trends of photofunctionalised versus untreated implants. Materials and methods: A total of 34 patients (age 46.94 +/- 12.03 years) with bilateral single missing teeth in the same arch were enrolled in this study. Each patient received an untreated implant on one side (control group, n = 34) and a photofunctionalised implant on the contralateral side (test group, n = 34). Crestal bone loss was assessed at the time of crown insertion and 1 year later. The osseointegration speed index was evaluated for both the control and test group. An independent t test was used for intergroup comparisons of crestal bone loss and osseointegration speed index. Bivariate analysis was performed for the confounding variables. Results: The test group showed a statistically significantly higher osseointegration speed index (3.07) as compared to the control group (1.29) (P < 0.01). Statistically significantly higher crestal bone loss was observed in the control group (-0.57 +/- 0.41 mm) as compared to the test group (-0.27 +/- 0.35 mm) (P < 0.01). The difference between mean Plaque Index and Bleeding Index in the control (0.74/0.38) and test group (0.73/0.35) was statistically insignificant (P > 0.05). A negative correlation (r = -0.272) was noted between implant diameter and crestal bone loss. A positive correlation (r = 0.402) was observed between implant length and osseointegration speed index. Conclusion: Implants with photofunctionalised surfaces reduce overall healing time and crestal bone loss. Photofunctionalisation is an effective aid for chairside conditioning of implant surfaces to achieve faster osseointegration with good crestal bone stability.
- 1 January 2021
- Published by Elsevier in Journal of Oral Biology and Craniofacial Research
- Vol. 11 (1) , 40-46
Ultrasound and CBCT analysis of blood flow and dimensions of the lingual vascular canal: A case control study
- 1 January 2021
- Published by Elsevier in Journal of Oral Biology and Craniofacial Research
- Vol. 11 (1) , 40-46
Ultrasound and CBCT analysis of blood flow and dimensions of the lingual vascular canal: A case control study
- 1 October 2020
- Published by Elsevier in Journal of Oral Biology and Craniofacial Research
- Vol. 10 (4) , 705-713
Effect of crown-to-implant ratio on the marginal bone level changes and implant survival – A systematic review and meta-analysis
- 1 October 2020
- Published by Elsevier in Journal of Oral Biology and Craniofacial Research
- Vol. 10 (4) , 705-713
Effect of crown-to-implant ratio on the marginal bone level changes and implant survival – A systematic review and meta-analysis
- 19 June 2020
- Published by Wiley in Clinical Oral Implants Research
- Vol. 31 (9) , 856-864
Prosthetic outcomes and clinical performance of CAD‐CAM monolithic zirconia versus porcelain‐fused‐to‐metal implant crowns in the molar region: 1‐year results of a RCT
Objective: To investigate the clinical performance of monolithic zirconia implant crowns as compared to porcelain‐fused‐to‐metal (PFM) implant crowns.Materials and methods: Seventy‐six healthy patients received reduced diameter implants in the molar region. Following random allocation, either a monolithic zirconia crown (Mono‐ZrO2) or a (PFM) was inserted. Crown and implant survival rates, modified USPHS criteria, clinical measurements, and interproximal marginal bone level (MBL) were assessed at crown delivery (baseline, BL) and at the 1‐year follow‐up (1y‐FU). Data were analyzed descriptively. Fisher's exact test and Wilcoxon rank sum test were applied for statistical analysis. The level of statistical significance was set at p < .05.Results: Thirty‐nine Mono‐ZrO2 and 37 PFM crowns were delivered. At the 1y‐FU, one crown in each group was lost due to loss of the implant. Technical complications occurred in the PFM group and were limited to four minor ceramic chippings resulting in a total technical complication rate of 11.1% (p = .024). Anatomical form and color match compared to the adjacent dentition were rated significantly inferior for the Mono‐ZrO2 crowns. Patient satisfaction was high in both groups at BL (34 Mono‐ZrO2 34 PFM) and at 1y‐FU (36 Mono‐ZrO2 31 PFM). No significant differences between the groups were detected with respect to the change in MBL and to the soft tissue parameters.Conclusions: Monolithic zirconia crowns are a similarly successful alternative option to PFM crowns for restoring single implants in the posterior area.
- 19 June 2020
- Published by Wiley in Clinical Oral Implants Research
- Vol. 31 (9) , 856-864
Prosthetic outcomes and clinical performance of CAD‐CAM monolithic zirconia versus porcelain‐fused‐to‐metal implant crowns in the molar region: 1‐year results of a RCT
Objective: To investigate the clinical performance of monolithic zirconia implant crowns as compared to porcelain‐fused‐to‐metal (PFM) implant crowns.Materials and methods: Seventy‐six healthy patients received reduced diameter implants in the molar region. Following random allocation, either a monolithic zirconia crown (Mono‐ZrO2) or a (PFM) was inserted. Crown and implant survival rates, modified USPHS criteria, clinical measurements, and interproximal marginal bone level (MBL) were assessed at crown delivery (baseline, BL) and at the 1‐year follow‐up (1y‐FU). Data were analyzed descriptively. Fisher's exact test and Wilcoxon rank sum test were applied for statistical analysis. The level of statistical significance was set at p < .05.Results: Thirty‐nine Mono‐ZrO2 and 37 PFM crowns were delivered. At the 1y‐FU, one crown in each group was lost due to loss of the implant. Technical complications occurred in the PFM group and were limited to four minor ceramic chippings resulting in a total technical complication rate of 11.1% (p = .024). Anatomical form and color match compared to the adjacent dentition were rated significantly inferior for the Mono‐ZrO2 crowns. Patient satisfaction was high in both groups at BL (34 Mono‐ZrO2 34 PFM) and at 1y‐FU (36 Mono‐ZrO2 31 PFM). No significant differences between the groups were detected with respect to the change in MBL and to the soft tissue parameters.Conclusions: Monolithic zirconia crowns are a similarly successful alternative option to PFM crowns for restoring single implants in the posterior area.
- Open Access
- 1 January 2020
- Published by Medknow in The Journal of Indian Prosthodontic Society
- Vol. 20 (4) , 371-377
Anatomic variations of the osteomeatal complex and its relationship to patency of the maxillary ostium: A retrospective evaluation of cone-beam computed tomography and its implications for sinus augmentation
Aim: The aim of this study is to determine the incidence of obliterated osteomeatal complex (OMC) due to the presence of anatomic variants. Settings and Design: Retrospective Study. Materials and Methods: In this retrospective study, a total of 71 patients, 34 males and 37 females, aged 35–65 years were included in the study. Cone beam computed tomography (CBCT) scans of patients were assessed to identify the status of the OMC in the presence of anatomic variants and their incidence was recorded. The radiological assessment of the anatomical variants was made by viewing the coronal sections of the scans. The variants observed were deviated nasal septum, uncinate process), agger nasi, Haller cells, middle turbinate variants, enlarged bulla, accessory ostium, and maxillary sinus abnormalities). Ostium patency was evaluated in the coronal section of each sinus and classified as “patent” or “obstructed.” The most common variants observed were then correlated with the patency of the ostium. Statistical Analysis Used: Chi square test was performed to assess the association between the anatomic variants and the patency of the OMC. Results: In the present study, the incidence of an obliterated OMC due to the presence of anatomic variants was 73.2%. The four most common variants associated with the possibility of an obliterated OMC were the deviated nasal septum (76.2%), middle turbinate (86.4%), enlarged bulla (77.8%), and sinus cavity variants (80.0%). A statistically significant association was noted between middle turbinate variants and Haller cells and the patency of the OMC. Conclusion: Thorough pretreatment CBCT evaluation should be performed to assess the presence of anatomic variants and thereby, the patency of the ostium before sinus floor elevation procedures. The pre and postsurgical treatment plans and regimes can be modified according to anticipated postsurgical sequelae, thereby avoiding postsurgical complications and enhancing the success of the graft procedure.
- 1 January 2020
- Published by Medknow in The Journal of Indian Prosthodontic Society
- Vol. 20 (4) , 371-377
Open AccessAnatomic variations of the osteomeatal complex and its relationship to patency of the maxillary ostium: A retrospective evaluation of cone-beam computed tomography and its implications for sinus augmentation
Aim: The aim of this study is to determine the incidence of obliterated osteomeatal complex (OMC) due to the presence of anatomic variants. Settings and Design: Retrospective Study. Materials and Methods: In this retrospective study, a total of 71 patients, 34 males and 37 females, aged 35–65 years were included in the study. Cone beam computed tomography (CBCT) scans of patients were assessed to identify the status of the OMC in the presence of anatomic variants and their incidence was recorded. The radiological assessment of the anatomical variants was made by viewing the coronal sections of the scans. The variants observed were deviated nasal septum, uncinate process), agger nasi, Haller cells, middle turbinate variants, enlarged bulla, accessory ostium, and maxillary sinus abnormalities). Ostium patency was evaluated in the coronal section of each sinus and classified as “patent” or “obstructed.” The most common variants observed were then correlated with the patency of the ostium. Statistical Analysis Used: Chi square test was performed to assess the association between the anatomic variants and the patency of the OMC. Results: In the present study, the incidence of an obliterated OMC due to the presence of anatomic variants was 73.2%. The four most common variants associated with the possibility of an obliterated OMC were the deviated nasal septum (76.2%), middle turbinate (86.4%), enlarged bulla (77.8%), and sinus cavity variants (80.0%). A statistically significant association was noted between middle turbinate variants and Haller cells and the patency of the OMC. Conclusion: Thorough pretreatment CBCT evaluation should be performed to assess the presence of anatomic variants and thereby, the patency of the ostium before sinus floor elevation procedures. The pre and postsurgical treatment plans and regimes can be modified according to anticipated postsurgical sequelae, thereby avoiding postsurgical complications and enhancing the success of the graft procedure.
- 8 October 2018
- Published by Wiley in Clinical Oral Implants Research
- Vol. 29, 114
Does implant site preparation technique affect ISQ trends, bone loss for varying implant lengths?
- 8 October 2018
- Published by Wiley in Clinical Oral Implants Research
- Vol. 29, 114
Does implant site preparation technique affect ISQ trends, bone loss for varying implant lengths?
- 1 April 2018
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 76 (4) , 761-769
Does Graft Particle Type and Size Affect Ridge Dimensional Changes After Alveolar Ridge Split Procedure?
- 1 April 2018
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 76 (4) , 761-769
Does Graft Particle Type and Size Affect Ridge Dimensional Changes After Alveolar Ridge Split Procedure?