TDTom Depuydt

Tom Depuydt

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tom Depuydt has a total of 29 co-authors. Here are the top co-authors by number of shared publications:

  • Karin Haustermans

    Department of Oncology, Laboratory of Experimental Radiotherapy, KU Leuven - University of Leuven, Herestraat 49, B-3000, Leuven, Belgium

    5 shared publications
  • Kenneth Poels

    Department of Radiation Oncology, University Hospitals Leuven, Herestraat 49, B-3000, Leuven, Belgium

    5 shared publications
  • Steven Michiels

    Laboratory of Experimental Radiotherapy, Department of Oncology, KU Leuven - University of Leuven, Belgium

    4 shared publications
  • Wouter Crijns

    Department of Oncology, Laboratory of Experimental Radiotherapy, KU Leuven - University of Leuven, Herestraat 49, B-3000, Leuven, Belgium

    4 shared publications
  • Robin De Roover

    Department of Radiation Oncology, University Hospitals Leuven, Leuven, Belgium

    3 shared publications
  • Sandra Nuyts

    Department of Radiation Oncology, Leuven Cancer Institute University Hospitals Leuven Leuven Belgium

    3 shared publications

Latest Publications

  • Open Access

    Technical Note: Development of 3D‐printed breast phantoms for end‐to‐end testing of whole breast volumetric arc radiotherapy

    by Laurence Delombaerde, Saskia Petillion, Caroline Weltens, Robin De Roover, Truus Reynders, Tom Depuydt

    End‐to‐end testing of a new breast radiotherapy technique preferably requires realistic phantom geometries, which is challenging to achieve using currently commercially available solutions. We have developed a series of three‐dimensional (3D)‐printed breast phantoms, with ionization chamber and radiochromic film inserts, which can be attached to a commercial anthropomorphic thorax phantom. A contoured left breast from a patient’s planning CT was mapped onto a CT of the CIRS E2E thorax phantom (CIRS Inc.) and cropped to fit the surface. Four versions of the breast were 3D printed, containing a cavity for an ionization chamber and slits for radiochromic film insertion in the three cardinal planes, respectively. The phantoms were fully compatible with surface scanning technology used for setup. The phantoms were validated using a whole‐breast volumetric modulated arc therapy protocol with a simultaneous integrated boost to the tumor bed (VMAT‐SIB). Six patient plans and one original plan on the breast phantom were verified with planar portal imaging, point dose, and film measurements in the MultiCube phantom and planar γ‐analysis using ArcCHECK diode array. Six patient plans were recalculated on the breast phantom (hybrid plans) and delivered with point dose and film measurements with 3% (local)/2 mm γ‐analysis. One complete end‐to‐end test on the breast phantom was performed. All plan quality verifications had point dose differences below 2.4% from the calculated dose and γ‐agreement scores (γAS) > 87.3% for film measurements in the MultiCube, portal dosimetry, and ArcCHECK. Point dose differences in the 3D‐printed phantoms were below 2.6% (median −1.4%, range −2.6%; 0.3%). Median γAS was 96.4% (range 80.1%–99.7%) for all film inserts. The proposed 3D‐printed attachable breast dosimetry phantoms have been shown to be a valuable tool for end‐to‐end testing of a new radiotherapy protocol. The workflow described in this report can aid users to create their own phantom‐specific breast 3D‐printed phantoms.


  • Validation and IMRT/VMAT delivery quality of a preconfigured fast‐rotating O‐ring linac system

    by Robin De Roover, Wouter Crijns, Kenneth Poels, Steven Michiels, An Nulens, Bianca Vanstraelen, Saskia Petillion, Marisol De Brabandere, Karin Haustermans, Tom Depuydt

    Purpose: A fast‐rotating O‐ring dedicated intensity modulated radiotherapy (IMRT)/volumetric modulated arc therapy (VMAT) delivery system, the Halcyon, is delivered by default with a fully preconfigured photon beam model in the treatment planning system (TPS). This work reports on the validation and achieved IMRT/VMAT delivery quality on the system.Methods: Acceptance testing followed the vendor's installation product acceptance and was supplemented with mechanical QA. The dosimetric calibration was performed according to the IAEA TRS‐398 code‐of‐practice, delivering 600 cGy/min at 10 cm depth, a 90 cm source‐surface distance, and a 10 × 10 cm² field size. The output factors, multileaf collimator (MLC) transmission and dosimetric leaf gap (DLG) were validated by comparing measurements with the modeled values in the TPS. Validation of IMRT/VMAT was conducted following AAPM reports (MPPG 5.a, TG‐119). Next, dose measurements were performed for end‐to‐end (E2E) checks in heterogeneous anthropomorphic phantoms using radiochromic film in multiple planes and using ionization chambers (IC) point measurements. E2E checks were performed for VMAT (cranial, rectum, spine, and head and neck) and IMRT (lung). Additionally, IROC Houston mailed dosimetry audits were performed for the beam calibration and E2E measurements using a thorax phantom (IMRT) and a head and neck phantom (VMAT). Lastly, extensive patient‐specific QA was performed for the first patients of each new indication, 26 in total (nrectum = 2, nspine = 5, nlung = 5, nesophagus = 2, nhead and neck = 7, ncranial = 5), treated on the fast‐rotating O‐ring linac. The patient‐specific QA followed the AAPM TG‐218 guidelines and comprised of portal dosimetry, ArcCHECK diode array, radiochromic film dosimetry in a MultiCube phantom, and IC point measurements.Results: The measured output factors showed an agreement <1% for fields ≥3 × 3 cm². Field sizes ≤2 × 2 cm² had a difference of 25 cm). TG‐119's confidence limits were achieved for the VMAT point dose measurements and for both the IMRT and VMAT radiochromic film measurements. The TG‐119 confidence limits were not achieved for IMRT point dose measurements in both the target (5.9%) and the avoidance structure (6.4%). All E2E tests had point differences below 2.3% and gamma agreement scores above 90.6%. The IROC beam calibration audit showed agreement of <1%. The IROC lung IMRT audit and head and neck VMAT audit had results compliant with the IROC Houston's credentialing criteria. All IMRT and VMAT plans selected for patient‐specific QA were within the action limits suggested by TG‐218.Conclusions: The fast‐rotating O‐ring linac and its preconfigured TPS are compliant with the international commissioning criteria of AAPM MPPG 5.a and AAPM TG‐119. E2E measurements on heterogeneous anthropomorphic phantoms were within clinically acceptable tolerances. IROC Houston's audits satisfied the credentialing criteria. This work comprises the first extensive dataset reporting on the preconfigured fast‐rotating O‐ring linac.


  • Volumetric modulated arc therapy of head-and-neck cancer on a fast-rotating O-ring linac: Plan quality and delivery time comparison with a C-arm linac

    by Steven Michiels, Kenneth Poels, Wouter Crijns, Laurence Delombaerde, Robin De Roover, Bianca Vanstraelen, Karin Haustermans, Sandra Nuyts, Tom Depuydt


  • Open Access

    Production of patient‐specific electron beam aperture cut‐outs using a low‐cost, multi‐purpose 3D printer

    by Steven Michiels, Bram Mangelschots, Robin De Roover, Cédric Devroye, Tom Depuydt

    Electron beam collimators for non‐standard field sizes and shapes are typically fabricated using Styrofoam molds to cast the aperture cut‐out. These molds are often produced using a dedicated foam cutter, which may be expensive and only serves a single purpose. An increasing number of radiotherapy departments, however, has a 3D printer on‐site, to create a wide range of custom‐made treatment auxiliaries, such as bolus and dosimetry phantoms. The 3D printer can also be used to produce patient‐specific aperture cut‐outs, as elaborated in this note. Open‐source programming language was used to automatically generate the mold's shape in a generic digital file format readable by 3D printer software. The geometric mold model has the patient's identification number integrated and is to be mounted on a uniquely fitting, reusable positioning device, which can be 3D printed as well. This assembly likewise fits uniquely onto the applicator tray, ensuring correct and error‐free alignment of the mold during casting of the aperture. For dosimetric verification, two aperture cut‐outs were cast, one using a conventionally cut Styrofoam mold and one using a 3D printed mold. Using these cut‐outs, the clinical plan was delivered onto a phantom, for which the transversal dose distributions were measured at 2 cm depth using radiochromic film and compared using gamma‐index analysis. An agreement score of 99.9% between the measured 2D dose distributions was found in the (10%–80%) dose region, using 1% (local) dose‐difference and 1.0 mm distance‐to‐agreement acceptance criteria. The workflow using 3D printing has been clinically implemented and is in routine use at the author's institute for all patient‐specific electron beam aperture cut‐outs. It allows for a standardized, cost‐effective, and operator‐friendly workflow without the need for dedicated equipment. In addition, it offers possibilities to increase safety and quality of the process including patient identification and methods for accurate mold alignment.


  • Patient-specific bolus for range shifter air gap reduction in intensity-modulated proton therapy of head-and-neck cancer studied with Monte Carlo based plan optimization

    by Steven Michiels, Ana Maria Barragán, Kevin Souris, Kenneth Poels, Wouter Crijns, John A. Lee, Edmond Sterpin, Sandra Nuyts, Karin Haustermans, Tom Depuydt


  • Open Access

    Proton therapy technology evolution in the clinic: impact on radiation protection

    by T. Depuydt

    The use of proton therapy as a treatment modality is becoming more widespread in conventional radiation therapy practice. Commercialisation and introduction of compact systems has led to embedding of proton therapy facilities in existing hospital environments. In addition, technologically, proton therapy is currently undergoing an important evolution, moving from passive scattering delivery techniques to active pencil beam scanning, adopting image guidance techniques from conventional radiotherapy and introducing various range verification techniques in the clinic. An overview is given of today’s technological evolution of proton therapy in clinical environments, and its impact on aspects of radiation protection.


  • Characterization of a novel liquid fiducial marker for multimodal image guidance in stereotactic body radiotherapy of prostate cancer

    by Robin De Roover, Wouter Crijns, Kenneth Poels, Ronald Peeters, Cédric Draulans, Karin Haustermans, Tom Depuydt

    Purpose: Liquid fiducial markers have shown to be a promising alternative to solid gold markers in terms of imaging artifact reduction, patient comfort, and compatibility with different imaging modalities. This study aims to investigate the performance of the novel BioXmark® liquid marker for state‐of‐the‐art multimodal imaging used in prostate cancer (PCa) radiotherapy, encompassing kV CT/CBCT, multiparametric MRI, and kV x‐ray imaging. In addition, automatic detection of the liquid markers in x‐ray imaging for prostate motion monitoring during treatment was investigated.Methods: A total of eight BioXmark® liquid markers with varying volumes (range 5–300 μL) were casted on a square grid into a gelatin phantom insert. A cylindrical gold marker (QLRAD, length = 7 mm, Ø = 1 mm) was inserted for reference. Liquid marker visibility and streaking artifacts in CT/CBCT imaging were evaluated by placing the gelatin phantom into a CIRS anthropomorphic phantom. Relevant MRI characteristics such as the T2 and T1 relaxation times, the ADC value, and the relative proton density () were quantified by placing the gelatin phantom insert next to a T1MES mapping phantom and a water‐filled syringe for reference. Ex vivo multiparametric MRI images were acquired by placing the gelatin phantom next to a resected prostate specimen. Anterior–posterior x‐ray projection images were obtained by placing the gelatin phantom insert on top of an anthropomorphic pelvic phantom with internal pelvic bony structures and were acquired for five positions relative to the bony anatomy and 24 clinically relevant x‐ray exposure settings. To quantify individual automatic marker detection, single markers were artificially isolated in the x‐ray images using postprocessing.Results: Markers of all sizes were clearly visible on CT and CBCT images with only the largest marker volumes (100–300 μL) displaying artifacts similar in size to the gold fiducial marker. Artifact size increased with increasing liquid marker volume. Liquid markers displayed good contrast in ex vivo T1‐weighted and ‐weighted images. The markers were not visible in the ex vivo T2‐weighted image. The liquid markers induced a chemical shift artifact in the obtained ADC‐map. Automated detection in x‐ray imaging was feasible with high detection success (four of five positions) for marker volumes in the range of 25–200 μL. None of the liquid markers were detected successfully when superimposed on a bony edge, independent of their size.Conclusions: This study is the first to show the compatibility of BioXmark® liquid markers with multimodal image‐guided radiotherapy for PCa. Compared to a solid gold marker, they had favorable results in both visibility and induced imaging artifacts. Liquid marker visibility in MRI imaging of the prostate does not solely depend on the low value (not visible on T2‐weighted image) but is also influenced by its relaxation times. Automated marker detection in x‐ray images was feasible but better adapted marker detection algorithms are necessary for marker localization in the presence of bony edges. Hence, the liquid marker provides a minimally invasive (fine needles) and highly applicable alternative to current solid gold markers for multimodal image‐guided prostate radiotherapy treatments.


  • Towards 3D printed multifunctional immobilization for proton therapy: Initial materials characterization

    by Steven Michiels, Antoine D’hOllander, Nicolas Lammens, Mathias Kersemans, Guozhi Zhang, Jean‐Marc Denis, Kenneth Poels, Edmond Sterpin, Sandra Nuyts, Karin Haustermans, et al.

    Purpose: 3D printing technology is investigated for the purpose of patient immobilization during proton therapy. It potentially enables a merge of patient immobilization, bolus range shifting, and other functions into one single patient‐specific structure. In this first step, a set of 3D printed materials is characterized in detail, in terms of structural and radiological properties, elemental composition, directional dependence, and structural changes induced by radiation damage. These data will serve as inputs for the design of 3D printed immobilization structure prototypes.Methods: Using four different 3D printing techniques, in total eight materials were subjected to testing. Samples with a nominal dimension of 20 × 20 × 80 mm3 were 3D printed. The geometrical printing accuracy of each test sample was measured with a dial gage. To assess the mechanical response of the samples, standardized compression tests were performed to determine the Young's modulus. To investigate the effect of radiation on the mechanical response, the mechanical tests were performed both prior and after the administration of clinically relevant dose levels (70 Gy), multiplied with a safety factor of 1.4. Dual energy computed tomography (DECT) methods were used to calculate the relative electron density to water ρe, the effective atomic number Zeff, and the proton stopping power ratio (SPR) to water SPR. In order to validate the DECT based calculation of radiological properties, beam measurements were performed on the 3D printed samples as well. Photon irradiations were performed to measure the photon linear attenuation coefficients, while proton irradiations were performed to measure the proton range shift of the samples. The directional dependence of these properties was investigated by performing the irradiations for different orientations of the samples.Results: The printed test objects showed reduced geometric printing accuracy for 2 materials (deviation > 0.25 mm). Compression tests yielded Young's moduli ranging from 0.6 to 2940 MPa. No deterioration in the mechanical response was observed after exposure of the samples to 100 Gy in a therapeutic MV photon beam. The DECT‐based characterization yielded Zeff ranging from 5.91 to 10.43. The SPR and ρe both ranged from 0.6 to 1.22. The measured photon attenuation coefficients at clinical energies scaled linearly with ρe. Good agreement was seen between the DECT estimated SPR and the measured range shift, except for the higher Zeff. As opposed to the photon attenuation, the proton range shifting appeared to be printing orientation dependent for certain materials.Conclusions: In this study, the first step toward 3D printed, multifunctional immobilization was performed, by going through a candidate clinical workflow for the first time: from the material printing to DECT characterization with a verification through beam measurements. Besides a proof of concept for beam modification, the mechanical response of printed materials was also investigated to assess their capabilities for positioning functionality. For the studied set of printing techniques and materials, a wide variety of mechanical and radiological properties can be selected from for the intended purpose. Moreover the elaborated hybrid DECT methods aid in performing in‐house quality assurance of 3D printed components, as these methods enable the estimation of the radiological properties relevant for use in radiation therapy.