Benjamin Malard
Research Subjects
Benjamin Malard has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Corine Lambert
MTO Department, Baxter, Meyzieu
1 shared publication- Corine Lambert
R&D Department, Gambro Industries, 7 avenue Lionel Terray, 69330, Meyzieu, France
1 shared publication Dominique Pouchoulin
Research and Development Department, Gambro Industries, Meyzieu, France
1 shared publication- John A. Kellum
Center for Critical Care Nephrology, Department of Critical Care Medicine, University of Pittsburgh, Pittsburgh, USA
1 shared publication Jorge Echeverri
Medical Affairs, Baxter Healthcare Corporation, Deerfield, Illinois
1 shared publicationJulia Koch
Research and Development Department, Gambro Dialysatoren GmbH, Hechingen, Germany
1 shared publication
Latest Publications
- Open Access
- 5 February 2025
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 71 (6) , 510-518
Comparison of Different Membranes for Continuous Renal Replacement Therapies: An In Vitro Study
Inflammatory mediators play a major role in the development and progression of acute kidney injury (AKI). Continuous renal replacement therapy (CRRT) removes these mediators from the blood using AN69-M, AN69-ST, and HF1400 filters to target low and middle-molecular weight molecules. We characterized the in vitro removal performance of each filter in a 72 hour simulated CRRT procedure. Urea clearance with AN69-M and AN69-ST remained stable (52.4 and 51.2 ml/minute, respectively) but decreased with HF1400 (47.0 ml/minute; p < 0.001). Vancomycin clearance remained stable for AN69 filters but decreased for HF1400. Interleukin (IL)-8 was removed primarily via adsorption with the AN69 filters (92.2 and 91.2 ml/minute for AN69-M and AN69-ST, respectively), but clearance was significantly lower with HF1400 (8.4 ml/minute). Tumor necrosis factor (TNF)-α clearance was higher with AN69-ST compared with AN69-M or HF1400 (10.3, 1.8, and 2.3 ml/minute, respectively). β2-microglobulin clearance was higher with both AN69-based filters. The hydrogel water repartition of AN69 filters was different, with a higher percentage of bound water in AN69-ST versus AN69-M (30.5% ± 0.2% and 19.3% ± 1.5%, respectively; p < 0.05). These results suggest that clearance profiles of CRRT filters differ according to their properties; further investigation is needed to translate this into clinical improvements.
- 5 February 2025
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 71 (6) , 510-518
Open AccessComparison of Different Membranes for Continuous Renal Replacement Therapies: An In Vitro Study
Inflammatory mediators play a major role in the development and progression of acute kidney injury (AKI). Continuous renal replacement therapy (CRRT) removes these mediators from the blood using AN69-M, AN69-ST, and HF1400 filters to target low and middle-molecular weight molecules. We characterized the in vitro removal performance of each filter in a 72 hour simulated CRRT procedure. Urea clearance with AN69-M and AN69-ST remained stable (52.4 and 51.2 ml/minute, respectively) but decreased with HF1400 (47.0 ml/minute; p < 0.001). Vancomycin clearance remained stable for AN69 filters but decreased for HF1400. Interleukin (IL)-8 was removed primarily via adsorption with the AN69 filters (92.2 and 91.2 ml/minute for AN69-M and AN69-ST, respectively), but clearance was significantly lower with HF1400 (8.4 ml/minute). Tumor necrosis factor (TNF)-α clearance was higher with AN69-ST compared with AN69-M or HF1400 (10.3, 1.8, and 2.3 ml/minute, respectively). β2-microglobulin clearance was higher with both AN69-based filters. The hydrogel water repartition of AN69 filters was different, with a higher percentage of bound water in AN69-ST versus AN69-M (30.5% ± 0.2% and 19.3% ± 1.5%, respectively; p < 0.05). These results suggest that clearance profiles of CRRT filters differ according to their properties; further investigation is needed to translate this into clinical improvements.
- Top Cited PapersOpen Access
- 4 May 2018
- Published by Springer Nature in Intensive Care Medicine Experimental
- Vol. 6 (1) , 1-13
In vitro comparison of the adsorption of inflammatory mediators by blood purification devices
Septic shock, a leading cause of acute kidney injury, induces release of pro-/anti-inflammatory mediators, leading to increased mortality and poor renal recovery. This is the first in vitro study directly comparing three single-use blood purification devices in terms of removing sepsis-associated mediators and endotoxins. In vitro hemoperfusion was performed using oXiris®, CytoSorb®, and Toraymyxin®. Heparinized human plasma from healthy volunteers was pre-incubated with pathologic quantities of inflammatory mediators and filtered in a closed-loop circulation model for 2 h. For each device, the removal of 27 inflammatory mediators was measured over time. Endotoxin removal mediated by oXiris and Toraymyxin was assessed using hemoperfusion over 6 h. Endotoxin (lipopolysaccharide) removal was most rapid with Toraymyxin; mean adsorptive clearance over the first 30 min was ~ 20 ml/min vs ~ 8 ml/min with oXiris (p < 0.05). There was minimal endotoxin removal with CytoSorb (1 ml/min). At 120 min, there was no significant difference between the endotoxin removal rates using oXiris (mean ± standard deviation, 68.0 ± 4.4%) and Toraymyxin (83.4 ± 3.8%); both were significantly higher vs CytoSorb (− 6.3 ± 4.9%; p < 0.05). Total removal with oXiris was 6.9 μg vs 9.7 μg for Toraymyxin, where the total lipopolysaccharide quantity introduced was approximately 15.8 μg. Removal rates of pro-/anti-inflammatory cytokines and other inflammatory mediators were similar between oXiris and CytoSorb and were higher with CytoSorb and oXiris vs Toraymyxin. Granulocyte colony-stimulating factor was only effectively adsorbed by CytoSorb (99.4%). Differences were detected between the adsorption mechanism of the devices; binding to oXiris was mainly ionic, while CytoSorb was hydrophobic. No specific protein adsorption was found qualitatively with Toraymyxin. Adsorption rate kinetics varied for individual inflammatory mediators using the three blood purification devices. Mechanisms of adsorption differed between the devices. oXiris was the only device tested that showed both endotoxin and cytokine removal. oXiris showed similar endotoxin adsorption to Toraymyxin and similar adsorption to CytoSorb for the removal of other inflammatory mediators. Differences in device removal capacities could enable treatment to be more tailored to patients.
- 4 May 2018
- Published by Springer Nature in Intensive Care Medicine Experimental
- Vol. 6 (1) , 1-13
Top Cited PapersOpen AccessIn vitro comparison of the adsorption of inflammatory mediators by blood purification devices
Septic shock, a leading cause of acute kidney injury, induces release of pro-/anti-inflammatory mediators, leading to increased mortality and poor renal recovery. This is the first in vitro study directly comparing three single-use blood purification devices in terms of removing sepsis-associated mediators and endotoxins. In vitro hemoperfusion was performed using oXiris®, CytoSorb®, and Toraymyxin®. Heparinized human plasma from healthy volunteers was pre-incubated with pathologic quantities of inflammatory mediators and filtered in a closed-loop circulation model for 2 h. For each device, the removal of 27 inflammatory mediators was measured over time. Endotoxin removal mediated by oXiris and Toraymyxin was assessed using hemoperfusion over 6 h. Endotoxin (lipopolysaccharide) removal was most rapid with Toraymyxin; mean adsorptive clearance over the first 30 min was ~ 20 ml/min vs ~ 8 ml/min with oXiris (p < 0.05). There was minimal endotoxin removal with CytoSorb (1 ml/min). At 120 min, there was no significant difference between the endotoxin removal rates using oXiris (mean ± standard deviation, 68.0 ± 4.4%) and Toraymyxin (83.4 ± 3.8%); both were significantly higher vs CytoSorb (− 6.3 ± 4.9%; p < 0.05). Total removal with oXiris was 6.9 μg vs 9.7 μg for Toraymyxin, where the total lipopolysaccharide quantity introduced was approximately 15.8 μg. Removal rates of pro-/anti-inflammatory cytokines and other inflammatory mediators were similar between oXiris and CytoSorb and were higher with CytoSorb and oXiris vs Toraymyxin. Granulocyte colony-stimulating factor was only effectively adsorbed by CytoSorb (99.4%). Differences were detected between the adsorption mechanism of the devices; binding to oXiris was mainly ionic, while CytoSorb was hydrophobic. No specific protein adsorption was found qualitatively with Toraymyxin. Adsorption rate kinetics varied for individual inflammatory mediators using the three blood purification devices. Mechanisms of adsorption differed between the devices. oXiris was the only device tested that showed both endotoxin and cytokine removal. oXiris showed similar endotoxin adsorption to Toraymyxin and similar adsorption to CytoSorb for the removal of other inflammatory mediators. Differences in device removal capacities could enable treatment to be more tailored to patients.
- 2 December 2016
- Published by Wiley in Artificial Organs
- Vol. 41 (6) , 545-555
Adsorption as a Contributor for Inflammatory Mediators Removal by Different Hemofiltration Membranes: A Pilot Study
Atherosclerosis is an important predictor of mortality in patients with chronic kidney disease (CKD) and is associated with a wide inflammatory response. The aim of this study is to evaluate in vitro how different membranes can remove mediators associated with this pathology in a closed loop dialysis model. We performed experimental hemofiltration in vitro using three different membrane materials. Human plasma was preliminarily incubated with various inflammatory mediators and filtered in a closed loop circulation model for 240 min. Respective concentrations of 17 different mediators were measured over time to study the removal mechanisms of each membrane, including associated removal time course. The experiment was repeated three times for the assay of tumor necrosis factor (TNF)‐α to document the model variability. Means were compared using Mann–Whitney test. Most of the investigated mediators were effectively removed with the different dialysis membranes. Adsorption mechanism was mainly at the origin of the decrease in mediators circulating concentrations and was maximized in the region 10 000–20 000 Da. Especially, the HeprAN membrane showed fast removal capacities of mediators with elevated isoelectric point including complement factors and chemokines or having basic groups located in the protein periphery, plasminogen activator inhibitor (PAI‐1), and TNF‐α‐like. The latter was further significantly removed with HeprAN and polymethylmethacrylate (PMMA) compared to polyethersulfone (PES) material (P < 0.01). We concluded that dialysis using ionic adsorptive membrane could have a beneficial impact for CKD patients with atherosclerosis and would deserve further clinical investigations.
- 2 December 2016
- Published by Wiley in Artificial Organs
- Vol. 41 (6) , 545-555
Adsorption as a Contributor for Inflammatory Mediators Removal by Different Hemofiltration Membranes: A Pilot Study
Atherosclerosis is an important predictor of mortality in patients with chronic kidney disease (CKD) and is associated with a wide inflammatory response. The aim of this study is to evaluate in vitro how different membranes can remove mediators associated with this pathology in a closed loop dialysis model. We performed experimental hemofiltration in vitro using three different membrane materials. Human plasma was preliminarily incubated with various inflammatory mediators and filtered in a closed loop circulation model for 240 min. Respective concentrations of 17 different mediators were measured over time to study the removal mechanisms of each membrane, including associated removal time course. The experiment was repeated three times for the assay of tumor necrosis factor (TNF)‐α to document the model variability. Means were compared using Mann–Whitney test. Most of the investigated mediators were effectively removed with the different dialysis membranes. Adsorption mechanism was mainly at the origin of the decrease in mediators circulating concentrations and was maximized in the region 10 000–20 000 Da. Especially, the HeprAN membrane showed fast removal capacities of mediators with elevated isoelectric point including complement factors and chemokines or having basic groups located in the protein periphery, plasminogen activator inhibitor (PAI‐1), and TNF‐α‐like. The latter was further significantly removed with HeprAN and polymethylmethacrylate (PMMA) compared to polyethersulfone (PES) material (P < 0.01). We concluded that dialysis using ionic adsorptive membrane could have a beneficial impact for CKD patients with atherosclerosis and would deserve further clinical investigations.