Mateja Hajduković
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mateja Hajduković has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Mirela Samardžić
Department of Chemistry, Josip Juraj Strossmayer University of Osijek, Cara Hadrijana 8/A, 31000 Osijek, Croatia
2 shared publications - Aleksandar Széchenyi
Department of Chemistry, Josip Juraj Strossmayer University of Osijek, Cara Hadrijana 8/A, 31000 Osijek, Croatia
1 shared publication - Andrea Dandić
Department of Chemistry, Josip Juraj Strossmayer University of Osijek, Cara Hadrijana 8/A, 31000 Osijek, Croatia
1 shared publication - Barna Kovács
Institute of Pharmaceutical Technology and Biopharmacy, Faculty of Pharmacy, University of Pécs, Pécs, Hungary
1 shared publication - Beáta Lemli
Department of Pharmacology, Faculty of Pharmacy, University of Pécs, Rókus u. 2, H-7624 Pécs, Hungary
1 shared publication - Gordana Kralik
Josip Juraj Strossmayer University of Osijek, Faculty of Agriculture in Osijek, HR-31000 Osijek, Croatia
1 shared publication
Latest Publications
- 9 October 2025
- Published by Springer Nature in Journal of Fluorescence
- Vol. 36 (1) , 369-380
A Serinol-Modified 1,8-Naphthalimide Fluorescent Probe for Selective Detection of H₂S in Human Serum and Hypertensive Patients
This research involved the design, preparation, and both structural and fluorescent characterization of a novel fluorescent probe (probe 2) for H2S detection in human blood serum as well as in samples from patients with hypertension. The fluorophore 1,8-naphthalimide was selected, while an azide group served as the chemical reactive site for H2S. To increase the bioavailability of the prepared fluorescent probe, the basic 1,8-naphthalimide scaffold was modified by introducing a 2-aminopropane-1,3-diol (serinol) moiety. Fluorescence spectra were recorded to evaluate the effects of pH, time, selectivity, and H₂S concentration on fluorescence intensity. The detection limit of the target fluorescent probe was found to be 0.16 µmol L−1. Probe 2 was successfully employed for the detection of H₂S in human blood serum, with a measured concentration of 17.98 µmol L⁻¹. The accuracy of H₂S quantification was validated using the standard addition method and confirmed by UV-Vis spectrophotometry employing the methylene blue assay, whereby the concentration was found to be 17.32 µmol L⁻¹. Ultimately, probe 2 was utilized to determine H₂S levels in samples from patients with hypertension, revealing decreased concentrations relative to the concentration observed in a human serum sample as a healthy control.
- 9 October 2025
- Published by Springer Nature in Journal of Fluorescence
- Vol. 36 (1) , 369-380
A Serinol-Modified 1,8-Naphthalimide Fluorescent Probe for Selective Detection of H₂S in Human Serum and Hypertensive Patients
This research involved the design, preparation, and both structural and fluorescent characterization of a novel fluorescent probe (probe 2) for H2S detection in human blood serum as well as in samples from patients with hypertension. The fluorophore 1,8-naphthalimide was selected, while an azide group served as the chemical reactive site for H2S. To increase the bioavailability of the prepared fluorescent probe, the basic 1,8-naphthalimide scaffold was modified by introducing a 2-aminopropane-1,3-diol (serinol) moiety. Fluorescence spectra were recorded to evaluate the effects of pH, time, selectivity, and H₂S concentration on fluorescence intensity. The detection limit of the target fluorescent probe was found to be 0.16 µmol L−1. Probe 2 was successfully employed for the detection of H₂S in human blood serum, with a measured concentration of 17.98 µmol L⁻¹. The accuracy of H₂S quantification was validated using the standard addition method and confirmed by UV-Vis spectrophotometry employing the methylene blue assay, whereby the concentration was found to be 17.32 µmol L⁻¹. Ultimately, probe 2 was utilized to determine H₂S levels in samples from patients with hypertension, revealing decreased concentrations relative to the concentration observed in a human serum sample as a healthy control.
- 13 November 2018
- Published by Wiley in Journal of Surfactants and Detergents
- Vol. 22 (2) , 339-348
Optimization and Applicability of a Novel Sensor for Potentiometric Determination of Anionic Surfactants
Novel potentiometric sensors for anionic surfactant (AS) determination, with different percentages of tetraoctadecylammonium tetraphenylborate (TODA‐TPB) as sensing materials and different electrolytes (sodium chloride, lithium chloride, sodium dodecyl sulfate (NaDS), sodium tetraphenylborate, sodium acetate, and potassium chloride) at varied concentration levels, were developed and compared. The sensor with best response characteristics was further characterized. It had a fast response time (5 s), a low signal drift (2.0 and 2.9 mV h−1 in a detergent solution and NaDS, respectively), a wide pH working range (3–11), and a longer lifetime of 6 months. This novel sensor was characterized with Nernstian response toward NaDS (−58.0 mV decade−1 of activity), a wide working range (1.3 · 10−7–5 · 10−3 M), and a low limit of detection (1.0 · 10−7 M). It proved to be an accurate and reliable sensor for AS determination in multicomponent mixtures of AS and household wastewater using a potentiometric titration method. Nonionic surfactants, which are commonly mixed with AS in commercial products to obtain better properties of products, had an insignificant impact on AS determination.
- 13 November 2018
- Published by Wiley in Journal of Surfactants and Detergents
- Vol. 22 (2) , 339-348
Optimization and Applicability of a Novel Sensor for Potentiometric Determination of Anionic Surfactants
Novel potentiometric sensors for anionic surfactant (AS) determination, with different percentages of tetraoctadecylammonium tetraphenylborate (TODA‐TPB) as sensing materials and different electrolytes (sodium chloride, lithium chloride, sodium dodecyl sulfate (NaDS), sodium tetraphenylborate, sodium acetate, and potassium chloride) at varied concentration levels, were developed and compared. The sensor with best response characteristics was further characterized. It had a fast response time (5 s), a low signal drift (2.0 and 2.9 mV h−1 in a detergent solution and NaDS, respectively), a wide pH working range (3–11), and a longer lifetime of 6 months. This novel sensor was characterized with Nernstian response toward NaDS (−58.0 mV decade−1 of activity), a wide working range (1.3 · 10−7–5 · 10−3 M), and a low limit of detection (1.0 · 10−7 M). It proved to be an accurate and reliable sensor for AS determination in multicomponent mixtures of AS and household wastewater using a potentiometric titration method. Nonionic surfactants, which are commonly mixed with AS in commercial products to obtain better properties of products, had an insignificant impact on AS determination.
- 1 April 2017
- Published by Elsevier in Food Chemistry
- Vol. 221, 1658-1665
Determination of anti-oxidative histidine dipeptides in poultry by microchip capillary electrophoresis with contactless conductivity detection
- 1 April 2017
- Published by Elsevier in Food Chemistry
- Vol. 221, 1658-1665
Determination of anti-oxidative histidine dipeptides in poultry by microchip capillary electrophoresis with contactless conductivity detection