MHMateja Hajduković

Mateja Hajduković

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mateja Hajduković has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Serinol-Modified 1,8-Naphthalimide Fluorescent Probe for Selective Detection of H₂S in Human Serum and Hypertensive Patients

    by Aleksandar Széchenyi, Mateja Budetić, Mirela Samardžić, Maroje Stanković, Ines Drenjančević, Nikolina Kolobarić, Barna Kovács, Beáta Lemli, Gábor Mikle, Andrea Dandić

    This research involved the design, preparation, and both structural and fluorescent characterization of a novel fluorescent probe (probe 2) for H2S detection in human blood serum as well as in samples from patients with hypertension. The fluorophore 1,8-naphthalimide was selected, while an azide group served as the chemical reactive site for H2S. To increase the bioavailability of the prepared fluorescent probe, the basic 1,8-naphthalimide scaffold was modified by introducing a 2-aminopropane-1,3-diol (serinol) moiety. Fluorescence spectra were recorded to evaluate the effects of pH, time, selectivity, and H₂S concentration on fluorescence intensity. The detection limit of the target fluorescent probe was found to be 0.16 µmol L−1. Probe 2 was successfully employed for the detection of H₂S in human blood serum, with a measured concentration of 17.98 µmol L⁻¹. The accuracy of H₂S quantification was validated using the standard addition method and confirmed by UV-Vis spectrophotometry employing the methylene blue assay, whereby the concentration was found to be 17.32 µmol L⁻¹. Ultimately, probe 2 was utilized to determine H₂S levels in samples from patients with hypertension, revealing decreased concentrations relative to the concentration observed in a human serum sample as a healthy control.


  • Optimization and Applicability of a Novel Sensor for Potentiometric Determination of Anionic Surfactants

    by Mirela Samardžić, Sanja Petrušić, Mateja Hajduković, Marija Škobić

    Novel potentiometric sensors for anionic surfactant (AS) determination, with different percentages of tetraoctadecylammonium tetraphenylborate (TODA‐TPB) as sensing materials and different electrolytes (sodium chloride, lithium chloride, sodium dodecyl sulfate (NaDS), sodium tetraphenylborate, sodium acetate, and potassium chloride) at varied concentration levels, were developed and compared. The sensor with best response characteristics was further characterized. It had a fast response time (5 s), a low signal drift (2.0 and 2.9 mV h−1 in a detergent solution and NaDS, respectively), a wide pH working range (3–11), and a longer lifetime of 6 months. This novel sensor was characterized with Nernstian response toward NaDS (−58.0 mV decade−1 of activity), a wide working range (1.3 · 10−7–5 · 10−3 M), and a low limit of detection (1.0 · 10−7 M). It proved to be an accurate and reliable sensor for AS determination in multicomponent mixtures of AS and household wastewater using a potentiometric titration method. Nonionic surfactants, which are commonly mixed with AS in commercial products to obtain better properties of products, had an insignificant impact on AS determination.


  • Determination of anti-oxidative histidine dipeptides in poultry by microchip capillary electrophoresis with contactless conductivity detection

    by Marija Jozanović, Mateja Hajduković, Olivera Galović, Gordana Kralik, Zlata Kralik, Nikola Sakač, Martina Medvidović-Kosanović, Milan Sak-Bosnar