Thomas James Johnston
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Thomas James Johnston has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
Alan Doherty
Department of Urology, Queen Elizabeth Hospital, Birmingham, UK
1 shared publicationAlan Paul
Department of Urology, Leeds Teaching Hospitals NHS Trust, Leeds, UK
1 shared publicationAlastair D. Lamb
Academic Urology Group, University of Cambridge, Cambridge, UK; Cancer Research UK Cambridge Institute, Li Ka Shing Centre, Cambridge, UK
1 shared publicationAlison L. Edwards
Academic Urology Group, University of Cambridge, Cambridge, UK
1 shared publicationAndrew Doble
Department of Urology, Addenbrooke's Hospital, Cambridge, UK
1 shared publicationBen Turney
Oxford University Hospitals, Department of Urology, Oxford, United Kingdom
1 shared publication
Latest Publications
- Open Access
- 1 January 2018
- Published by Polskie Towarzystwo Urologiczne in Central European Journal of Urology
- Vol. 71 (4) , 453-461
A clinical evaluation of the new digital single-use flexible ureteroscope (UscopePU3022): an international prospective multicentered study
Introduction We assessed the clinical performance of a new digital single-use flexible ureteroscope (UscopePU3022). Material and methods A prospective cohort study was carried out across 11 centers (July-Oct. 2017). The UscopePU3022 was assessed regarding ease of insertion; deflection, image quality, maneuverability and overall performance using either a visual analog* or Likert scale. Results A total of 56 procedures were performed in 11 centers (16 surgeons) with the indication being renal stones in 83%. The median score for ease of scope insertion was 10 (3-10). Intraoperative maneuverability was rated as 'good' in 38% and 'very good' in 52%. Visual quality was rated as 'poor or bad' in 18%, 'fair' in 37% and 'good or very good' in 43%. Two scopes failed intraoperatively (4%). Preoperative and postoperative median upward and downward deflection was 270 degrees. Compared to standard flexible ureteroscopy (f-URS) maneuverability was rated as 'equivalent' in 30% and 'better' in 60%; visual quality was 'worse' in 38% and 'equivalent or better' in 62%; limb fatigue scores were 'better' in 86%; and overall performance was 'worse' in 55% and 'equivalent or better' in 45%. Conclusions UscopeTM3022 performed well with regards to maneuverability, deflection and limb fatigue and appears to be at least non-inferior to standard f-URS with regards to these parameters. Poor image quality is a concern for UscopePU3022 with it receiving a low overall performance rating when compared to standard f-URS. Despite this it scored highly when investigators were asked if they would use it in their practice if it was cost-effective to do so.
- 1 January 2018
- Published by Polskie Towarzystwo Urologiczne in Central European Journal of Urology
- Vol. 71 (4) , 453-461
Open AccessA clinical evaluation of the new digital single-use flexible ureteroscope (UscopePU3022): an international prospective multicentered study
Introduction We assessed the clinical performance of a new digital single-use flexible ureteroscope (UscopePU3022). Material and methods A prospective cohort study was carried out across 11 centers (July-Oct. 2017). The UscopePU3022 was assessed regarding ease of insertion; deflection, image quality, maneuverability and overall performance using either a visual analog* or Likert scale. Results A total of 56 procedures were performed in 11 centers (16 surgeons) with the indication being renal stones in 83%. The median score for ease of scope insertion was 10 (3-10). Intraoperative maneuverability was rated as 'good' in 38% and 'very good' in 52%. Visual quality was rated as 'poor or bad' in 18%, 'fair' in 37% and 'good or very good' in 43%. Two scopes failed intraoperatively (4%). Preoperative and postoperative median upward and downward deflection was 270 degrees. Compared to standard flexible ureteroscopy (f-URS) maneuverability was rated as 'equivalent' in 30% and 'better' in 60%; visual quality was 'worse' in 38% and 'equivalent or better' in 62%; limb fatigue scores were 'better' in 86%; and overall performance was 'worse' in 55% and 'equivalent or better' in 45%. Conclusions UscopeTM3022 performed well with regards to maneuverability, deflection and limb fatigue and appears to be at least non-inferior to standard f-URS with regards to these parameters. Poor image quality is a concern for UscopePU3022 with it receiving a low overall performance rating when compared to standard f-URS. Despite this it scored highly when investigators were asked if they would use it in their practice if it was cost-effective to do so.
- Open Access
- 1 March 2017
- Published by Elsevier in European Urology
- Vol. 71 (3) , 381-388
Mortality Among Men with Advanced Prostate Cancer Excluded from the ProtecT Trial
- 1 March 2017
- Published by Elsevier in European Urology
- Vol. 71 (3) , 381-388
Open AccessMortality Among Men with Advanced Prostate Cancer Excluded from the ProtecT Trial
- 30 November 2016
- Published by Springer Nature
- p. 249-255
Lifestyle Advice for Sub-fertile Men
A man with rust coloured urine and normocytic anaemia
A 65 year old man presented to the emergency department with a 10 day history of dark urine, general malaise, and progressive shortness of breath. He had a history of rheumatic heart disease and had been on warfarin since he had a metallic mitral valve replacement in 1984. He was a retired teacher, drank a minimal amount of alcohol, and was a non-smoker. He had no family history of cancer. On examination he was jaundiced with a sinus tachycardia (120 beats/min) and a pansystolic murmur. His other vital signs were normal. On examination, his other systems were normal except for mild suprapubic tenderness, as were the results of a digital rectal examination. His urine was rust coloured (fig 1⇓) with no blood clots. Urine dipstick was positive for blood (3+), protein (3+), and leucocytes (3+), but negative for nitrites. No red blood cells or casts were noted during microscopy. Fig 1 Patient’s urine on admission The table⇓ shows the results of his initial laboratory investigations. A peripheral blood film showed red cell fragments, polychromasia, and normal platelets (a representative smear is shown in fig 2⇓). The results of chest radiography, computed tomography of the kidneys, and ultrasound of the urinary tract were also unremarkable. Serial sepsis screens and three sets of blood cultures for endocarditis were all negative. View this table: Laboratory test results on admission Fig 2 A representative blood film showing red cell fragments (arrows) ### 1. What are the causes of dark urine? #### Answer Haematuria, menstrual contamination, haemoglobinuria, and myoglobinuria will cause dark urine that is positive for blood on urine dipstick testing. Red cells …
A man with rust coloured urine and normocytic anaemia
A 65 year old man presented to the emergency department with a 10 day history of dark urine, general malaise, and progressive shortness of breath. He had a history of rheumatic heart disease and had been on warfarin since he had a metallic mitral valve replacement in 1984. He was a retired teacher, drank a minimal amount of alcohol, and was a non-smoker. He had no family history of cancer. On examination he was jaundiced with a sinus tachycardia (120 beats/min) and a pansystolic murmur. His other vital signs were normal. On examination, his other systems were normal except for mild suprapubic tenderness, as were the results of a digital rectal examination. His urine was rust coloured (fig 1⇓) with no blood clots. Urine dipstick was positive for blood (3+), protein (3+), and leucocytes (3+), but negative for nitrites. No red blood cells or casts were noted during microscopy. Fig 1 Patient’s urine on admission The table⇓ shows the results of his initial laboratory investigations. A peripheral blood film showed red cell fragments, polychromasia, and normal platelets (a representative smear is shown in fig 2⇓). The results of chest radiography, computed tomography of the kidneys, and ultrasound of the urinary tract were also unremarkable. Serial sepsis screens and three sets of blood cultures for endocarditis were all negative. View this table: Laboratory test results on admission Fig 2 A representative blood film showing red cell fragments (arrows) ### 1. What are the causes of dark urine? #### Answer Haematuria, menstrual contamination, haemoglobinuria, and myoglobinuria will cause dark urine that is positive for blood on urine dipstick testing. Red cells …