Takaaki Oda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Takaaki Oda has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Ichiro Ogura
Department of Oral and Maxillofacial Radiology, The Nippon Dental University School of Life Dentistry at Niigata, Niigata, Japan
4 shared publications Mikiko Sue
The Nippon Dental University Niigata Hospital
3 shared publicationsYoshihiko Sasaki
The Nippon Dental University Niigata Hospital
3 shared publicationsYasuo Okada
Department of Pathology, The Nippon Dental University School of Life Dentistry at Niigata, Niigata, Japan
2 shared publicationsAyako Kameta
Department of Oral and Maxillofacial Radiology The Nippon Dental University School of Life Dentistry at Niigata Niigata Japan
1 shared publicationJunya Ono
Department of Pathology, The Nippon Dental University School of Life Dentistry at Niigata, Niigata, Japan
1 shared publication
Latest Publications
- 4 September 2017
- Published by Springer Nature in Oral Radiology
- Vol. 34 (3) , 224-228
Diffusion-weighted magnetic resonance imaging in oral and maxillofacial lesions: preliminary study on diagnostic ability of apparent diffusion coefficient maps
The aim of this study was to investigate the usefulness of diffusion-weighted magnetic resonance imaging (DWI) in oral and maxillofacial lesions, especially the utility of apparent diffusion coefficient (ADC) maps for differential diagnosis of these lesions.
- 4 September 2017
- Published by Springer Nature in Oral Radiology
- Vol. 34 (3) , 224-228
Diffusion-weighted magnetic resonance imaging in oral and maxillofacial lesions: preliminary study on diagnostic ability of apparent diffusion coefficient maps
The aim of this study was to investigate the usefulness of diffusion-weighted magnetic resonance imaging (DWI) in oral and maxillofacial lesions, especially the utility of apparent diffusion coefficient (ADC) maps for differential diagnosis of these lesions.
- 29 August 2017
- Published by Sciedu Press in International Journal of Diagnostic Imaging
- Vol. 5 (1) , 20
Changes of cerebrospinal fluid in the upper neck area with age using diffusion weighted MR imaging
Purpose: Few studies have concerned the absolute apparent diffusion coefficient (ADC) values in the normal cerebrospinal fluid in the upper neck area and the effect of aging on diffusion. The purpose of this study was to evaluate changes of cerebrospinal fluid in the upper neck area with age using diffusion weighted MR imaging (DWI).Methods and methods: Our study included 160 patients who underwent MR imaging for oral and maxillofacial diseases. All patients were examined by DWI with 2 b values (0 and 800 sec/mm2) at 1.5 Tesla and ADC maps. The cerebrospinal fluid and spinal cord in the upper neck area were analyzed using the ADC values and age.Results: ADC value of cerebrospinal fluid was significantly correlated to ADC value of spinal cord (R2 = 0.141, p = .000). ADC value of spinal cord had no relation to age (R2 = 0.015, p = .125). ADC value of cerebrospinal fluid had significant relation to age (R2= 0.026, p = .042).Conclusions: We indicated the changes of cerebrospinal fluid in the upper neck area with age using DWI. The data reported herein are representative, and the ADC values can be used for reference in future studies and in clinical settings.
- 29 August 2017
- Published by Sciedu Press in International Journal of Diagnostic Imaging
- Vol. 5 (1) , 20
Changes of cerebrospinal fluid in the upper neck area with age using diffusion weighted MR imaging
Purpose: Few studies have concerned the absolute apparent diffusion coefficient (ADC) values in the normal cerebrospinal fluid in the upper neck area and the effect of aging on diffusion. The purpose of this study was to evaluate changes of cerebrospinal fluid in the upper neck area with age using diffusion weighted MR imaging (DWI).Methods and methods: Our study included 160 patients who underwent MR imaging for oral and maxillofacial diseases. All patients were examined by DWI with 2 b values (0 and 800 sec/mm2) at 1.5 Tesla and ADC maps. The cerebrospinal fluid and spinal cord in the upper neck area were analyzed using the ADC values and age.Results: ADC value of cerebrospinal fluid was significantly correlated to ADC value of spinal cord (R2 = 0.141, p = .000). ADC value of spinal cord had no relation to age (R2 = 0.015, p = .125). ADC value of cerebrospinal fluid had significant relation to age (R2= 0.026, p = .042).Conclusions: We indicated the changes of cerebrospinal fluid in the upper neck area with age using DWI. The data reported herein are representative, and the ADC values can be used for reference in future studies and in clinical settings.
- Open Access
- 1 January 2017
- Published by XMLink in Imaging Science in Dentistry
- Vol. 47 (3) , 209-213
Central giant cell lesion of the mandible in a 2-year old girl
Oda T, et al. Imaging Sci Dent. 2017 Sep;47(3):209-213. https://doi.org/10.5624/isd.2017.47.3.209
- 1 January 2017
- Published by XMLink in Imaging Science in Dentistry
- Vol. 47 (3) , 209-213
Open AccessCentral giant cell lesion of the mandible in a 2-year old girl
Oda T, et al. Imaging Sci Dent. 2017 Sep;47(3):209-213. https://doi.org/10.5624/isd.2017.47.3.209
- Open Access
- 20 September 2016
- Published by Wiley in Oral Science International
- Vol. 14 (1) , 18-21
Extraosseous plasmacytoma of the Maxilla: CT and MRI findings
Plasmacytomas are a localized proliferation of plasma cells in the bone marrow and are less frequently seen in extraosseous organs or tissues. Extraosseous plasmacytoma is a rare malignant neoplasm and constitutes 3–5% of all plasma cell neoplasms. In this article, we describe a case of a patient with extraosseous plasmacytoma of the maxilla and the related computed tomography (CT) and magnetic resonance imaging (MRI) findings.
- 20 September 2016
- Published by Wiley in Oral Science International
- Vol. 14 (1) , 18-21
Open AccessExtraosseous plasmacytoma of the Maxilla: CT and MRI findings
Plasmacytomas are a localized proliferation of plasma cells in the bone marrow and are less frequently seen in extraosseous organs or tissues. Extraosseous plasmacytoma is a rare malignant neoplasm and constitutes 3–5% of all plasma cell neoplasms. In this article, we describe a case of a patient with extraosseous plasmacytoma of the maxilla and the related computed tomography (CT) and magnetic resonance imaging (MRI) findings.
- 1 March 2009
- Vol. 46 (1) , 1-12
[Evaluation of small semiconductor gamma camera--simulation of sentinel lymph node biopsy by using a trial product of clinical type gamma camera].
This study was to verify the performance of three different collimators that were equipped to the clinical application type of small semiconductor gamma camera (SSGC) for radio-guided surgery. We also wanted to see if the clinical application type could be effective to detect sentinel nodes in simulation studies for sentinel lymph node biopsy. The camera head consisted of a pixelized CdTe module (32 x 32 individual elements, total of 1,024 pixels) (Acrorad Co. Ltd., Tokyo, Japan). The field of view was 44.8 mm x 44.8 mm. The clinical application type of this gamma camera had three exchangeable collimators; standard, high sensitivity and high resolution (ST, HS, HR). Energy resolution, full-width at half-maximum (FWHM), of the CdTe detector attached with the standard collimator was 6.9% at 141 keV (99mTc). The spatial resolution, represented by FWHM, had a mean value of 1.59 mm. The data was comparable to the results of the prototype SSGC. The simulation studies showed that HS could more sensitively detect the simulated nodes than ST and HR did, and HR could more reliably distinguish the simulated sentinel node that situated close to the injection site than other two collimators did. However the depiction was interfered by the higher background radiation levels. We suggest that this SSGC clinical application type may provide advantages over the standard system for isolating sentinel lymph nodes biopsy. We also believe that the SSGC may aid surgeons in identifying target tissues when performing radio-guided surgery.
- 1 March 2009
- Vol. 46 (1) , 1-12
[Evaluation of small semiconductor gamma camera--simulation of sentinel lymph node biopsy by using a trial product of clinical type gamma camera].
This study was to verify the performance of three different collimators that were equipped to the clinical application type of small semiconductor gamma camera (SSGC) for radio-guided surgery. We also wanted to see if the clinical application type could be effective to detect sentinel nodes in simulation studies for sentinel lymph node biopsy. The camera head consisted of a pixelized CdTe module (32 x 32 individual elements, total of 1,024 pixels) (Acrorad Co. Ltd., Tokyo, Japan). The field of view was 44.8 mm x 44.8 mm. The clinical application type of this gamma camera had three exchangeable collimators; standard, high sensitivity and high resolution (ST, HS, HR). Energy resolution, full-width at half-maximum (FWHM), of the CdTe detector attached with the standard collimator was 6.9% at 141 keV (99mTc). The spatial resolution, represented by FWHM, had a mean value of 1.59 mm. The data was comparable to the results of the prototype SSGC. The simulation studies showed that HS could more sensitively detect the simulated nodes than ST and HR did, and HR could more reliably distinguish the simulated sentinel node that situated close to the injection site than other two collimators did. However the depiction was interfered by the higher background radiation levels. We suggest that this SSGC clinical application type may provide advantages over the standard system for isolating sentinel lymph nodes biopsy. We also believe that the SSGC may aid surgeons in identifying target tissues when performing radio-guided surgery.