P. Percival
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
P. Percival has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
U. Proske
3 shared publications- David L. Morgan
Department of Electrical and Computer Systems Engineering, Monash University, Clayton, Victoria 3800, Australia
2 shared publications B. J. Canny
1 shared publicationD. Morgan
1 shared publicationJ. E. Gregory
Monash University
1 shared publicationJ. Richardson
1 shared publication
Latest Publications
- 1 December 2005
- Published by Elsevier in Journal of Science and Medicine in Sport
- Vol. 8, 96
170 Isokinetic torque-angle testing and eccentric training as a strategy to prevent hamstring injury in AFL football players
- 1 December 2005
- Published by Elsevier in Journal of Science and Medicine in Sport
- Vol. 8, 96
170 Isokinetic torque-angle testing and eccentric training as a strategy to prevent hamstring injury in AFL football players
- 25 January 2003
- Published by Springer Nature in Experimental Brain Research
- Vol. 149 (2) , 141-150
Matching different levels of isometric torque in elbow flexor muscles after eccentric exercise
Human subjects generated a specified level of isometric torque with elbow flexor muscles of one arm, the reference arm, under visual feedback. They were then asked to generate what they perceived to be the same level, with the other arm, the indicator, but with no visual feedback. A number of torque levels, between 2% and 30% of maximum were used in the matching trials. Elbow flexors of one arm were then exercised eccentrically on a dynamometer. Immediately after the exercise, there was a large (40%) drop in maximum voluntary torque, as well as some soreness and swelling 24 h later, indicative of muscle damage. When the torque-matching experiment was repeated after the indicator arm had been exercised, the indicator signalled torque levels significantly below the reference level (P<0.05). When the reference arm was exercised, errors were in the opposite direction. Over the 4 days of testing post-exercise, errors became less as torque levels returned to normal. When errors were expressed in terms of maximum torque post-exercise, they were significantly reduced. This suggested that subjects were using as a matching cue the perceived effort required to generate a given level of torque rather than the level of torque itself. Persisting matching errors, from 24 h onwards after the eccentric contractions, were proposed to include a component attributable to the muscle soreness. Changes in electromyogram recorded after eccentric exercise were consistent with the effort-matching hypothesis. The muscle's torque–angle relationship was used to estimate matching ability in the absence of fatigue. One forearm was placed at various angles and its reference torque was matched by the other, the indicator, always at 90°. Again, matching errors were consistent with an interpretation based on a match of effort rather than torque.
- 25 January 2003
- Published by Springer Nature in Experimental Brain Research
- Vol. 149 (2) , 141-150
Matching different levels of isometric torque in elbow flexor muscles after eccentric exercise
Human subjects generated a specified level of isometric torque with elbow flexor muscles of one arm, the reference arm, under visual feedback. They were then asked to generate what they perceived to be the same level, with the other arm, the indicator, but with no visual feedback. A number of torque levels, between 2% and 30% of maximum were used in the matching trials. Elbow flexors of one arm were then exercised eccentrically on a dynamometer. Immediately after the exercise, there was a large (40%) drop in maximum voluntary torque, as well as some soreness and swelling 24 h later, indicative of muscle damage. When the torque-matching experiment was repeated after the indicator arm had been exercised, the indicator signalled torque levels significantly below the reference level (P<0.05). When the reference arm was exercised, errors were in the opposite direction. Over the 4 days of testing post-exercise, errors became less as torque levels returned to normal. When errors were expressed in terms of maximum torque post-exercise, they were significantly reduced. This suggested that subjects were using as a matching cue the perceived effort required to generate a given level of torque rather than the level of torque itself. Persisting matching errors, from 24 h onwards after the eccentric contractions, were proposed to include a component attributable to the muscle soreness. Changes in electromyogram recorded after eccentric exercise were consistent with the effort-matching hypothesis. The muscle's torque–angle relationship was used to estimate matching ability in the absence of fatigue. One forearm was placed at various angles and its reference torque was matched by the other, the indicator, always at 90°. Again, matching errors were consistent with an interpretation based on a match of effort rather than torque.
- 1 January 2003
- Published by Taylor & Francis in Somatosensory & Motor Research
- Vol. 20 (1) , 27-32
Force matching at the elbow joint is disturbed by muscle soreness
These experiments are concerned with the ability of human subjects to match isometric torque in their elbow flexor muscles when biceps of one arm is made sore. Pain was induced by injection of hypertonic saline. Subjects were asked to generate a level of torque, 30% of maximum, with one arm, the reference arm. To achieve the required torque, subjects were given visual feedback. Subjects were then asked to match this torque with their other arm, the indicator arm. In control measurements, subjects were consistent in their matching ability and often were quite accurate. However, when biceps of one arm was made sore, subjects consistently and significantly underestimated the level of torque being generated by the sore arm. Painful heat applied to the skin over biceps produced a similar pattern of errors. Heating skin remote from elbow flexors had no significant effect. One interpretation of these findings is that the nociceptive input from the sore region of skin or muscle leads to reduced excitability of the motor cortex. That, in turn, disturbs the relationship between the centrally generated effort and motor output, leading to matching errors.
- 1 January 2003
- Published by Taylor & Francis in Somatosensory & Motor Research
- Vol. 20 (1) , 27-32
Force matching at the elbow joint is disturbed by muscle soreness
These experiments are concerned with the ability of human subjects to match isometric torque in their elbow flexor muscles when biceps of one arm is made sore. Pain was induced by injection of hypertonic saline. Subjects were asked to generate a level of torque, 30% of maximum, with one arm, the reference arm. To achieve the required torque, subjects were given visual feedback. Subjects were then asked to match this torque with their other arm, the indicator arm. In control measurements, subjects were consistent in their matching ability and often were quite accurate. However, when biceps of one arm was made sore, subjects consistently and significantly underestimated the level of torque being generated by the sore arm. Painful heat applied to the skin over biceps produced a similar pattern of errors. Heating skin remote from elbow flexors had no significant effect. One interpretation of these findings is that the nociceptive input from the sore region of skin or muscle leads to reduced excitability of the motor cortex. That, in turn, disturbs the relationship between the centrally generated effort and motor output, leading to matching errors.