Nagaranjan Gnanasekaran
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Nagaranjan Gnanasekaran has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Banjara Kotresha
Government Engineering College
8 shared publications - Moghtada Mobedi
Mechanical Engineering Department, Faculty of Engineering, Shizuoka University, 3-5-1 Johoku, Naka-ku, Hamamatsu-shi 432-8561, Japan
4 shared publications Banjara Kotresha
Department of Mechanical Engineering, Government Engineering College, Haveri, India
2 shared publications- Dharmarajan Arumuga Perumal
Department of Mechanical Engineering, National Institute of Technology Karnataka, Surathkal, Mangalore, India
2 shared publications G. Narendran
National Institute of Technology Karnataka, Surathkal Department of Mechanical Engineering Mangalore 575025, Karnataka , India
2 shared publicationsHarsha Kumar
Department of Mechanical Engineering, National Institute of Technology, Surathkal, India
2 shared publications
Latest Publications
- 2 February 2024
- Published by Springer Nature
- p. 841-855
Effect of Geometric Parameters on Steady-State Supersonic Film Cooling of the Basic Conical Rocket Nozzle
- 2 February 2024
- Published by Springer Nature
- p. 841-855
Effect of Geometric Parameters on Steady-State Supersonic Film Cooling of the Basic Conical Rocket Nozzle
- 7 January 2024
- Published by Springer Nature
- p. 471-482
Flow and Heat Transfer Phenomena Through Porous Media Under Turbulent Regime
- 7 January 2024
- Published by Springer Nature
- p. 471-482
Flow and Heat Transfer Phenomena Through Porous Media Under Turbulent Regime
- Open Access
- 1 January 2024
- Published by Academic World Research in Journal of Applied Fluid Mechanics
- Vol. 17 (3) , 548-558
3D Numerical Modelling of Turbulent Flow in a Channel Partially Filled with Different Blockage Ratios of Metal Foam
The aim of the present research work is to understand the intricacies of fluid flow through a rectangular channel that has been partially filled with a metal foam block of different blockage ratio (0.16-1), with a pore density (5–30 Pores Per Inch i.e. PPI), along with varying inlet velocity (6.5–12.5 m/s). For the porous region, numerical solutions are acquired using the Darcy Extended Forchheimer model. The Navier-Stokes equation is used in the non-porous zone. Different flow behaviours were seen as a function of PPI, height, and inlet velocity. The pressure drop increases with inlet velocity, PPI, and block height, with a maximum value of approximately 4.5 kPa for the case of 30 PPI, 12.5 m/s, and a blockage ratio of 1. Results show that the existence and location of the formation of eddies depends on the inlet velocity, PPI, and blockage ratio. Such studies have been reported less and will aid research on forced convection through a channel partially filled with metal foam and optimisation studies between increased heat transmission and the additional pressure drop for the same by providing a detailed fluid flow analysis.
- 1 January 2024
- Published by Academic World Research in Journal of Applied Fluid Mechanics
- Vol. 17 (3) , 548-558
Open Access3D Numerical Modelling of Turbulent Flow in a Channel Partially Filled with Different Blockage Ratios of Metal Foam
The aim of the present research work is to understand the intricacies of fluid flow through a rectangular channel that has been partially filled with a metal foam block of different blockage ratio (0.16-1), with a pore density (5–30 Pores Per Inch i.e. PPI), along with varying inlet velocity (6.5–12.5 m/s). For the porous region, numerical solutions are acquired using the Darcy Extended Forchheimer model. The Navier-Stokes equation is used in the non-porous zone. Different flow behaviours were seen as a function of PPI, height, and inlet velocity. The pressure drop increases with inlet velocity, PPI, and block height, with a maximum value of approximately 4.5 kPa for the case of 30 PPI, 12.5 m/s, and a blockage ratio of 1. Results show that the existence and location of the formation of eddies depends on the inlet velocity, PPI, and blockage ratio. Such studies have been reported less and will aid research on forced convection through a channel partially filled with metal foam and optimisation studies between increased heat transmission and the additional pressure drop for the same by providing a detailed fluid flow analysis.
- 16 December 2023
- Published by Springer Nature
- p. 17-29
Performance Evaluation of Single Pass Solar Air Heater with Stepped-Type Arrangement of Metal Foam by a Numerical Study
- 16 December 2023
- Published by Springer Nature
- p. 17-29
Performance Evaluation of Single Pass Solar Air Heater with Stepped-Type Arrangement of Metal Foam by a Numerical Study
- 18 November 2023
- Published by Springer Nature
- p. 665-675
Estimation of Breast Tumor Parameters by Random Forest Method with the Help of Temperature Data on the Surface of the Numerical Breast Model
- 18 November 2023
- Published by Springer Nature
- p. 665-675
Estimation of Breast Tumor Parameters by Random Forest Method with the Help of Temperature Data on the Surface of the Numerical Breast Model
- Open Access
Thermohydraulic Efficiency of a Solar Air Heater in the Presence of Graded Aluminium Wire Mesh—A Combined Experimental–Numerical Study
In this work, aluminium wire mesh (WM) samples with 3, 9, and 18 pores per inch (PPI) and porosities of 0.894, 0.812, and 0.917, respectively, were combined together to form graded structures including 3-9-18, 9-18-3, and 18-3-9 PPIs. A 5 mm thickness for each WM was considered for a length of 2 m and inserted into a single-pass solar air heater (SAH) in which the height of the SAH was 120 mm. For the numerical analysis, a 3D numerical model was considered in ANSYS fluent software, and the Rosseland radiation model renormalization group (RNG) k-ε enhanced wall function was incorporated to account for solar radiation. The local thermal equilibrium (LTE) model was considered to obtain the heat-transfer characteristics of the WM. The numerical results of the thermohydraulic performance parameter (THPP) of the 9-18-3 PPI WM were 13.04% and 11.92% higher than the 3-9-18 and 18-3-9 PPI samples, respectively. Later, 25% of the 9-18-3 graded wire mesh (GWM) was considered at four different locations, i.e., 0, 0.5, 1, and 1.5 m away from the inlet, and analysed to obtain the best location for efficient heat transfer. The computational results show that 1.5 m away from the inlet is the best location among the different locations considered. The experimental results of the GWM at 1.5 m away from the inlet demonstrated a 20.91% and 23.32% increase in thermal efficiency compared to the empty channel for the 0.027 kg/s and 0.058 kg/s mass flow rates, respectively. From numerical-cum-experimental analysis, it was found that inserting 25% length of GWM of the entire length of the test section at a distance of 1.5 m from the inlet in single pass SAH improves the overall performance of the empty channel of single-pass SAH.
Open AccessThermohydraulic Efficiency of a Solar Air Heater in the Presence of Graded Aluminium Wire Mesh—A Combined Experimental–Numerical Study
In this work, aluminium wire mesh (WM) samples with 3, 9, and 18 pores per inch (PPI) and porosities of 0.894, 0.812, and 0.917, respectively, were combined together to form graded structures including 3-9-18, 9-18-3, and 18-3-9 PPIs. A 5 mm thickness for each WM was considered for a length of 2 m and inserted into a single-pass solar air heater (SAH) in which the height of the SAH was 120 mm. For the numerical analysis, a 3D numerical model was considered in ANSYS fluent software, and the Rosseland radiation model renormalization group (RNG) k-ε enhanced wall function was incorporated to account for solar radiation. The local thermal equilibrium (LTE) model was considered to obtain the heat-transfer characteristics of the WM. The numerical results of the thermohydraulic performance parameter (THPP) of the 9-18-3 PPI WM were 13.04% and 11.92% higher than the 3-9-18 and 18-3-9 PPI samples, respectively. Later, 25% of the 9-18-3 graded wire mesh (GWM) was considered at four different locations, i.e., 0, 0.5, 1, and 1.5 m away from the inlet, and analysed to obtain the best location for efficient heat transfer. The computational results show that 1.5 m away from the inlet is the best location among the different locations considered. The experimental results of the GWM at 1.5 m away from the inlet demonstrated a 20.91% and 23.32% increase in thermal efficiency compared to the empty channel for the 0.027 kg/s and 0.058 kg/s mass flow rates, respectively. From numerical-cum-experimental analysis, it was found that inserting 25% length of GWM of the entire length of the test section at a distance of 1.5 m from the inlet in single pass SAH improves the overall performance of the empty channel of single-pass SAH.
- 6 January 2023
- Published by Springer Nature in Heat and Mass Transfer
- Vol. 59 (7) , 1311-1332
Experimental investigation on additive manufactured single and curved double layered microchannel heat sink with nanofluids
- 6 January 2023
- Published by Springer Nature in Heat and Mass Transfer
- Vol. 59 (7) , 1311-1332
Experimental investigation on additive manufactured single and curved double layered microchannel heat sink with nanofluids
- Open Access
Numerical Study for Enhancement of Heat Transfer Using Discrete Metal Foam with Varying Thickness and Porosity in Solar Air Heater by LTNE Method
A two-dimensional rectangular domain is considered with a discrete arrangement at equal distances from copper metal foam in a solar air heater (SAH). The local thermal non-equilibrium model is used for the analysis of heat transfer in a single-pass rectangular channel of SAH for different mass flow rates ranging from 0.03 to 0.05 kg/s at 850 W/m2 heat flux. Three different pores per inch (PPI) and porosities of copper metal foam with three different discrete thicknesses at equal distances are studied numerically. This paper evaluates the performance of SAH with 10 PPI 0.8769 porosity, 20 PPI 0.8567 porosity, and 30 PPI 0.92 porosity at 22 mm, 44 mm, and 88 mm thicknesses. The Nusselt number for 22 mm, 44 mm, and 88 mm thicknesses is 157.64%, 183.31%, and 218.60%, respectively, higher than the empty channel. The performance factor for 22 mm thick metal foam is 5.02% and 16.61% higher than for 44 mm and 88 mm thick metal foam, respectively. Hence, it is found that metal foam can be an excellent option for heat transfer enhancement in SAH, if it is designed properly.
Open AccessNumerical Study for Enhancement of Heat Transfer Using Discrete Metal Foam with Varying Thickness and Porosity in Solar Air Heater by LTNE Method
A two-dimensional rectangular domain is considered with a discrete arrangement at equal distances from copper metal foam in a solar air heater (SAH). The local thermal non-equilibrium model is used for the analysis of heat transfer in a single-pass rectangular channel of SAH for different mass flow rates ranging from 0.03 to 0.05 kg/s at 850 W/m2 heat flux. Three different pores per inch (PPI) and porosities of copper metal foam with three different discrete thicknesses at equal distances are studied numerically. This paper evaluates the performance of SAH with 10 PPI 0.8769 porosity, 20 PPI 0.8567 porosity, and 30 PPI 0.92 porosity at 22 mm, 44 mm, and 88 mm thicknesses. The Nusselt number for 22 mm, 44 mm, and 88 mm thicknesses is 157.64%, 183.31%, and 218.60%, respectively, higher than the empty channel. The performance factor for 22 mm thick metal foam is 5.02% and 16.61% higher than for 44 mm and 88 mm thick metal foam, respectively. Hence, it is found that metal foam can be an excellent option for heat transfer enhancement in SAH, if it is designed properly.
- 25 October 2022
- Published by Taylor & Francis in Heat Transfer Engineering
- Vol. 44 (15) , 1433-1451
Inverse Estimation of Breast Tumor Size and Location with Numerical Thermal Images of Breast Model Using Machine Learning Models
Early screening of cancer plays a vital role in successful treatment. Normally, the temperature of breast surface changes due to the size and location of the underlying tumor. Temperature patterns can be used to estimate the size and location of tumor by an inverse approach using machine learning algorithms. The present study aims to provide an efficient machine learning model that can be relied on to predict the size and location of the tumor using numerical thermal images. There is no availability of actual thermal images labeled with the size and location of the tumor. Consequently, successive numerical simulations are used to develop the numerical thermal image dataset with a three-dimensional breast model solved with COMSOL Multiphysics. The obtained numerical thermal images are uniquely labeled with the corresponding size and location of the tumor and trained using various machine learning regression models such as linear, support vector, K-nearest neighbor, and decision tree regression models. The results are analyzed using parity plots and mean absolute error. The present study found that the decision tree regression model outperformed the other machine learning models and improved the estimation accuracy by rejecting the numerical thermal images which are having slight variation in surface temperature.
- 25 October 2022
- Published by Taylor & Francis in Heat Transfer Engineering
- Vol. 44 (15) , 1433-1451
Inverse Estimation of Breast Tumor Size and Location with Numerical Thermal Images of Breast Model Using Machine Learning Models
Early screening of cancer plays a vital role in successful treatment. Normally, the temperature of breast surface changes due to the size and location of the underlying tumor. Temperature patterns can be used to estimate the size and location of tumor by an inverse approach using machine learning algorithms. The present study aims to provide an efficient machine learning model that can be relied on to predict the size and location of the tumor using numerical thermal images. There is no availability of actual thermal images labeled with the size and location of the tumor. Consequently, successive numerical simulations are used to develop the numerical thermal image dataset with a three-dimensional breast model solved with COMSOL Multiphysics. The obtained numerical thermal images are uniquely labeled with the corresponding size and location of the tumor and trained using various machine learning regression models such as linear, support vector, K-nearest neighbor, and decision tree regression models. The results are analyzed using parity plots and mean absolute error. The present study found that the decision tree regression model outperformed the other machine learning models and improved the estimation accuracy by rejecting the numerical thermal images which are having slight variation in surface temperature.
- 15 August 2022
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 20 (5) , 544-554
Analytical investigation on thermo hydraulic performance augmentation of triangular duct solar air heater integrated with wavy fins
Present work deals with performance improvement of triangular duct solar air heater by integration of wavy fin on absorber plate. An analytical model has been developed for the investigation of design parameters such as fin pitch ratio with ranges 0.05–0.2 and fin amplitude ratio with ranges 0.025–0.125. MATLAB code is generated to solve the energy balance equations by iterative procedure. The influence of design parameters on effective thermal and thermal efficiency is presented and its influences are discussed. Increasing the fin pitch ratio decreases the thermal and thermo hydraulic efficiency drastically. The positive effect of fin amplitude ratio is observed; increasing of fin amplitude ratio improves the thermal efficiency and effective efficiency up to the critical Reynolds number. The peak thermal efficiency of 85% is observed and thermo hydraulic efficiency of 80.16% is found at fin pitch ratio of 0.05 and fin amplitude ratio of 0.125. The maximum thermo hydraulic performance enhancement is 15.7% as it compared simple conventional solar triangular duct air extractors. The design plots are developed to select the performance parameters to attain required temperature rise values.
- 15 August 2022
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 20 (5) , 544-554
Analytical investigation on thermo hydraulic performance augmentation of triangular duct solar air heater integrated with wavy fins
Present work deals with performance improvement of triangular duct solar air heater by integration of wavy fin on absorber plate. An analytical model has been developed for the investigation of design parameters such as fin pitch ratio with ranges 0.05–0.2 and fin amplitude ratio with ranges 0.025–0.125. MATLAB code is generated to solve the energy balance equations by iterative procedure. The influence of design parameters on effective thermal and thermal efficiency is presented and its influences are discussed. Increasing the fin pitch ratio decreases the thermal and thermo hydraulic efficiency drastically. The positive effect of fin amplitude ratio is observed; increasing of fin amplitude ratio improves the thermal efficiency and effective efficiency up to the critical Reynolds number. The peak thermal efficiency of 85% is observed and thermo hydraulic efficiency of 80.16% is found at fin pitch ratio of 0.05 and fin amplitude ratio of 0.125. The maximum thermo hydraulic performance enhancement is 15.7% as it compared simple conventional solar triangular duct air extractors. The design plots are developed to select the performance parameters to attain required temperature rise values.