Unai Zalabarria
Research Subjects
Unai Zalabarria has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Eloy Irigoyen
Universidad del País Vasco (UPV/EHU)
6 shared publications - Asier Salazar-Ramirez
Department of System Engineering and Automation, University of the Basque Country (UPV/EHU), 48013 Bilbao, Spain
3 shared publications Andrew Lowe
Institute of Biomedical Technologies, School of Engineering, Mathematical and Computer Sciences, Auckland University of Technology, Auckland, 1010, New Zealand
2 shared publicationsRaquel Martinez
Department of Systems Engineering and Automation, Faculty of Engineering of the UPV/EHU, Bilbao, ES, 48013
2 shared publicationsRaquel Martínez
University of the Basque Country (UPV/EHU)
2 shared publicationsJavier Arechalde
University of the Basque Country (UPV/EHU)
1 shared publication
Latest Publications
- 1 December 2020
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 197, 105681
Diagnosis of atrial fibrillation based on arterial pulse wave foot point detection using artificial neural networks
- 1 December 2020
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 197, 105681
Diagnosis of atrial fibrillation based on arterial pulse wave foot point detection using artificial neural networks
- Open Access
- 16 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 74118-74128
A Low-Cost, Portable Solution for Stress and Relaxation Estimation Based on a Real-Time Fuzzy Algorithm
Goal: This paper proposes a reliable stress and relaxation level estimation algorithm that is implemented in a portable, low-cost hardware device and executed in real time. The main objective of this work is to offer an affordable and “ready-to-go” solution for medical and personal environments, in which the detection of the arousal level of a person is crucial. Methods: To achieve meaningful identification of stress and relaxation, a fuzzy algorithm based on expert knowledge is built according to parameters extracted from physiological records. In addition to the heart rate, parameters extracted from the galvanic skin response and breath are employed to extend the results. Moreover, this algorithm achieves accurate results with a restricted computational load and can be implemented in a miniaturized low-cost prototype. The developed solution includes standard and actively shielded electrodes that are connected to an Arduino device for acquisition, while parameter extraction and fuzzy processing are conducted with a more powerful Raspberry Pi board. The proposed solution is validated using real physiological registers from 42 subjects collected using BIOPAC MP36 hardware. Additionally, a real-time acquisition, processing and remote cloud storage service is integrated via IoT wireless technology. Results: Robust identification of stress and relaxation is achieved, with F1 scores of 91.15% and 96.61%, respectively. Moreover, processing is performed using a 20-second sliding window; thus, only a small frame of context is required. Significance: This work presents a reliable solution for identifying stress and relaxation levels in real time, which can lead to the production of low-cost commercial devices for use in medical and personal environments.
- 16 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 74118-74128
Open AccessA Low-Cost, Portable Solution for Stress and Relaxation Estimation Based on a Real-Time Fuzzy Algorithm
Goal: This paper proposes a reliable stress and relaxation level estimation algorithm that is implemented in a portable, low-cost hardware device and executed in real time. The main objective of this work is to offer an affordable and “ready-to-go” solution for medical and personal environments, in which the detection of the arousal level of a person is crucial. Methods: To achieve meaningful identification of stress and relaxation, a fuzzy algorithm based on expert knowledge is built according to parameters extracted from physiological records. In addition to the heart rate, parameters extracted from the galvanic skin response and breath are employed to extend the results. Moreover, this algorithm achieves accurate results with a restricted computational load and can be implemented in a miniaturized low-cost prototype. The developed solution includes standard and actively shielded electrodes that are connected to an Arduino device for acquisition, while parameter extraction and fuzzy processing are conducted with a more powerful Raspberry Pi board. The proposed solution is validated using real physiological registers from 42 subjects collected using BIOPAC MP36 hardware. Additionally, a real-time acquisition, processing and remote cloud storage service is integrated via IoT wireless technology. Results: Robust identification of stress and relaxation is achieved, with F1 scores of 91.15% and 96.61%, respectively. Moreover, processing is performed using a 20-second sliding window; thus, only a small frame of context is required. Significance: This work presents a reliable solution for identifying stress and relaxation levels in real time, which can lead to the production of low-cost commercial devices for use in medical and personal environments.
- 1 January 2018
- Published by Elsevier in Neurocomputing
- Vol. 271, 48-57
An enhanced fuzzy algorithm based on advanced signal processing for identification of stress
- 1 January 2018
- Published by Elsevier in Neurocomputing
- Vol. 271, 48-57
An enhanced fuzzy algorithm based on advanced signal processing for identification of stress
- 1 October 2016
- Published by Springer Nature
- p. 301-312
Detection of Stress Level and Phases by Advanced Physiological Signal Processing Based on Fuzzy Logic
- 1 October 2016
- Published by Springer Nature
- p. 301-312