Michał Olinski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Michał Olinski has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Marco Ceccarelli
Department of Industrial Engineering, University of Rome Tor Vergata, 00133 Rome, Italy
5 shared publications A. Gronowicz
3 shared publications- Antoni Gronowicz
Wrocław University of Science and Technology (WUST)
2 shared publications - Daniele Cafolla
Swansea University, Swansea, UK
2 shared publications - Mateusz Fiedeń
Faculty of Mechanical Engineering, Wroclaw University of Science and Technology, 50-370 Wrocław, Poland
2 shared publications - A. Gronowicz1 shared publication
Latest Publications
- Open Access
Performance of an Inclinometer for Inertia-Based Robotic Stability Monitoring System Under Cross-Axis Angular Deviations
Autonomous heavy machinery and mobile robots require accurate real-time angular state monitoring to ensure stability and prevent tip-over accidents. However, sensor mounting imperfections and operating on slopes can introduce cross-axis distortions in inclination readings. This research investigates the angle tracking accuracy and cross-axis resilience of the IFM JD1121 industrial single-axis dynamic inclinometer. Experimental validation is performed on a custom mechatronic test stand driven by a stepper motor executing a repeatable 30 s motion profile from −30° to +90°. Cross-axis interference is evaluated across automated multi-trial runs under fixed lateral angular offsets of 0°, 10°, 20°, and 30°. A preliminary field test is conducted on a mobile demolition robot using a camera-tracked ArUco marker as an optical reference. Inclinometer performance is evaluated using statistical metrics, including maximum error, mean error, mean absolute error, and SD. Quantitative cross-axis sensitivity analysis revealed low coupling coefficient, while equivalence testing (TOST) confirmed that lateral roll offsets up to 30° cause very small degradation in pitch accuracy. The preliminary field test indicated stable on-platform tracking, supporting further development of the sensor for anti-tip safety monitoring in industrial mobile platforms/robots and heavy machinery.
Open AccessPerformance of an Inclinometer for Inertia-Based Robotic Stability Monitoring System Under Cross-Axis Angular Deviations
Autonomous heavy machinery and mobile robots require accurate real-time angular state monitoring to ensure stability and prevent tip-over accidents. However, sensor mounting imperfections and operating on slopes can introduce cross-axis distortions in inclination readings. This research investigates the angle tracking accuracy and cross-axis resilience of the IFM JD1121 industrial single-axis dynamic inclinometer. Experimental validation is performed on a custom mechatronic test stand driven by a stepper motor executing a repeatable 30 s motion profile from −30° to +90°. Cross-axis interference is evaluated across automated multi-trial runs under fixed lateral angular offsets of 0°, 10°, 20°, and 30°. A preliminary field test is conducted on a mobile demolition robot using a camera-tracked ArUco marker as an optical reference. Inclinometer performance is evaluated using statistical metrics, including maximum error, mean error, mean absolute error, and SD. Quantitative cross-axis sensitivity analysis revealed low coupling coefficient, while equivalence testing (TOST) confirmed that lateral roll offsets up to 30° cause very small degradation in pitch accuracy. The preliminary field test indicated stable on-platform tracking, supporting further development of the sensor for anti-tip safety monitoring in industrial mobile platforms/robots and heavy machinery.
- 30 June 2026
- Published by Springer Nature
- p. 300-307
Comparative Performance of Inertial Sensors for Mobile Robot Stability Monitoring
- 30 June 2026
- Published by Springer Nature
- p. 300-307
Comparative Performance of Inertial Sensors for Mobile Robot Stability Monitoring
- 2 January 2026
- Published by Springer Nature
- p. 138-152
Recent Advancements in Development of Knee Joint Assistive Devices at WUST
- 2 January 2026
- Published by Springer Nature
- p. 138-152
Recent Advancements in Development of Knee Joint Assistive Devices at WUST
- Open Access
- 21 January 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (3) , 1011
Development of a Simplified Human Body Model for Movement Simulations
The main goal of this paper is to develop a simplified model of the human body motion system that enables its application for movement simulations and the analysis of the kinematic and dynamic parameters occurring during the performance of activities. The model is established on the basis of the modified Hanavan model and consists of rigid solids with simple geometry that are connected mostly with spherical joints. Based on anthropometric data from the literature, a complete set of equations parameterizing the dimensions and mass of each segment was formulated. The equations depend on only two body measurements (height and mass). The model is built in the Adams system as a 3D numerical dynamic model and tested using data gathered with an IMU sensors system. A volunteer lifting an object with a bent spine from the ground with both hands is used for this purpose. Three angles (from the IMUs) are applied to each model’s joint to best simulate human movement and to analyze the angular displacements, velocities, and torques. These results are consistent with theoretical expectations and assumptions, thus proving that reproducing human movements with the developed model is possible and that it also allows various parameters of the human body to be obtained.
- 21 January 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (3) , 1011
Open AccessDevelopment of a Simplified Human Body Model for Movement Simulations
The main goal of this paper is to develop a simplified model of the human body motion system that enables its application for movement simulations and the analysis of the kinematic and dynamic parameters occurring during the performance of activities. The model is established on the basis of the modified Hanavan model and consists of rigid solids with simple geometry that are connected mostly with spherical joints. Based on anthropometric data from the literature, a complete set of equations parameterizing the dimensions and mass of each segment was formulated. The equations depend on only two body measurements (height and mass). The model is built in the Adams system as a 3D numerical dynamic model and tested using data gathered with an IMU sensors system. A volunteer lifting an object with a bent spine from the ground with both hands is used for this purpose. Three angles (from the IMUs) are applied to each model’s joint to best simulate human movement and to analyze the angular displacements, velocities, and torques. These results are consistent with theoretical expectations and assumptions, thus proving that reproducing human movements with the developed model is possible and that it also allows various parameters of the human body to be obtained.
- Open Access
Design and Experimental Characterization of Developed Human Knee Joint Exoskeleton Prototypes
This paper focuses on the experimental testing and characterisation of two designed and constructed prototypes of a human knee joint mechanism. The aim of the mechanical systems, presented as kinematic diagrams and 3D CAD drawings, is to reproduce the knee joint’s complex movement, in particular the flexion/extension in the sagittal plane, within a given range and constraints, while taking into account the trajectory of the joint’s instantaneous centre of rotation. The first prototype can simulate different movements by modifying its dimensions in real time using a linearly adjustable crossed four-bar mechanism. The second prototype has interchangeable cooperating components, with cam profiles that can be adapted to specific requirements. Both devices are built from 3D-printed parts and their characteristics are determined experimentally. Although many types of tests have been carried out, this research mainly aims to conduct experiments with volunteers. To this end, the IMU sensors measure the mechanisms’ movements, but the main source of the data is video analysis of the colour markers. For the purposes of postprocessing, the results in the form of numerical values and figures were computed by Matlab 2019b. To illustrate the prototypes’ capabilities, the results are shown as motion trajectories of selected tibia/femur points and the calculated knee joint’s flexion/extension angle.
Open AccessDesign and Experimental Characterization of Developed Human Knee Joint Exoskeleton Prototypes
This paper focuses on the experimental testing and characterisation of two designed and constructed prototypes of a human knee joint mechanism. The aim of the mechanical systems, presented as kinematic diagrams and 3D CAD drawings, is to reproduce the knee joint’s complex movement, in particular the flexion/extension in the sagittal plane, within a given range and constraints, while taking into account the trajectory of the joint’s instantaneous centre of rotation. The first prototype can simulate different movements by modifying its dimensions in real time using a linearly adjustable crossed four-bar mechanism. The second prototype has interchangeable cooperating components, with cam profiles that can be adapted to specific requirements. Both devices are built from 3D-printed parts and their characteristics are determined experimentally. Although many types of tests have been carried out, this research mainly aims to conduct experiments with volunteers. To this end, the IMU sensors measure the mechanisms’ movements, but the main source of the data is video analysis of the colour markers. For the purposes of postprocessing, the results in the form of numerical values and figures were computed by Matlab 2019b. To illustrate the prototypes’ capabilities, the results are shown as motion trajectories of selected tibia/femur points and the calculated knee joint’s flexion/extension angle.
- 27 September 2024
- Published by Springer Nature
- p. 134-142
An Experimental Characterisation of Developed Knee Joint Mechanism Prototypes
- 27 September 2024
- Published by Springer Nature
- p. 134-142
An Experimental Characterisation of Developed Knee Joint Mechanism Prototypes
- Open Access
- 13 October 2022
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 26 (14) , 1691-1701
Knee joint prototype based on cam mechanism – design and video analysis
The paper is focused on a design of mechanism accurately reproducing a complex motion in the sagittal plane of a human knee joint. The desired movement is modelled by applying specially designed shapes of cooperating cam elements based on the fixed and moving centroids of knee joint’s instantaneous centre of rotation. The mechanism’s CAD model and prototype are built using 3D printed elements, providing the possibility of interchanging the elements with cam profiles and adjusting the mechanism’s movement to individual needs. The mechanism movement is measured by analysing a video in Matlab and tracking colour markers on the prototype.
- 13 October 2022
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 26 (14) , 1691-1701
Open AccessKnee joint prototype based on cam mechanism – design and video analysis
The paper is focused on a design of mechanism accurately reproducing a complex motion in the sagittal plane of a human knee joint. The desired movement is modelled by applying specially designed shapes of cooperating cam elements based on the fixed and moving centroids of knee joint’s instantaneous centre of rotation. The mechanism’s CAD model and prototype are built using 3D printed elements, providing the possibility of interchanging the elements with cam profiles and adjusting the mechanism’s movement to individual needs. The mechanism movement is measured by analysing a video in Matlab and tracking colour markers on the prototype.
- Open Access
Displacement Estimation Based on Optical and Inertial Sensor Fusion
This article aims to develop a system capable of estimating the displacement of a moving object with the usage of a relatively cheap and easy to apply sensors. There is a growing need for such systems, not only for robots, but also, for instance, pedestrian navigation. In this paper, the theory for this idea, including data postprocessing algorithms for a MEMS accelerometer and an optical flow sensor (OFS), as well as the developed complementary filter applied for sensor fusion, are presented. In addition, a vital part of the accelerometer’s algorithm, the zero velocity states detection, is implemented. It is based on analysis of the acceleration’s signal and further application of acceleration symmetrization, greatly improving the obtained displacement. A test stand with a linear guide and motor enabling imposing a specified linear motion is built. The results of both sensors’ testing suggest that the displacement estimated by each of them is highly correct. Fusion of the sensors’ data gives even better outcomes, especially in cases with external disturbance of OFS. The comparative evaluation of estimated linear displacements, in each case related to encoder data, confirms the algorithms’ operation correctness and proves the chosen sensors’ usefulness in the development of a linear displacement measuring system.
Open AccessDisplacement Estimation Based on Optical and Inertial Sensor Fusion
This article aims to develop a system capable of estimating the displacement of a moving object with the usage of a relatively cheap and easy to apply sensors. There is a growing need for such systems, not only for robots, but also, for instance, pedestrian navigation. In this paper, the theory for this idea, including data postprocessing algorithms for a MEMS accelerometer and an optical flow sensor (OFS), as well as the developed complementary filter applied for sensor fusion, are presented. In addition, a vital part of the accelerometer’s algorithm, the zero velocity states detection, is implemented. It is based on analysis of the acceleration’s signal and further application of acceleration symmetrization, greatly improving the obtained displacement. A test stand with a linear guide and motor enabling imposing a specified linear motion is built. The results of both sensors’ testing suggest that the displacement estimated by each of them is highly correct. Fusion of the sensors’ data gives even better outcomes, especially in cases with external disturbance of OFS. The comparative evaluation of estimated linear displacements, in each case related to encoder data, confirms the algorithms’ operation correctness and proves the chosen sensors’ usefulness in the development of a linear displacement measuring system.
- 14 June 2019
- Published by Springer Nature
- p. 43-52
Interactive device supporting ankle joint rehabilitation
- 14 June 2019
- Published by Springer Nature
- p. 43-52
Interactive device supporting ankle joint rehabilitation