RBRavindra Birajdar

Ravindra Birajdar

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ravindra Birajdar has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Critical Hydraulic Eccentricity Estimation in Vertical Turbine Pump Impeller to Control Vibration

    by Ravindra S. Birajdar, Appasaheb A. Keste, Shravan H. Gawande

    In many applications, pumps are tested against standard specifications to define the maximum allowable vibration amplitude limits of a pump. It is essential to identify the causes of vibration and methods to attenuate the same to ensure the safe and satisfactory operation of a pump. Causes of vibration can be classified mainly into mechanical and hydraulic nature. Respective unbalance masses are the two major factors which cause dynamic effects and excitation forces leading to undesirable vibrations. In this paper, the procedure of vibration magnitude measurement of a vertical turbine pump at site and the process of dynamic balancing to measure mechanical unbalance of an impeller are explained. After that, the impact of hydraulic eccentricity on the vibration displacement of a vertical turbine pump has been explained using numerical simulation procedure based on “One-way Fluid Structure Interaction (FSI).” The experimental results from a pump at site are used to compare the numerical results. After the solver validation, the one-way FSI approach is used to find the critical hydraulic eccentricity magnitude of a vertical turbine pump impeller to limit the vibration magnitudes on motor component to less than 100 μm. From the numerical simulations, it is deduced that the critical hydraulic eccentricity should be limited to 400 μm in and direction. The process can be used as a guideline procedure for limiting the hydraulic unbalance in vertical turbine pumps by limiting the hydraulic eccentricity.


  • Open Access

    Vibration Control of Vertical Turbine Pump by Optimization of Vane Pitch Tolerances of an Impeller Using Statistical Techniques

    by Ravindra Birajdar, Appasaheb Keste, Shravan Gawande

    The objective of the study is to find the tolerance on vane pitch dimensions of a Vertical Turbine (VT) pump impeller. For this purpose, the study is divided into two parts viz. to find the critical hydraulic eccentricity of a VT pump impeller by way of numerical simulations and design of experiments to find the vane pitch tolerance using critical hydraulic eccentricity. The effect of impeller vane pitch deviations on hydraulic unbalance is examined for a vertical turbine pump using Design of Experiments (DOE). A suitable orthogonal matrix has been selected with vane pitch at different axial locations of an impeller as the control factors. Hydraulic eccentricity, which is the output of the DOE experiments is analyzed using S/N ratio, ANOM and regression analysis to find the significant control factor effecting the hydraulic unbalance and hence vibrations. The vane pitch deviation at outlet and inlet of impeller shroud geometry are found to be the most critical factor affecting the pump vibrations.

  • Optimization of Single-Phase Induction Motor

    by Mayuri Karpe, Santosh Ghosh, Naveen Shindhe, Ravindra Birajdar, Dilip Bhave

    Induction Motors are responsible for consumption of nearly 40% of electricity globally, as these are the driving force behind each fan, compressor, pump and nearly every mechanical load which have rotational motion. About 30 million new electric motors are put in use every year for industrial application alone. Despite the advent of permanent magnet-based motors, single phase induction motors (SPIM) out numbers all other types of induction motors, because of its simple and robust construction and low cost. Hence small improvement in the performance of SPIM may greatly impact energy consumption worldwide and reduce carbon footprint eventually, however, studies related to SPIM is neglected by the researchers as these are not covered under the minimum efficiency standards. This paper presents design optimization technique of SPIM with the objective functions of maximization of efficiency while ensuring minimum material and tooling cost implication. For the current work a 0.5 hp, 2 pole motor has been considered as a sample case. Design approaches for optimization of capacitor start and run motor with the help of the double revolving theory is presented. The optimized design is validated by Finite Element Analysis and the predicted result of FEA analysis is compared with test result and found to be in good agreement.


  • Open Access

    Prediction of flow induced vibrations in vertical turbine pumps using one-way fluid-structure interaction

    by Ravindra Birajdar, Appasaheb Keste

    Centrifugal pumps/vertical turbine pumps are important and critical equipment for operation in the power generation, water supply, process industries and petrochemical industries. All centrifugal and vertical turbine pumps have rotors and structures that can vibrate in response to excitation forces. Mechanical and hydraulic unbalance are the two major factors which can create dynamic effects in terms of pump vibrations. In many cases the resulting hydraulic forces due to hydraulic unbalance has much the same effect as the mechanical unbalance. The vibrations in the pumps must be within acceptable limits of applicable standards. If there is higher level of vibrations, it not only leads to operational inefficiencies but also causes pump failures. Hence, it is very important for designers to understand the dominating fact of unbalance force and its origin. The prediction of vibrations in a vertical turbine pump due to the hydro dynamic forces, using numerical methods can help a designer to accomplish a successful design. The interaction between solid and fluid in present case can be completed by one-way coupling method. The one-way fluid-structure interaction approach is presented in present paper to predict the vibrations at specific operating condition which has good correlation with the test data. The advantage of reduced computational effort in this approach can be utilized during initial design stage. In this paper, a case study of one-way FSI approach of a vertical turbine pump is discussed. After detailed explanation about the CFD results, one-way coupling approach is explained with comparison of vibration displacements in both numerical and test data.


  • Evaluation of Indian power sector reform strategies and improvement direction though DEA

    by Santosh Ghosh, Vinod Kumar Yadav, Gitanjali Mehta, Ravindra Birajdar

    This paper evaluates relative performances of power distribution utilities of 28 states of India for the year 2012-13, through application of Data Envelopment Analysis (DEA). Benchmark utilities have been identified for each non-frontier utilities to emulate the best practices for improvement. Further slack analysis is carried out to identify the root causes of inefficiencies of the utilities lying away from the frontier. About 86% of the distribution utilities are found to be digressing from efficiency frontier. The main cause of the inefficiencies is observed to be excessive distribution line length compared to the revenue realized and number of consumers served by those. Specific recommendations have been made for the policy level changes required for improving the overall performance of the distribution utilities and socio-economic standing of the rural population of India.


  • Study on Vibrations in Centrifugal Pump Due to Dynamic Loading

    by Ravindra S. Birajdar, A. A. Keste

    Study on Vibrations in Centrifugal Pump Due to Dynamic Loading

  • Numerical Simulation of Regenerative Pump

    by Rahul Verma, Shyam Shukla, Ravi Birajdar, Nirmal Tiwari


  • Design of high performance induction motor through multi objective and multi domain optimization

    by Santosh Ghosh, Hemant Memane, M. Karpe, Ravindra Birajdar, V. K. Yadav, V. Mukherjee

    This paper presents the holistic approach for design optimization of induction motors with the objective to have overall better and environment friendly performance, going beyond mere better efficiency. Generally while motor design optimization the improvements are done in one's own domain in isolation. However to improve the overall performance of machines, all the inter related design aspects i.e. desired torque speed characteristics, electromagnetic field distribution, I2R loss distribution, efficiency, thermal behavior, aerodynamic and electromagnetic noise and vibration etc. needs to be attended, through collaborative engineering. In the present work a 15 kW, 4 Pole Induction Motor has been considered as a sample case for design optimization using Finite Element Analysis tool for electromagnetic field analysis. Cooling Circuit is optimized by carrying out numerical simulation of different fan geometries using Computational Fluid Dynamics tool, with the objective to increase cooling efficiency and reduce aerodynamic noise.


  • Status Check: Journey of India's Energy Sustainability through Renewable Sources

    by S. Ghosh, V.K. Yadav, G. Mehta, V. Mukherjee, R. Birajdar