RSRobert Schuon

Robert Schuon

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Robert Schuon has a total of 41 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    First Investigation of a Eustachian Tube Stent in Experimentally Induced Eustachian Tube Dysfunction

    by Katharina Schmitt, Malena Timm, Philipp Krüger, Niels Oppel, Alexandra Napp, Friederike Pohl, Robert Schuon, Lisa Kötter, Marion Bankstahl, Thomas Lenarz, et al.

    Unmet needs in the treatment of chronic otitis media and Eustachian tube dysfunction (ETD) triggered the development of stents for the Eustachian tube (ET). In this study, for the first time, stents were placed in an artificially blocked ET to evaluate stent function. Eight adult female sheep were injected with stabilized hyaluronic acid (HA) on both sides to induce ETD. Subsequently, a tapered nitinol ET stent was inserted on one side, and animals were examined bilaterally by endoscopy, tympanometry, cone beam computed tomography, and final histology. Seven of the stents were placed in the desired cartilaginous portion of the ET. At the end of the study, one stented side appeared slightly open; all other ET orifices were closed. Tympanometry revealed re-ventilation of the middle ear in four out of seven correctly stented animals within 3 to 6 weeks after stent insertion. The major amount of HA was found at the pharyngeal orifice of the ET anterior to the stent. Thus, the stent position did not completely align with the HA position. While a functional analysis will require refinement of the experimental setup, this study provides first promising results for stent insertion in a sheep model of ETD.


  • Open Access

    Long-Term Preclinical Evaluation of a Permanent Stent Developed for the Human Eustachian Tube

    by Katharina Schmitt, Malena Timm, Philipp Krüger, Niels Oppel, Alexandra Napp, Friederike Pohl, Robert Schuon, Andreas Kampmann, Lisa Kötter, Marion Bankstahl, et al.

    The Eustachian tube (ET) is a bottleneck when it comes to middle ear (ME) health. If its function is impaired, this can lead to serious consequences for the patient, such as hearing problems or deafness. Therefore, this study investigated a tapered nitinol stent (3–5 mm × 14 mm) for the human ET as a potential new permanent treatment for chronic Eustachian tube dysfunction (ETD) and thus ME ventilation disorders. The self-expanding stent was inserted unilaterally into the ET of 24 sheep with observation periods of 3, 6, and 12 months. Local tissue effects and the safety of the stent insertion were analyzed based on regular endoscopic checks, weekly tympanometry measurements, final imaging, and histological examinations. The animals showed no stent-related health restrictions. However, the individual anatomy and stenting procedure had an influence on the results. The tissue reaction in the endoscopic examinations was mild even though no concomitant antibiotics were administered. After all three monitoring periods, stented ETs had a significantly larger ET lumen than the non-stented contralateral ETs. However, tissue growth was detected in the stent. Overall, the first long-term study on an ET stent showed that the tapered ET stent could be a promising treatment option for ETD.


  • Open Access

    Investigation of Stent Prototypes for the Eustachian Tube in Human Donor Bodies

    by Lena Rosenbusch, Robert Schuon, Tamara Wilfling, Philipp Krüger, Kerstin Lebahn, Samuel John, Olga Sahmel, Niels Grabow, Marko Schulze, Andreas Wree, et al.

    Chronic otitis media is often connected to Eustachian tube dysfunction. As successful treatment cannot be guaranteed with the currently available options, the aim is to develop a stent for the Eustachian tube (ET). Over the course of this development, different prototypes were generated and tested in ex vivo experiments. Four different prototypes of an ET stent and one commercially available coronary stent were implanted in the ET of seven human donor bodies. The position of the stents was verified by cone beam CT. The implanted ETs were harvested, embedded in resin and ground at 200 µm steps. Resulting images of the single steps were used to generate 3D models. The 3D models were then evaluated regarding position of the stent in the ET, its diameters, amount of squeezing, orientation of the axes and other parameters. Virtual reconstruction of the implanted ET was successful in all cases and revealed one incorrect stent placement. The cross-section increased for all metal stents in direction from the isthmus towards the pharyngeal orifice of the ET. Depending on the individual design of the metal stents (open or closed design), the shape varied also between different positions along a single stent. In contrast, the cross-section area and shape remained constant along the polymeric prototype. With the current investigation, insight into the behavior of different prototypes of ET stents was gained, which can help in defining the specifications for the intended ET stent.


  • Open Access

    Functional cleft palate surgery

    by Ulrich Joos, Anthony F. Markus, Robert Schuon


  • Open Access

    Intravascular Ultrasonography (IVUS)—A Tool for Imaging the Eustachian Tube?

    by Niels Oppel, Gerrit Paasche, Andre Bleich, Thomas Lenarz, Robert Schuon

    The Eustachian tube (ET) has a key role in the pathogenesis of otitis media. Until now, there has been a lack of meaningful imaging methods to investigate the ET and its surrounding tissue. The aim of the current study was to investigate the possibilities of imaging the ET using Intravascular Ultrasonography (IVUS). ETs from sheep were scanned ex vivo and in vivo with different IVUS probes. In addition to native ETs, water was also used to improve coupling. Scans were subsequently compared with histological sections and a 3D model of the ET. In addition, ETs with a stenosis induced by a hyaluronic acid depot, after stent insertion, and during lower jaw movement were examined. The IVUS catheter was inserted into the ET lumen without any problems or injuries in all cases. The surrounding structures of the ET were identified in the ultrasound image. In addition, a change in size of the ET lumen due to movement was observed, and the position of the stent and the depot of hyaluronic acid could be examined. With the use of IVUS, a non-invasive possibility to examine the ET over its course with the adjacent structures as well as after different treatments is presented.


  • Open Access

    Development of an In Vivo Model for Eustachian Tube Dysfunction

    by Niels Oppel, Malena Ezzat, Philipp Krüger, Katharina Schmitt, Alexandra Napp, Friederike Pohl, Andre Bleich, Thomas Lenarz, Tobias Stein, Gerrit Paasche, et al.

    Otitis media is often connected to Eustachian tube dysfunction (ETD). Until now, there was no large animal model available for the examination of new treatment methods such as stents for the Eustachian tube (ET). Thus, the aim of the study was to develop a method to reproducibly induce ETD by injection of fillers and without permanent closure of the ET. Tools for safe injection of hyaluronic acid (HA) in the surrounding of the ET were developed. In ex vivo experiments, HA mixed with Imeron® was injected close to the nasopharyngeal orifice of the ET of blackface sheep. The established depot was visualized using cone beam computer tomography and magnetic resonance imaging, and stents could be placed into the ET. A reliable position of the HA depot was achieved. This method was transferred to in vivo, and middle ear ventilation was investigated by tympanometry. ETD was achieved with amounts of 2.5 mL HA or higher. None of the animals showed any sign of discomfort or complications. The induced ETD lasted for 3 to 13 (maximum observation period) weeks and was also combined with middle ear effusion. A model of ETD based on injection of HA next to the ET was successfully established and is now available to test novel treatment options for ET functionality.


  • Open Access

    Functional aspects of the Eustachian tube by means of 3D-modeling

    by Robert Schuon, Josef Schwarzensteiner, Gerrit Paasche, Thomas Lenarz, Samuel John

    The extent of dysfunction of the Eustachian tube (ET) is relevant in understanding the pathogenesis of secondary otological diseases such as acute or chronic otitis media. The underlying mechanism of ET dysfunction remains poorly understood except for an apparent genesis such as a nasopharyngeal tumor or cleft palate. To better describe the ET, its functional anatomy, and the biomechanical valve mechanism and subsequent development of diagnostic and interventional tools, a three-dimensional model based on thin-layer histology was created from an ET in this study. Blackface sheep was chosen as a donor. The 3-D model was generated by the coherent alignment of the sections. It was then compared with the cone-beam computed tomography dataset of the complete embedded specimen taken before slicing. The model shows the topographic relation of the individual components, such as the bone and cartilage, the muscles and connective tissue, as well as the lining epithelium with the lumen. It indicates a limited spiraling rotation of the cartilaginous tube over its length and relevant positional relationships of the tensor and levator veli palatine muscles.


  • Open Access

    Functional Aspects of the Eustachian Tube by Means of 3D-Modeling

    by Schuon Robert, Josef Schwarzensteiner, Gerrit Paasche, Lenarz Thomas, Samuel John

    The extent of dysfunction of the Eustachian tube (ET) is relevant in understanding the pathogenesis of secondary otological diseases such as acute or chronic otitis media. The underlying mechanism of ET dysfunction remains poorly understood except for an apparent genesis such as a nasopharyngeal tumor or cleft palate. To better describe the ET, its functional anatomy, and the biomechanical valve mechanism and subsequent development of diagnostic and interventional tools, a three-dimensional model based on thin-layer histology was created from an ET in this study. Blackface sheep was chosen as a donor. The 3-D model was generated by the coherent alignment of the sections. It was then compared with the cone-beam computed tomography dataset of the complete embedded specimen taken before slicing. The model shows the topographic relation of the individual components, such as the bone and cartilage, the muscles and connective tissue, as well as the lining epithelium with the lumen. It indicates a limited spiraling rotation of the cartilaginous tube over its length and relevant positional relationships of the tensor and levator veli palatine muscles.

  • Intraluminal three-dimensional optical coherence tomography – a tool for imaging of the Eustachian tube?

    by R Schuon, B Mrevlje, B Vollmar, T Lenarz, G Paasche

    ObjectivesThe cause of Eustachian tube dysfunction often remains unclear. Therefore, this study aimed to examine the feasibility and possible diagnostic use of optical coherence tomography in the Eustachian tube ex vivo.MethodsTwo female blackface sheep cadaver heads were examined bilaterally. Three conditions of the Eustachian tube were investigated: closed (resting position), actively opened and stented. The findings were compared (and correlated) with segmented histological cross-sections.ResultsIntraluminal placement of the Eustachian tube with the optical coherence tomography catheter was performed without difficulty. Regarding the limited infiltration depth of optical coherence tomography, tissues can be differentiated. The localisation of the stent was accurate as was the lumen.ConclusionThe application of optical coherence tomography in the Eustachian tube under these experimental conditions is considered to be a feasible, rapid and non-invasive diagnostic method, with possible diagnostic value for determining the luminal shape and superficial lining tissue of the Eustachian tube.


  • Open Access

    Stenting the Eustachian tube to treat chronic otitis media - a feasibility study in sheep

    by Friederike Pohl, Robert A. Schuon, Felicitas Miller, Andreas Kampmann, Eva Bültmann, Christian Hartmann, Thomas Lenarz, Gerrit Paasche

    Untreated chronic otitis media severely impairs quality of life in affected individuals. Local destruction of the middle ear and subsequent loss of hearing are common sequelae, and currently available treatments provide limited relief. Therefore, the objectives of this study were to evaluate the feasibility of the insertion of a coronary stent from the nasopharynx into the Eustachian tube in-vivo in sheep and to make an initial assessment of its positional stability, tolerance by the animal, and possible tissue reactions. Bilateral implantation of bare metal cobalt-chrome coronary stents of two sizes was performed endoscopically in three healthy blackface sheep using a nasopharyngeal approach. The postoperative observation period was three months. Stent implantation into the Eustachian tube was feasible with no intra- or post-operative complications. Health status of the sheep was unaffected. All stents preserved their cylindrical shape. All shorter stents remained in position and ventilated the middle ear even when partially filled with secretion or tissue. One of the long stents became dislocated toward the nasopharynx. Both of the others remained fixed at the isthmus but appeared to be blocked by tissue or secretion. Tissue overgrowth on top of the struts of all stents resulted in closure of the tissue-lumen interface. Stenting of the Eustachian tube was successfully transferred from cadaver studies to an in-vivo application without complications. The stent was well tolerated, the middle ears were ventilated, and clearance of the auditory tube appeared possible. For fixation, it seems to be sufficient to place it only in the cartilaginous part of the Eustachian tube.