Marta Raurell-Torredà
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Marta Raurell-Torredà has a total of 393 co-authors. Here are the top co-authors by number of shared publications:
- Angel Romero-Collado
Nursing Department, University of Girona, Girona, Spain
8 shared publications - Susana Arias Rivera
Doctoral Program in Nursing and Health, University of Barcelona, Barcelona, Spain; Hospital Universitario de Getafe, Madrid, Spain; CIBER Enfermedades Respiratorias, Instituto de Salud Carlos III, Madrid, Spain
8 shared publications Fernando Frutos-Vivar
6 shared publicationsSusana Arias-Rivera
6 shared publications- Fernando Frutos-Vivar
Intensive Care Unit Hospital Universitario de Getafe Getafe (Madrid) Spain
4 shared publications - Lorena Oteiza-López
Intensive Care Unit Hospital Universitario de Getafe Getafe (Madrid) Spain
4 shared publications
Latest Publications
- Open Access
- 21 August 2026
- Published by Associação de Medicina Intensiva Brasileira in Critical Care Science
- Vol. 38
Safety recommendations on laboratory and blood count values for early mobilization in critically ill adults: an expert consensus
Although early mobilization is a cornerstone of modern critical care for reducing intensive care unit-acquired weakness, the duration of mechanical ventilation, and length of stay, its implementation remains highly variable due to the absence of standardized laboratory criteria to guide clinical decision-making. Therefore, this study aimed to generate safety recommendations regarding laboratory and blood […] Abstract Although early mobilization is a cornerstone of modern critical care for reducing intensive care unit-acquired weakness, the duration of mechanical ventilation, and length of stay, its implementation remains highly variable due to the absence of standardized laboratory criteria to guide clinical decision-making. Therefore, this study aimed to generate safety recommendations regarding laboratory and blood […]
- 21 August 2026
- Published by Associação de Medicina Intensiva Brasileira in Critical Care Science
- Vol. 38
Open AccessSafety recommendations on laboratory and blood count values for early mobilization in critically ill adults: an expert consensus
Although early mobilization is a cornerstone of modern critical care for reducing intensive care unit-acquired weakness, the duration of mechanical ventilation, and length of stay, its implementation remains highly variable due to the absence of standardized laboratory criteria to guide clinical decision-making. Therefore, this study aimed to generate safety recommendations regarding laboratory and blood […] Abstract Although early mobilization is a cornerstone of modern critical care for reducing intensive care unit-acquired weakness, the duration of mechanical ventilation, and length of stay, its implementation remains highly variable due to the absence of standardized laboratory criteria to guide clinical decision-making. Therefore, this study aimed to generate safety recommendations regarding laboratory and blood […]
- 13 June 2026
- Published by Elsevier in Medicina Intensiva (English Edition)
- Vol. 50 (9) , 502533
Response to: “Methodological considerations on the validation of the FRAIL-España scale in critically ill patients: Comments on Arias-Rivera et al.”
- 13 June 2026
- Published by Elsevier in Medicina Intensiva (English Edition)
- Vol. 50 (9) , 502533
Response to: “Methodological considerations on the validation of the FRAIL-España scale in critically ill patients: Comments on Arias-Rivera et al.”
- Open Access
- 23 May 2026
- Published by Elsevier in Nurse Education in Practice
- Vol. 94, 104865
Spanish adaptation and psychometric analysis of the “USE questionnaire” for virtual reality
- 23 May 2026
- Published by Elsevier in Nurse Education in Practice
- Vol. 94, 104865
Open AccessSpanish adaptation and psychometric analysis of the “USE questionnaire” for virtual reality
- Open Access
- 16 January 2026
- Published by Wiley in Nursing in Critical Care
- Vol. 31 (1) , e70343
Effectiveness of Closed Blood‐Sampling Devices in Critically Ill Adults: A Feasibility Trial
Background: Anaemia in critically ill patients is often worsened by diagnostic blood sampling. Closed blood sampling devices (CBSDs) may reduce iatrogenic blood loss and transfusion needs. However, robust evidence of their effectiveness and feasibility in the intensive care unit (ICU) setting is lacking. Aim: To assess the feasibility of conducting a multicentre randomised controlled trial (RCT) evaluating the effectiveness of CBSDs in reducing transfusion requirements in critically ill adults. Study Design: A two‐centre, open‐label, feasibility RCT was conducted in two Spanish university hospitals between November 2024 and March 2025. Patients with an ICU stay of 24 h who were expected to have an arterial catheter for at least 72 h longer were randomised to either a CBSD group (intervention) or standard practice (control). Primary outcome was feasibility (recruitment rate, intervention fidelity and dropout). Secondary outcomes included transfusion rates, discard volume and catheter‐related adverse events. Data were collected over a maximum of 21 days or until ICU discharge or catheter removal. As this was a feasibility study with a small sample size, no statistical inference analyses were performed. Results: Of 678 patients screened, 9.3% ( n = 63) were eligible, and of those eligible, 76.2% ( n = 48) were enrolled. After exclusions and losses, 31 patients were analysed (12 intervention, 19 control). Low eligibility was mainly due to short catheter dwell times and advanced monitoring needs with a Flotrac system. Intervention fidelity was suboptimal in four patients in the intervention group because one of the ICUs routinely used a venous route for blood gas sampling, despite patients having the CBSD in an arterial line. Thirteen patients (27.1%) were lost to follow‐up for the same reasons as the low eligibility findings. There were no missing data (0%). Transfusion rates per 100 catheter days were lower in the intervention group (5.2 vs. 15.6). Discard volume per 100 catheter days was substantially reduced (53.1 mL vs. 970.7 mL). No catheter‐related bacteraemias occurred. Conclusions: A full‐scale RCT evaluating CBSDs in ICU patients is feasible with protocol modifications, including broader site participation and improved device integration with advanced monitoring systems. Preliminary data suggest that CBSDs may reduce transfusion requirements and blood loss in critically ill patients. Relevance to Clinical Practice: Nurses’ involvement in the prevention of iatrogenic anaemia is key. CBSDs appear to be a feasible strategy for reducing blood loss associated with blood tests, with preliminary results linking their use to a decrease in the need for transfusions. If this is confirmed in the final clinical trial, it would mean greater safety for patients by avoiding complications linked to transfusions and would contribute to environmental sustainability by reducing the production of carbon dioxide associated with the process of collecting, storing and distributing red blood cells. Trial Registration: NCT06478160
- 16 January 2026
- Published by Wiley in Nursing in Critical Care
- Vol. 31 (1) , e70343
Open AccessEffectiveness of Closed Blood‐Sampling Devices in Critically Ill Adults: A Feasibility Trial
Background: Anaemia in critically ill patients is often worsened by diagnostic blood sampling. Closed blood sampling devices (CBSDs) may reduce iatrogenic blood loss and transfusion needs. However, robust evidence of their effectiveness and feasibility in the intensive care unit (ICU) setting is lacking. Aim: To assess the feasibility of conducting a multicentre randomised controlled trial (RCT) evaluating the effectiveness of CBSDs in reducing transfusion requirements in critically ill adults. Study Design: A two‐centre, open‐label, feasibility RCT was conducted in two Spanish university hospitals between November 2024 and March 2025. Patients with an ICU stay of 24 h who were expected to have an arterial catheter for at least 72 h longer were randomised to either a CBSD group (intervention) or standard practice (control). Primary outcome was feasibility (recruitment rate, intervention fidelity and dropout). Secondary outcomes included transfusion rates, discard volume and catheter‐related adverse events. Data were collected over a maximum of 21 days or until ICU discharge or catheter removal. As this was a feasibility study with a small sample size, no statistical inference analyses were performed. Results: Of 678 patients screened, 9.3% ( n = 63) were eligible, and of those eligible, 76.2% ( n = 48) were enrolled. After exclusions and losses, 31 patients were analysed (12 intervention, 19 control). Low eligibility was mainly due to short catheter dwell times and advanced monitoring needs with a Flotrac system. Intervention fidelity was suboptimal in four patients in the intervention group because one of the ICUs routinely used a venous route for blood gas sampling, despite patients having the CBSD in an arterial line. Thirteen patients (27.1%) were lost to follow‐up for the same reasons as the low eligibility findings. There were no missing data (0%). Transfusion rates per 100 catheter days were lower in the intervention group (5.2 vs. 15.6). Discard volume per 100 catheter days was substantially reduced (53.1 mL vs. 970.7 mL). No catheter‐related bacteraemias occurred. Conclusions: A full‐scale RCT evaluating CBSDs in ICU patients is feasible with protocol modifications, including broader site participation and improved device integration with advanced monitoring systems. Preliminary data suggest that CBSDs may reduce transfusion requirements and blood loss in critically ill patients. Relevance to Clinical Practice: Nurses’ involvement in the prevention of iatrogenic anaemia is key. CBSDs appear to be a feasible strategy for reducing blood loss associated with blood tests, with preliminary results linking their use to a decrease in the need for transfusions. If this is confirmed in the final clinical trial, it would mean greater safety for patients by avoiding complications linked to transfusions and would contribute to environmental sustainability by reducing the production of carbon dioxide associated with the process of collecting, storing and distributing red blood cells. Trial Registration: NCT06478160
- Open Access
- 23 September 2025
- Published by Elsevier in Medicina Intensiva (English Edition)
- Vol. 50 (1) , 502259
Validity of the FRAIL-España scale for critically ill patients
- 23 September 2025
- Published by Elsevier in Medicina Intensiva (English Edition)
- Vol. 50 (1) , 502259
Open AccessValidity of the FRAIL-España scale for critically ill patients
- 27 August 2025
- Published by Elsevier in Enfermería Intensiva (English ed.)
- Vol. 36 (3) , 500563
Teamwork training methodology: Five editions of the TeamSTEPPS® course
- 27 August 2025
- Published by Elsevier in Enfermería Intensiva (English ed.)
- Vol. 36 (3) , 500563
Teamwork training methodology: Five editions of the TeamSTEPPS® course
- 18 August 2025
- Published by Elsevier in Enfermería Intensiva (English ed.)
- Vol. 36 (3) , 500558
Validity and sensitivity to change of the Clinical Frailty Scale-España in patients admitted to intensive care
- 18 August 2025
- Published by Elsevier in Enfermería Intensiva (English ed.)
- Vol. 36 (3) , 500558
Validity and sensitivity to change of the Clinical Frailty Scale-España in patients admitted to intensive care
- Open Access
- 21 July 2025
- Published by Elsevier in Medicina Intensiva (English Edition)
- Vol. 50 (1)
Validez de la escala FRAIL-España en pacientes críticos
- 21 July 2025
- Published by Elsevier in Medicina Intensiva (English Edition)
- Vol. 50 (1)
Open AccessValidez de la escala FRAIL-España en pacientes críticos
- Open Access
- 15 July 2025
- Published by Elsevier in Teaching and Learning in Nursing
- Vol. 20 (4) , e1163-e1169
Acquisition of physical assessment skills among undergraduate nursing students using simulation-based assessment: A mixed-methods study
- 15 July 2025
- Published by Elsevier in Teaching and Learning in Nursing
- Vol. 20 (4) , e1163-e1169
Open AccessAcquisition of physical assessment skills among undergraduate nursing students using simulation-based assessment: A mixed-methods study