NCNarasimhan Chitra

Narasimhan Chitra

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Narasimhan Chitra has a total of 5 co-authors. Here are the top co-authors by number of shared publications:

  • I. B. Vijayalakshmi

    Department of Pediatric Cardiology, Sri Jayadeva Institute of Cardiovascular Sciences and Research, Bengaluru, Karnataka, India

    2 shared publications
  • C. N. Manjunath

    Department of Pediatric Cardiology, Sri Jayadeva Institute of Cardiovascular Sciences and Research, Bengaluru, Karnataka, India

    1 shared publication
  • I. B. Vijayalakshmi

    Department of Pediatric Cardiology, Super Specialty Hospital (Pradhana Mantri Swasthya Suraksha Yojana), Bengaluru Medical College and Research Institute, Bengaluru, Karnataka, India

    1 shared publication
  • Jayan Praveen

    From the Sri Jayadeva Institute of Cardiovascular Sciences and Research Karnataka India

    1 shared publication
  • Simha Rao Prasanna

    From the Sri Jayadeva Institute of Cardiovascular Sciences and Research Karnataka India

    1 shared publication

Latest Publications

  • Open Access

    Giant Left Ventricular Cardiac Tumor in a Neonate

    by Narasimhan Chitra, I. B. Vijayalakshmi, C. N. Manjunath

    Primary cardiac tumors in the fetuses and neonates are uncommon. The most common are rhabdomyomas. Echocardiography is the primary diagnostic tool for the detection of a cardiac tumor. We report a rare case of neonatal giant intracardiac left ventricular teratoma.


  • Fetal echocardiography for early detection of congenital heart diseases

    by Narasimhan Chitra, I. B. Vijayalakshmi

    Fetal echocardiography is a complete two-dimensional and Doppler ultrasound evaluation of the human fetal cardiovascular system. It is completely noninvasive, harmless, and also serves as the fetal electrocardiogram. To analyze the fetal echocardiographic cases referred to a tertiary cardiac center. A total of 478 cases of fetal echocardiograms performed over a period of 5.5 years were compiled and analyzed. Details regarding gestational age, maternal, family history, exposure to teratogens, and reason for referral were recorded. The average gestational age at referral was 24.8 ± 4.6 weeks and maternal age was 24.7 ± 4.3 years. Indications for referrals were abnormal fetal cardiac scan in 128 (26.8 %), previous sibling with congenital heart disease (CHD) in 99 (20.7 %), maternal indications in 87 (18.2 %), echogenic intracardiac focus (EIF) in 87 (18.2 %), high risk in 50 (10.5 %), rhythm problems in 21 (4.4 %), and others (extracardiac malformations) in 6 (1.2 %). In the 87 CHD cases diagnosed, nearly 70 % had complex CHD and 66.7 % were referred only after 22 weeks of gestation. A further 103 cases had EIF, 17 cases had fetal arrhythmia, 3 cases had cardiac masses, and the remaining 268 cases had normal fetal echocardiograms. Fetal echocardiography can effectively identify abnormal hearts and has enhanced prenatal detection of CHD. The concern in the Indian scenario is the late referrals, lack of follow-up, and financial difficulties, all of which conspire against the chance of the fetus with heart disease getting appropriate treatment.


  • Challenges in Device Closure of a Large Patent Ductus Arteriosus in Infants Weighing Less Than 6 Kg

    by I. B. Vijayalakshmi, Narasimhan Chitra, Jayan Praveen, Simha Rao Prasanna

    Transcatheter closure of patent ductus arteriosus (PDA) has replaced surgery in most institutions. Despite improvements in techniques and the devices available, closure of large PDA in very small infants remains a challenge. To assess the challenges, feasibility, and efficacy of device closure of large PDA, in infants weighing ≤6 kg. Analysis of device closure of a PDA was done in 61 infants ≤6 kg. Their ages, ranged from 9 days-12 months (mean 8.9 months), weight ranged from 2.2 to 6 kg (mean 5.3 kg), and PDA measured 3.2-8.7 mm (mean 4.8 mm). The fluoroscopy time was 3-18 minutes. The largest device used was 12 × 10 mm. Successful device placement was achieved in 60/61 infants (98.4%). Mild aortic obstruction occurred in 2 cases (3.3%), as the device got displaced towards the aorta after release. The device embolized in 2 cases (3.3%). In one it was retrieved by a novel method like fastening the screw in the aorta and was closed with a 4 × 6 ADO II. In the other infant, with a single kidney, died of uremia after device retrieval. Mild left pulmonary artery (LPA) obstruction occurred in one case (1.6%). Four cases (6.6%) had minor vascular complications. The postprocedure weight gain after 3 months was between 2.5 kg ± 250 mg. Device closure of large PDA in infants weighing ≤6 kg with left ventricular failure is challenging but possible, safe and effective. Retrieval of embolized device could be tricky.