Wenbo Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wenbo Zhao has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Di Lu
Science and Technology on Reactor System Design Technology Laboratory, Nuclear Power Institute of China, No. 328, Section 1, Changshun Avenue, Shuangliu County, Chengdu 610213, China
3 shared publications - Lianjie Wang
Science and Technology on Reactor System Design Technology Laboratory, Nuclear Power Institute of China, Chengdu, Sichuan, China
3 shared publications - Ping Yang
Science and Technology on Reactor System Design Technology Laboratory, Nuclear Power Institute of China, No. 328, Section 1, Changshun Avenue, Shuangliu County, Chengdu 610213, China
2 shared publications - Yongqiang Ma
Science and Technology on Reactor System Design Technology Laboratory, Nuclear Power Institute of China, No. 328, Section 1, Changshun Avenue, Shuangliu County, Chengdu 610213, China
1 shared publication
Latest Publications
- 1 January 2019
- Published by ASME International in Journal of Nuclear Engineering and Radiation Science
- Vol. 5 (1)
Coupled Three-Dimensional Neutronics and Thermal-Hydraulics Analysis for SCWR Core Typical Transients
Transient performance of China supercritical water-cooled reactor (SCWR) with the rated electric power of 1000 MWel (CSR1000) core during some typical transients, such as control rod (CR) ejection and uncontrolled CR withdrawal, is analyzed and evaluated with the coupled three-dimensional neutronics and thermal-hydraulics SCWR transient analysis code. The 3D transient analysis shows that the maximum cladding surface temperature (MCST) retains lower than safety criteria 1260 °C during the process of CR ejection accident, and the MCST retains lower than safety criteria 850 °C during the process of uncontrolled CR withdrawal transient. The safety of CSR1000 core can be ensured during the typical transients under the salient fuel temperature and water density reactivity feedback and the essential reactor protection system.
- 1 January 2019
- Published by ASME International in Journal of Nuclear Engineering and Radiation Science
- Vol. 5 (1)
Coupled Three-Dimensional Neutronics and Thermal-Hydraulics Analysis for SCWR Core Typical Transients
Transient performance of China supercritical water-cooled reactor (SCWR) with the rated electric power of 1000 MWel (CSR1000) core during some typical transients, such as control rod (CR) ejection and uncontrolled CR withdrawal, is analyzed and evaluated with the coupled three-dimensional neutronics and thermal-hydraulics SCWR transient analysis code. The 3D transient analysis shows that the maximum cladding surface temperature (MCST) retains lower than safety criteria 1260 °C during the process of CR ejection accident, and the MCST retains lower than safety criteria 850 °C during the process of uncontrolled CR withdrawal transient. The safety of CSR1000 core can be ensured during the typical transients under the salient fuel temperature and water density reactivity feedback and the essential reactor protection system.
- 4 December 2017
- Published by ASME International in Journal of Nuclear Engineering and Radiation Science
- Vol. 4 (1) , 011013
Study on Optimization Design for CSR1000 Core
An optimization design of China supercritical water-cooled reactor (SCWR) with the rated electric power of 1000 MWe (CSR1000) conceptual core is proposed. Steady-state performance of the proposed core is then studied with the SCWR core steady-state analysis code system SNTA. These key parameters such as burnup performance, reactivity control capability, power distribution, maximum fuel cladding temperature, and maximum linear power density are analyzed. The relative coolant flow rate of the second flow path, which is suited with assembly power, is also presented. The study shows that the refueling cycle of CSR1000 core can be extended effectively under the optimization design.
- 4 December 2017
- Published by ASME International in Journal of Nuclear Engineering and Radiation Science
- Vol. 4 (1) , 011013
Study on Optimization Design for CSR1000 Core
An optimization design of China supercritical water-cooled reactor (SCWR) with the rated electric power of 1000 MWe (CSR1000) conceptual core is proposed. Steady-state performance of the proposed core is then studied with the SCWR core steady-state analysis code system SNTA. These key parameters such as burnup performance, reactivity control capability, power distribution, maximum fuel cladding temperature, and maximum linear power density are analyzed. The relative coolant flow rate of the second flow path, which is suited with assembly power, is also presented. The study shows that the refueling cycle of CSR1000 core can be extended effectively under the optimization design.
- 1 March 2017
- Published by ASME International in Journal of Nuclear Engineering and Radiation Science
- Vol. 3 (2) , 021005
Development of SNTA Code System for SCWR Core Steady-State Analysis
A coupled neutronics/thermal-hydraulics (N/T) three-dimensional code system SNTA is developed for supercritical water-cooled reactor (SCWR) core steady-state analysis by modular coupling the improved neutronics nodal methodological code and SCWR thermal-hydraulic subchannel code. The appropriate outer iteration coupling method and self-adaptive relaxation factor are proposed for enhancing convergence, stability, and efficiency of coupled N/T calculation. The steady-state analysis for the CSR1000 core is applied to verify SNTA. The results calculated by SNTA agreed well with those by CASIR and SRAC. SNTA is more efficient than CASIR and SRAC, where the neutronics modules are based on the finite-difference method. The numeric results show that SNTA can be applied to SCWR core steady-state analysis and core concept design.
- 1 March 2017
- Published by ASME International in Journal of Nuclear Engineering and Radiation Science
- Vol. 3 (2) , 021005
Development of SNTA Code System for SCWR Core Steady-State Analysis
A coupled neutronics/thermal-hydraulics (N/T) three-dimensional code system SNTA is developed for supercritical water-cooled reactor (SCWR) core steady-state analysis by modular coupling the improved neutronics nodal methodological code and SCWR thermal-hydraulic subchannel code. The appropriate outer iteration coupling method and self-adaptive relaxation factor are proposed for enhancing convergence, stability, and efficiency of coupled N/T calculation. The steady-state analysis for the CSR1000 core is applied to verify SNTA. The results calculated by SNTA agreed well with those by CASIR and SRAC. SNTA is more efficient than CASIR and SRAC, where the neutronics modules are based on the finite-difference method. The numeric results show that SNTA can be applied to SCWR core steady-state analysis and core concept design.