Clement Richard Boland
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Clement Richard Boland has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Carol A. Durno
Division of Gastroenterology, Hepatology and Nutrition, Department of Pediatrics, The Hospital for Sick Children, Zane Cohen Center, Mount Sinai Hospital, University of Toronto, Ontario, Canada
2 shared publications David A. Johnson
Eastern Virginia Medical School, Norfolk, Virginia
2 shared publicationsDavid Lieberman
Oregon Health and Science University, Portland, Oregon
2 shared publicationsDouglas J. Robertson
VA Medical Center, White River Junction, Vermont; Geisel School of Medicine at Dartmouth, Hanover, New Hampshire
2 shared publicationsDouglas K. Rex
Indiana University School of Medicine, Indianapolis, Indiana
2 shared publicationsFrank M. Giardiello
Johns Hopkins University School of Medicine, Baltimore, Maryland
2 shared publications
Latest Publications
- 1 March 2021
- Published by Springer Nature in Digestive Diseases and Sciences
- Vol. 66 (3) , 855-860
Interval Colorectal Cancer 2006-2015: Novel Observations
Background Screening for colorectal cancer (CRC) with colonoscopy has been credited for the majority of the decline in mortality over the past 40 years. However, colonoscopy is hampered by frequent interval cancers (ICs) occurring within 36 months after the last examination. Risk factors for IC imply that most misses are amenable to improved colonoscopic techniques. This study had two primary objectives: (1) to determine whether the proportion of persons with ICs has declined in association with improved approaches to the quality of colonoscopy and (2) to determine unrecognized causes for missed diagnoses. Methods This is a retrospective, single-center study of persons with CRC having been diagnosed within 6-36 months since the most recent colonoscopy between 2006 and 2015. Participants, ages 50 and 89 years, were evaluated specifically for technical features and findings of the most recent colonoscopy. Results Thirty-nine persons met the inclusion criteria for IC. Mean age was 69.3 years, range 50-86 years, women were 58%, races included 95% Caucasian, 2.5% Asian, and 2.5% African-American, and history of a first-degree relative with CRC was 26%. Symptoms led to the interval diagnosis in 83%, including iron-deficient anemia (38%), bleeding (25%), abdominal/pelvic pain (18%), and change in bowel habit (2.5%). Preexisting neoplasia was present in 72%. The CRC was located in the proximal colon in 51%. Late-stage disease was present in 45%. When compared to persons with an initial diagnosis of screen-detected late-onset CRC, differences were noted for older age, more women, more with a family history of CRC, and more with late-stage disease. The ratio of interval cancers to new cancers ranged between 6 and 11.5%. Findings indicating a "difficult examination" were observed in 14 cases (36%) compared to "easy or no difficulty" examinations in 25 (65%) cases. In a biennial analysis of IC rates between 2006 and 2015, the percentage of IC remained stable between 6 and 11.5%. Conclusions ICs have been stable constituting 6-11.5% of all CRCs. A "difficult examination" was often associated with IC, may be a risk factor for this problem, and may be an important clue warranting further study.
- 1 March 2021
- Published by Springer Nature in Digestive Diseases and Sciences
- Vol. 66 (3) , 855-860
Interval Colorectal Cancer 2006-2015: Novel Observations
Background Screening for colorectal cancer (CRC) with colonoscopy has been credited for the majority of the decline in mortality over the past 40 years. However, colonoscopy is hampered by frequent interval cancers (ICs) occurring within 36 months after the last examination. Risk factors for IC imply that most misses are amenable to improved colonoscopic techniques. This study had two primary objectives: (1) to determine whether the proportion of persons with ICs has declined in association with improved approaches to the quality of colonoscopy and (2) to determine unrecognized causes for missed diagnoses. Methods This is a retrospective, single-center study of persons with CRC having been diagnosed within 6-36 months since the most recent colonoscopy between 2006 and 2015. Participants, ages 50 and 89 years, were evaluated specifically for technical features and findings of the most recent colonoscopy. Results Thirty-nine persons met the inclusion criteria for IC. Mean age was 69.3 years, range 50-86 years, women were 58%, races included 95% Caucasian, 2.5% Asian, and 2.5% African-American, and history of a first-degree relative with CRC was 26%. Symptoms led to the interval diagnosis in 83%, including iron-deficient anemia (38%), bleeding (25%), abdominal/pelvic pain (18%), and change in bowel habit (2.5%). Preexisting neoplasia was present in 72%. The CRC was located in the proximal colon in 51%. Late-stage disease was present in 45%. When compared to persons with an initial diagnosis of screen-detected late-onset CRC, differences were noted for older age, more women, more with a family history of CRC, and more with late-stage disease. The ratio of interval cancers to new cancers ranged between 6 and 11.5%. Findings indicating a "difficult examination" were observed in 14 cases (36%) compared to "easy or no difficulty" examinations in 25 (65%) cases. In a biennial analysis of IC rates between 2006 and 2015, the percentage of IC remained stable between 6 and 11.5%. Conclusions ICs have been stable constituting 6-11.5% of all CRCs. A "difficult examination" was often associated with IC, may be a risk factor for this problem, and may be an important clue warranting further study.
- 6 November 2020
- Published by Springer Nature in Current Treatment Options in Gastroenterology
- Vol. 18 (4) , 589-603
Genetic Testing Use and Expectations in Early Onset Colorectal Cancer
- 6 November 2020
- Published by Springer Nature in Current Treatment Options in Gastroenterology
- Vol. 18 (4) , 589-603
Genetic Testing Use and Expectations in Early Onset Colorectal Cancer
- Open Access
- 12 January 2018
- Published by Springer Nature in Journal of Translational Medicine
- Vol. 16 (1) , 5
Accuracy of four mononucleotide-repeat markers for the identification of DNA mismatch-repair deficiency in solid tumors
To screen tumors with microsatellite instability (MSI) arising due to DNA mismatch repair deficiency (dMMR), a panel of five quasi-monomorphic mononucleotide-repeat markers amplified in a multiplex PCR (Pentaplex) are commonly used. In spite of its several strengths, the pentaplex assay is not robust at detecting the loss of MSH6-deficiency (dMSH6). In order to overcome this challenge, we designed this study to develop and optimize a panel of four quasi-monomorphic mononucleotide-repeat markers (Tetraplex) for identifying solid tumors with dMMR, especially dMSH6. To improve the sensitivity for tumors with dMMR, we established a quasi-monomorphic variant range (QMVR) of 3–4 bp for the four Tetraplex markers. Thereafter, to confirm the accuracy of this assay, we examined 317 colorectal cancer (CRC) specimens, comprising of 105 dMMR [45 MutL homolog (MLH)1-deficient, 45 MutS protein homolog (MSH)2-deficient, and 15 MSH6-deficient tumors] and 212 MMR-proficient (pMMR) tumors as a test set. In addition, we analyzed a cohort of 138 endometrial cancers (EC) by immunohistochemistry to determine MMR protein expression and validation of our new MSI assay. Using the criteria of ≥ 1 unstable markers as MSI-positive tumor, our assay resulted in a sensitivity of 97.1% [95% confidence interval (CI) = 91.9–99.0%] for dMMR, and a specificity of 95.3% (95% CI = 91.5–97.4%) for pMMR CRC specimens. Among the 138 EC specimens, 41 were dMMR according to immunohistochemistry. Herein, our Tetraplex assay detected dMMR tumors with a sensitivity of 92.7% (95% CI = 80.6–97.5%) and a specificity of 97.9% (95% CI = 92.8–99.4%) for pMMR tumors. With respect to tumors with dMSH6, in the CRC-validation set, Tetraplex detected dMSH6 tumors with a sensitivity of 86.7% (13 of 15 dMSH6 CRCs), which was subsequently validated in the EC test set as well (sensitivity, 75.0%; 6 of 8 dMSH6 ECs). Our newly optimized Tetraplex system will help offer a robust and highly sensitive assay for the identification of dMMR in solid tumors.
- 12 January 2018
- Published by Springer Nature in Journal of Translational Medicine
- Vol. 16 (1) , 5
Open AccessAccuracy of four mononucleotide-repeat markers for the identification of DNA mismatch-repair deficiency in solid tumors
To screen tumors with microsatellite instability (MSI) arising due to DNA mismatch repair deficiency (dMMR), a panel of five quasi-monomorphic mononucleotide-repeat markers amplified in a multiplex PCR (Pentaplex) are commonly used. In spite of its several strengths, the pentaplex assay is not robust at detecting the loss of MSH6-deficiency (dMSH6). In order to overcome this challenge, we designed this study to develop and optimize a panel of four quasi-monomorphic mononucleotide-repeat markers (Tetraplex) for identifying solid tumors with dMMR, especially dMSH6. To improve the sensitivity for tumors with dMMR, we established a quasi-monomorphic variant range (QMVR) of 3–4 bp for the four Tetraplex markers. Thereafter, to confirm the accuracy of this assay, we examined 317 colorectal cancer (CRC) specimens, comprising of 105 dMMR [45 MutL homolog (MLH)1-deficient, 45 MutS protein homolog (MSH)2-deficient, and 15 MSH6-deficient tumors] and 212 MMR-proficient (pMMR) tumors as a test set. In addition, we analyzed a cohort of 138 endometrial cancers (EC) by immunohistochemistry to determine MMR protein expression and validation of our new MSI assay. Using the criteria of ≥ 1 unstable markers as MSI-positive tumor, our assay resulted in a sensitivity of 97.1% [95% confidence interval (CI) = 91.9–99.0%] for dMMR, and a specificity of 95.3% (95% CI = 91.5–97.4%) for pMMR CRC specimens. Among the 138 EC specimens, 41 were dMMR according to immunohistochemistry. Herein, our Tetraplex assay detected dMMR tumors with a sensitivity of 92.7% (95% CI = 80.6–97.5%) and a specificity of 97.9% (95% CI = 92.8–99.4%) for pMMR tumors. With respect to tumors with dMSH6, in the CRC-validation set, Tetraplex detected dMSH6 tumors with a sensitivity of 86.7% (13 of 15 dMSH6 CRCs), which was subsequently validated in the EC test set as well (sensitivity, 75.0%; 6 of 8 dMSH6 ECs). Our newly optimized Tetraplex system will help offer a robust and highly sensitive assay for the identification of dMMR in solid tumors.
- 1 May 2017
- Published by Elsevier in Gastroenterology
- Vol. 152 (6) , 1605-1614
Recommendations on Surveillance and Management of Biallelic Mismatch Repair Deficiency (BMMRD) Syndrome: A Consensus Statement by the US Multi-Society Task Force on Colorectal Cancer
- 1 May 2017
- Published by Elsevier in Gastroenterology
- Vol. 152 (6) , 1605-1614
Recommendations on Surveillance and Management of Biallelic Mismatch Repair Deficiency (BMMRD) Syndrome: A Consensus Statement by the US Multi-Society Task Force on Colorectal Cancer
- 1 January 2017
- Published by Elsevier in Gastroenterology
- Vol. 152 (1) , 12-13
“New” Cancer Genes and Inherited Colorectal Cancer Risk: Caveat Emptor
- 1 January 2017
- Published by Elsevier in Gastroenterology
- Vol. 152 (1) , 12-13
“New” Cancer Genes and Inherited Colorectal Cancer Risk: Caveat Emptor