Sylvia Pfensig
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sylvia Pfensig has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Daniela Arbeiter
Institute for Biomedical Engineering, University Medical Center Rostock, Friedrich-Barnewitz-Straße 4, 18119 Rostock, Germany
3 shared publications - Klaus-Peter Schmitz
Institute for ImplantTechnology and Biomaterials e.V. and Institute for Biomedical Engineering, Rostock University Medical Center, Rostock-Warnemuende , Germany
3 shared publications - Niels Grabow
Institute for Biomedical Engineering, Rostock University Medical Center, Friedrich-Barnewitz-Str. 4, 18119 Rostock-Warnemünde, Germany
3 shared publications Klaus-Peter Schmitz
Institute for Biomedical Engineering, Rostock University Medical Center, Rostock- Warnemünde , Germany
2 shared publicationsMichael Stiehm
Institute for ImplantTechnology and Biomaterials e.V., Rostock- Warnemünde , Germany
2 shared publicationsNiels Grabow
Institute for Biomedical Engineering, Rostock University Medical Center, Rostock- Warnemünde , Germany
2 shared publications
Latest Publications
- Open Access
- 1 September 2019
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 5 (1) , 569-572
Development of a constitutive law for numerical simulation of artificial leaflet-structures for transcatheter heart valve prostheses
While the current generation of devices for minimally invasive treatment of severe symptomatic aortic valve stenosis is based on xenogenic leaflet-material, artificial polymeric leaflet-structures represent a promising approach for future improvement of heart valve performance. For enhanced long-term success of polymeric leafletstructures, limitations regarding calcification and durability have to be addressed. The objective of the presented study was the development of a constitutive law representing the material properties of artificial polymeric leaflet-structures of transcatheter heart valve prostheses in numerical simulation to assess the in silico leaflet-performance. Mechanical characterization of cast films and nonwoven specimens of a polycarbonate based silicone elastomer were conducted by means of uniaxial tension and planar shear testing, respectively. For validation purposes, experimental data were compared with the results of finite-element analysis (FEA) using different hyperelastic models. Strain energy function for third-order ogden hyperelastic model achieved the best fit of the non-linear stress-strain behavior of the isotropic polymeric material with the experimental data. It was chosen for further FEA of valve leaflet-performance under physiological pressurization to analyze the suitability of various manufacturing processes for polymeric leafletstructures. Therefore a specific leaflet-design with a wall thickness of 400 μm was used. As a result of FEA, time dependent leaflet-deformation, leaflet coaptation surface area (CSA) and leaflet opening area (LOA) of cast and nonwoven leaflet-structures were calculated. While LOA was comparable for cast and nonwoven leaflet-structures, obtained leaflet-dynamics in a cardiac cycle under physiological pressurization demonstrated crucial influence of the manufacturing process. For nonwoven leafletstructures, an enhanced CSA could be demonstrated in comparison to cast structures. FEA using a validated hyperelastic constitutive law represents a useful tool for in silico performance evaluation of polymeric leaflet-structures under physiological loading and proves the suitability of the polymeric artificial leaflet-material for percutaneous heart valve prostheses.
- 1 September 2019
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 5 (1) , 569-572
Open AccessDevelopment of a constitutive law for numerical simulation of artificial leaflet-structures for transcatheter heart valve prostheses
While the current generation of devices for minimally invasive treatment of severe symptomatic aortic valve stenosis is based on xenogenic leaflet-material, artificial polymeric leaflet-structures represent a promising approach for future improvement of heart valve performance. For enhanced long-term success of polymeric leafletstructures, limitations regarding calcification and durability have to be addressed. The objective of the presented study was the development of a constitutive law representing the material properties of artificial polymeric leaflet-structures of transcatheter heart valve prostheses in numerical simulation to assess the in silico leaflet-performance. Mechanical characterization of cast films and nonwoven specimens of a polycarbonate based silicone elastomer were conducted by means of uniaxial tension and planar shear testing, respectively. For validation purposes, experimental data were compared with the results of finite-element analysis (FEA) using different hyperelastic models. Strain energy function for third-order ogden hyperelastic model achieved the best fit of the non-linear stress-strain behavior of the isotropic polymeric material with the experimental data. It was chosen for further FEA of valve leaflet-performance under physiological pressurization to analyze the suitability of various manufacturing processes for polymeric leafletstructures. Therefore a specific leaflet-design with a wall thickness of 400 μm was used. As a result of FEA, time dependent leaflet-deformation, leaflet coaptation surface area (CSA) and leaflet opening area (LOA) of cast and nonwoven leaflet-structures were calculated. While LOA was comparable for cast and nonwoven leaflet-structures, obtained leaflet-dynamics in a cardiac cycle under physiological pressurization demonstrated crucial influence of the manufacturing process. For nonwoven leafletstructures, an enhanced CSA could be demonstrated in comparison to cast structures. FEA using a validated hyperelastic constitutive law represents a useful tool for in silico performance evaluation of polymeric leaflet-structures under physiological loading and proves the suitability of the polymeric artificial leaflet-material for percutaneous heart valve prostheses.
- Open Access
- 1 September 2018
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 4 (1) , 185-189
Numerical simulation of a transcatheter aortic heart valve under application-related loading
For the treatment of severe symptomatic aortic valve stenosis, minimally invasive heart valve prostheses have more recently become the lifesaving solution for elderly patients with high operational risk and thus, are often implanted in patients with challenging aortic root configuration. A correct prosthesis deployment and stent adaption to the target region is essential to ensure optimal leaflet performance and long-term prosthesis function. The objective of this study was the development of a suitable in silico setup for structural numerical simulation of a transcatheter aortic valve (TAV) in different cases of clinical relevance. A transcatheter valve prosthesis comprising an unpressurized trileaflet heart valve and an adapted stent configuration was designed. An aortic root (AR) model was developed, based on microcomputed tomography of a native healthy specimen. Using the finite-element analysis (FEA), various loading cases including prosthesis biomechanics with valve opening and closing under physiological pressure ratios throughout a cardiac cycle, prosthesis crimping as well as crimping and release into the developed AR model were simulated. Hyperelastic constitutive law for polymeric leaflet material and superelasticity of shape memory alloys for the self-expanding Nitinol stent structure were implemented into the FEA setup. Calculated performance of the valve including the stent structure demonstrated enhanced leaflet opening and closing as a result of stent deformation and redirected loading. Crimping and subsequent release into the AR model as well as the stent adaption to the target region after expansion proved the suitability of the TAV design for percutaneous application. FEA represented a useful tool for numerical simulation of an entire minimally invasive heart valve prosthesis in relevant clinical scenarios.
- 1 September 2018
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 4 (1) , 185-189
Open AccessNumerical simulation of a transcatheter aortic heart valve under application-related loading
For the treatment of severe symptomatic aortic valve stenosis, minimally invasive heart valve prostheses have more recently become the lifesaving solution for elderly patients with high operational risk and thus, are often implanted in patients with challenging aortic root configuration. A correct prosthesis deployment and stent adaption to the target region is essential to ensure optimal leaflet performance and long-term prosthesis function. The objective of this study was the development of a suitable in silico setup for structural numerical simulation of a transcatheter aortic valve (TAV) in different cases of clinical relevance. A transcatheter valve prosthesis comprising an unpressurized trileaflet heart valve and an adapted stent configuration was designed. An aortic root (AR) model was developed, based on microcomputed tomography of a native healthy specimen. Using the finite-element analysis (FEA), various loading cases including prosthesis biomechanics with valve opening and closing under physiological pressure ratios throughout a cardiac cycle, prosthesis crimping as well as crimping and release into the developed AR model were simulated. Hyperelastic constitutive law for polymeric leaflet material and superelasticity of shape memory alloys for the self-expanding Nitinol stent structure were implemented into the FEA setup. Calculated performance of the valve including the stent structure demonstrated enhanced leaflet opening and closing as a result of stent deformation and redirected loading. Crimping and subsequent release into the AR model as well as the stent adaption to the target region after expansion proved the suitability of the TAV design for percutaneous application. FEA represented a useful tool for numerical simulation of an entire minimally invasive heart valve prosthesis in relevant clinical scenarios.
- Open Access
- 7 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 703-706
Cyclic stress-strain behavior of polymeric nonwoven structures for the use as artificial leaflet material for transcatheter heart valve prostheses
Xenogenic leaflet material, bovine and porcine pericardium, is widely used for the fabrication of surgically implanted and transcatheter heart valve prostheses. As a biological material, long term durability of pericardium is limited due to calcification, degeneration and homogeneity. Therefore, polymeric materials represent a promising approach for a next generation of artificial heart valve leaflets with improved durability. Within the current study we analyzed the mechanical performance of polymeric structures based on elastomeric materials. Polymeric cast films were prepared and nonwovens were manufactured in an electrospinning process. Analysis of cyclic stress-strain behavior was performed, using a universal testing machine. The uniaxial cyclic tensile experiments of the elastomeric samples yielded a non-linear elastic response due to viscoelastic behavior with hysteresis. Equilibrium of stress-strain curves was found after a specific number of cycles, for cast films and nonwovens, respectively. In conclusion, preconditioning was found obligatory for the evaluation of the mechanical performance of polymeric materials for the use as artificial leaflet material for heart valve prostheses.
- 7 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 703-706
Open AccessCyclic stress-strain behavior of polymeric nonwoven structures for the use as artificial leaflet material for transcatheter heart valve prostheses
Xenogenic leaflet material, bovine and porcine pericardium, is widely used for the fabrication of surgically implanted and transcatheter heart valve prostheses. As a biological material, long term durability of pericardium is limited due to calcification, degeneration and homogeneity. Therefore, polymeric materials represent a promising approach for a next generation of artificial heart valve leaflets with improved durability. Within the current study we analyzed the mechanical performance of polymeric structures based on elastomeric materials. Polymeric cast films were prepared and nonwovens were manufactured in an electrospinning process. Analysis of cyclic stress-strain behavior was performed, using a universal testing machine. The uniaxial cyclic tensile experiments of the elastomeric samples yielded a non-linear elastic response due to viscoelastic behavior with hysteresis. Equilibrium of stress-strain curves was found after a specific number of cycles, for cast films and nonwovens, respectively. In conclusion, preconditioning was found obligatory for the evaluation of the mechanical performance of polymeric materials for the use as artificial leaflet material for heart valve prostheses.
- Open Access
- 1 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 631-634
Assessment of heart valve performance by finite-element design studies of polymeric leaflet-structures
For the treatment of severe symptomatic aortic valve stenosis, minimally invasive heart valve prostheses are increasingly used, especially for elderly patients. The current generation of devices is based on xenogenic leaflet material, involving limitations with regard to calcification and durability. Artificial polymeric leaflet-structures re-present a promising approach for improvement of valve performance. Within the current work, finite-element ana-lysis (FEA) design studies of polymeric leaflet structures were conducted. Design of an unpressurized and axially-symmetric trileaflet heart valve was developed based on nine parameters. Physiological pressurization in FEA was specified, based on in vitro hydrodynamic testing of a commercially available heart valve prosthesis. Hyper-elastic constitutive law for polymeric leaflet material was implemented based on experimental stress strain curves resulting from uniaxial tensile and planar shear testing. As a result of FEA, time dependent leaflet deformation of the leaflet structure was calculated. Obtained leaflet dynamics were comparable to in vitro performance of the analyzed prosthesis. As a major design parameter, the lunula angle has demonstrated crucial influence on the performance of the polymeric leaflet structures. FEA represented a useful tool for design of improved polymeric leaflet structures for minimally invasive implantable heart valve prostheses.
- 1 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 631-634
Open AccessAssessment of heart valve performance by finite-element design studies of polymeric leaflet-structures
For the treatment of severe symptomatic aortic valve stenosis, minimally invasive heart valve prostheses are increasingly used, especially for elderly patients. The current generation of devices is based on xenogenic leaflet material, involving limitations with regard to calcification and durability. Artificial polymeric leaflet-structures re-present a promising approach for improvement of valve performance. Within the current work, finite-element ana-lysis (FEA) design studies of polymeric leaflet structures were conducted. Design of an unpressurized and axially-symmetric trileaflet heart valve was developed based on nine parameters. Physiological pressurization in FEA was specified, based on in vitro hydrodynamic testing of a commercially available heart valve prosthesis. Hyper-elastic constitutive law for polymeric leaflet material was implemented based on experimental stress strain curves resulting from uniaxial tensile and planar shear testing. As a result of FEA, time dependent leaflet deformation of the leaflet structure was calculated. Obtained leaflet dynamics were comparable to in vitro performance of the analyzed prosthesis. As a major design parameter, the lunula angle has demonstrated crucial influence on the performance of the polymeric leaflet structures. FEA represented a useful tool for design of improved polymeric leaflet structures for minimally invasive implantable heart valve prostheses.
- Open Access
- 1 September 2016
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 2 (1) , 1-4
Synthesis and characterization of PIL/pNIPAAm hybrid hydrogels
In this study, varying amounts of NIPAAm and an ionic liquid (IL), namely 1-vinyl-3-isopropylimidazolium bromide ([ViPrIm]+[Br]−), have been used to synthesize hybrid hydrogels by radical emulsion polymerization. Amounts of 70/30%, 50/50%, 30/70%, 15/85% and 5/95% (wt/wt) of PIL/pNIPAAm were used to produce hybrid hydrogels as well as the parental hydrogels. The adhesive strength was investigated and evaluated for mechanical characterization. Thermal properties of resulting hydrogels have been investigated using differential scanning calorimetry (DSC) in a default heating temperature range (heating rate 10 K min−1). The presence of poly ionic liquids (PIL) in the polymer matrix leads to a moved LCST (lower critical solution temperature) to a higher temperature range for certain hybrid hydrogels PIL/pNIPAAm. While pNIPAAm exhibits an LCST at 33.9 ± 0.3°C, PIL/pNIPAAm 5/95% and PIL/pNIPAAm 15/85% were found to have LCSTs at 37.6 ± 0.9°C and 52 ± 2°C, respectively. This could be used for controlled drug release that goes along with increasing body temperature in response to an implantation caused infection
- 1 September 2016
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 2 (1) , 1-4
Open AccessSynthesis and characterization of PIL/pNIPAAm hybrid hydrogels
In this study, varying amounts of NIPAAm and an ionic liquid (IL), namely 1-vinyl-3-isopropylimidazolium bromide ([ViPrIm]+[Br]−), have been used to synthesize hybrid hydrogels by radical emulsion polymerization. Amounts of 70/30%, 50/50%, 30/70%, 15/85% and 5/95% (wt/wt) of PIL/pNIPAAm were used to produce hybrid hydrogels as well as the parental hydrogels. The adhesive strength was investigated and evaluated for mechanical characterization. Thermal properties of resulting hydrogels have been investigated using differential scanning calorimetry (DSC) in a default heating temperature range (heating rate 10 K min−1). The presence of poly ionic liquids (PIL) in the polymer matrix leads to a moved LCST (lower critical solution temperature) to a higher temperature range for certain hybrid hydrogels PIL/pNIPAAm. While pNIPAAm exhibits an LCST at 33.9 ± 0.3°C, PIL/pNIPAAm 5/95% and PIL/pNIPAAm 15/85% were found to have LCSTs at 37.6 ± 0.9°C and 52 ± 2°C, respectively. This could be used for controlled drug release that goes along with increasing body temperature in response to an implantation caused infection