Thomas Eickner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Thomas Eickner has a total of 78 co-authors. Here are the top co-authors by number of shared publications:
- Niels Grabow
Institute for Biomedical Engineering, Rostock University Medical Center, 18119 Rostock, Germany
11 shared publications - Michael Teske
Institute for Biomedical Engineering, Rostock University Medical Center, Rostock, Germany
9 shared publications Niels Grabow
Institute for Biomedical Engineering, University Medical Center Rostock, Friedrich- Barnewitz-Str. 4, Rostock , Germany
7 shared publications- Hermann Seitz
Microfluidics, Faculty of Mechanical Engineering and Marine Technology, University of Rostock, Justus-von-Liebig Weg 6, 18059 Rostock, Germany
6 shared publications - Robert Mau
Microfluidics, Faculty of Mechanical Engineering and Marine Technology, University of Rostock, Justus-von-Liebig Weg 6, 18059 Rostock, Germany
6 shared publications - Thomas Lenarz
Department of Otolaryngology, Hannover Medical School, Hannover, Germany
6 shared publications
Latest Publications
- Open Access
- 27 March 2026
- Published by MDPI AG in Journal of Composites Science
- Vol. 10 (4) , 179
Feasibility of Solvent-Cast PLLA/Iron Composites for Biomedical Applications
Degradable polymers, such as poly(L-lactide) (PLLA), are widely investigated for biomedical applications, including drug delivery systems and temporary implants. Their functionality can be expanded by incorporating degradable metal microparticles that may influence degradation behaviour and enable additional surface modification strategies. In this study, the feasibility of composites consisting of PLLA and biodegradable iron microparticles was investigated. Composites were fabricated by solvent casting, providing a gentle alternative to thermal processing methods, which often compromise polymer integrity. Composites were evaluated by thermogravimetric analysis, differential scanning calorimetry, scanning electron microscopy (SEM), tensile testing, dynamic mechanical analysis, and X-ray photoelectron spectroscopy (XPS). Incorporation of iron altered thermal behaviour and crystallinity of PLLA, indicating interactions between polymer matrix and dispersed metal phase that may affect degradation kinetics and material stability. While iron addition reduced Young’s modulus, tensile strength, and elongation at break, composites maintained sufficient structural integrity for potential biomedical applications. XPS and SEM confirmed the embedding of particles within the polymer matrix, enabling potential post-processing approaches. In vitro direct contact and eluate tests demonstrated good cell viability, whereas exposure to free iron particles resulted in dose- and time-dependent cytotoxic effects. Overall, the results demonstrate the feasibility of solvent-cast PLLA–iron composites for resorbable biomedical applications.
- 27 March 2026
- Published by MDPI AG in Journal of Composites Science
- Vol. 10 (4) , 179
Open AccessFeasibility of Solvent-Cast PLLA/Iron Composites for Biomedical Applications
Degradable polymers, such as poly(L-lactide) (PLLA), are widely investigated for biomedical applications, including drug delivery systems and temporary implants. Their functionality can be expanded by incorporating degradable metal microparticles that may influence degradation behaviour and enable additional surface modification strategies. In this study, the feasibility of composites consisting of PLLA and biodegradable iron microparticles was investigated. Composites were fabricated by solvent casting, providing a gentle alternative to thermal processing methods, which often compromise polymer integrity. Composites were evaluated by thermogravimetric analysis, differential scanning calorimetry, scanning electron microscopy (SEM), tensile testing, dynamic mechanical analysis, and X-ray photoelectron spectroscopy (XPS). Incorporation of iron altered thermal behaviour and crystallinity of PLLA, indicating interactions between polymer matrix and dispersed metal phase that may affect degradation kinetics and material stability. While iron addition reduced Young’s modulus, tensile strength, and elongation at break, composites maintained sufficient structural integrity for potential biomedical applications. XPS and SEM confirmed the embedding of particles within the polymer matrix, enabling potential post-processing approaches. In vitro direct contact and eluate tests demonstrated good cell viability, whereas exposure to free iron particles resulted in dose- and time-dependent cytotoxic effects. Overall, the results demonstrate the feasibility of solvent-cast PLLA–iron composites for resorbable biomedical applications.
- Open Access
- 1 September 2025
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 11 (1) , 43-46
Enzymatic Degradation of a g-Cyclodextrin- Hyaluronic Acid Copolymer
Postoperative scarring following trabeculectomy, a glaucoma surgery, often leads to failure, necessitating biodegradable drug delivery systems for sustained antifibrotic release. This study explores γ-cyclodextrin/hyaluronic acid (γ- CD/HA) copolymers as potential drug depots, evaluating their degradation kinetics under physiological conditions. Copolymers with 0% and 75% γ-CD were synthesized via base-catalyzed crosslinking with 1,4-butanediol diglycidyl ether (BDDE). Degradation was assessed by incubating samples in Sørensen buffer (pH 7.4) with lysozyme, monitoring mass loss over 14 days. Both systems degraded, yet the 75% CD copolymer exhibited a significantly slower, linear degradation profile compared to the rapidly degrading 0% CD system. Morphological analysis revealed increased swelling in the 75% CD samples, suggesting cleavage of intermolecular crosslinks. Gravimetric analysis indicated a mass loss of approximately 50% for the 75% CD system by day 14. The tunable degradation kinetics of these γ-CD/HA copolymers suggest promise for controlled drug release applications in glaucoma, warranting further investigation into drug loading and release profiles.
- 1 September 2025
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 11 (1) , 43-46
Open AccessEnzymatic Degradation of a g-Cyclodextrin- Hyaluronic Acid Copolymer
Postoperative scarring following trabeculectomy, a glaucoma surgery, often leads to failure, necessitating biodegradable drug delivery systems for sustained antifibrotic release. This study explores γ-cyclodextrin/hyaluronic acid (γ- CD/HA) copolymers as potential drug depots, evaluating their degradation kinetics under physiological conditions. Copolymers with 0% and 75% γ-CD were synthesized via base-catalyzed crosslinking with 1,4-butanediol diglycidyl ether (BDDE). Degradation was assessed by incubating samples in Sørensen buffer (pH 7.4) with lysozyme, monitoring mass loss over 14 days. Both systems degraded, yet the 75% CD copolymer exhibited a significantly slower, linear degradation profile compared to the rapidly degrading 0% CD system. Morphological analysis revealed increased swelling in the 75% CD samples, suggesting cleavage of intermolecular crosslinks. Gravimetric analysis indicated a mass loss of approximately 50% for the 75% CD system by day 14. The tunable degradation kinetics of these γ-CD/HA copolymers suggest promise for controlled drug release applications in glaucoma, warranting further investigation into drug loading and release profiles.
- Open Access
- 1 September 2025
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 11 (1) , 71-74
Degradation Behavior of an Amino Acid- Substituted Polyphosphazene with Triethyl Citrate as Plasticizer
A novel phenylalanine/ valine ethyl ester cosubstituted polyorganophosphazene, incorporating triethyl citrate as plasticizer, is being investigated for its degradability. Films were solvent casted, and allowed to degrade for 4 weeks at an elevated temperature of 50 °C in water and two HEPES buffered solutions with pH values 6.8 and 7.4, respectively. The degradation of the samples in pure water occurred at a significantly accelerated rate compared to the samples incubated in HEPES buffer. Furthermore, based on their influence on degradation, the pH values of the media used were assessed.
- 1 September 2025
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 11 (1) , 71-74
Open AccessDegradation Behavior of an Amino Acid- Substituted Polyphosphazene with Triethyl Citrate as Plasticizer
A novel phenylalanine/ valine ethyl ester cosubstituted polyorganophosphazene, incorporating triethyl citrate as plasticizer, is being investigated for its degradability. Films were solvent casted, and allowed to degrade for 4 weeks at an elevated temperature of 50 °C in water and two HEPES buffered solutions with pH values 6.8 and 7.4, respectively. The degradation of the samples in pure water occurred at a significantly accelerated rate compared to the samples incubated in HEPES buffer. Furthermore, based on their influence on degradation, the pH values of the media used were assessed.
- Open Access
- 18 January 2025
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 16 (1) , 33
Effects of Microstructured and Anti-Inflammatory-Coated Cochlear Implant Electrodes on Fibrous Tissue Growth and Neuronal Survival
Cochlear implants are well established devices for treating severe hearing loss. However, due to the trauma caused by the insertion of the electrode and the subsequent formation of connective tissue, their clinical effectiveness varies. The aim of the current study was to achieve a long-term reduction in connective tissue growth and impedance by combining surface patterns on the electrode array with a poly-L-lactide coating containing 20% diclofenac. Three groups of six guinea pigs each (control, structure, structure with diclofenac in the coating) were implanted for four weeks. The hearing thresholds were measured before implantation and after 28 days, and impedances were monitored over time. After histological preparation, connective tissue growth and spiral ganglion neuron (SGN) survival were quantified. The hearing thresholds and impedances increased over time in all groups, showing no significant differences. The treatment groups showed increased damage in the cochlea, which appeared to be caused by the elevated parts of the microstructures. This seems to be amplified by the trauma model used in the current study. The impedances correlated with connective tissue growth near the electrode contacts. In addition, SGN survival was negatively correlated with the presence of connective tissue, both of which highlight the importance of successfully reducing connective tissue formation after cochlear implantation.
- 18 January 2025
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 16 (1) , 33
Open AccessEffects of Microstructured and Anti-Inflammatory-Coated Cochlear Implant Electrodes on Fibrous Tissue Growth and Neuronal Survival
Cochlear implants are well established devices for treating severe hearing loss. However, due to the trauma caused by the insertion of the electrode and the subsequent formation of connective tissue, their clinical effectiveness varies. The aim of the current study was to achieve a long-term reduction in connective tissue growth and impedance by combining surface patterns on the electrode array with a poly-L-lactide coating containing 20% diclofenac. Three groups of six guinea pigs each (control, structure, structure with diclofenac in the coating) were implanted for four weeks. The hearing thresholds were measured before implantation and after 28 days, and impedances were monitored over time. After histological preparation, connective tissue growth and spiral ganglion neuron (SGN) survival were quantified. The hearing thresholds and impedances increased over time in all groups, showing no significant differences. The treatment groups showed increased damage in the cochlea, which appeared to be caused by the elevated parts of the microstructures. This seems to be amplified by the trauma model used in the current study. The impedances correlated with connective tissue growth near the electrode contacts. In addition, SGN survival was negatively correlated with the presence of connective tissue, both of which highlight the importance of successfully reducing connective tissue formation after cochlear implantation.
- Open Access
- 23 September 2024
- Published by MDPI AG in Pharmaceutics
- Vol. 16 (9) , 1236
Molded Round Window Niche Implant as a Dexamethasone Delivery System in a Cochlear Implant-Trauma Animal Model
Background: Preserving residual hearing after cochlear implant (CI) surgery remains a crucial challenge. The application of dexamethasone (DEX) has been proven to positively affect residual hearing. To deliver DEX in a localized and controlled way, a round window niche implant (RNI), allowing drug diffusion via the round window membrane into the cochlea, may be used. To prove this concept, an RNI for guinea pigs as a CI-trauma model was manufactured by molding and tested for its drug release in vitro and biological effects in vivo. Methods: The RNIs were molded using silicone containing 10% DEX. Release was analyzed over time using high-performance liquid chromatography (HPLC). Fourteen adult guinea pigs were randomly assigned to two groups (CI or CI + RNI group). All animals received a unilateral CI electrode insertion trauma followed by CI insertion. The CI + RNI group was additionally implanted with an RNI containing 10% DEX. Animals were followed up for 4 weeks. Acoustically evoked auditory brainstem response and impedance measurement, micro-computed tomography (µCT) imaging, and histology were performed for evaluation. Results: DEX was released for more than 250 days in vitro, with an initial burst followed by a slower release over time. Comparing the hearing threshold shift (from day 0 to day 28) of the CI and CI + RNI groups, significant differences were observed at 32 and 40 kHz. The impedance shift at basal contacts was lower in the CI + RNI group than in the CI group. Moreover, the fibrosis in the lower basal turn was reduced in the CI + RNI group in contrast to the CI group. Conclusions: The RNI containing 10% DEX has anti-inflammatory potential concerning fibrosis inhibition and has beneficial effects on hearing preservation at high frequencies.
- 23 September 2024
- Published by MDPI AG in Pharmaceutics
- Vol. 16 (9) , 1236
Open AccessMolded Round Window Niche Implant as a Dexamethasone Delivery System in a Cochlear Implant-Trauma Animal Model
Background: Preserving residual hearing after cochlear implant (CI) surgery remains a crucial challenge. The application of dexamethasone (DEX) has been proven to positively affect residual hearing. To deliver DEX in a localized and controlled way, a round window niche implant (RNI), allowing drug diffusion via the round window membrane into the cochlea, may be used. To prove this concept, an RNI for guinea pigs as a CI-trauma model was manufactured by molding and tested for its drug release in vitro and biological effects in vivo. Methods: The RNIs were molded using silicone containing 10% DEX. Release was analyzed over time using high-performance liquid chromatography (HPLC). Fourteen adult guinea pigs were randomly assigned to two groups (CI or CI + RNI group). All animals received a unilateral CI electrode insertion trauma followed by CI insertion. The CI + RNI group was additionally implanted with an RNI containing 10% DEX. Animals were followed up for 4 weeks. Acoustically evoked auditory brainstem response and impedance measurement, micro-computed tomography (µCT) imaging, and histology were performed for evaluation. Results: DEX was released for more than 250 days in vitro, with an initial burst followed by a slower release over time. Comparing the hearing threshold shift (from day 0 to day 28) of the CI and CI + RNI groups, significant differences were observed at 32 and 40 kHz. The impedance shift at basal contacts was lower in the CI + RNI group than in the CI group. Moreover, the fibrosis in the lower basal turn was reduced in the CI + RNI group in contrast to the CI group. Conclusions: The RNI containing 10% DEX has anti-inflammatory potential concerning fibrosis inhibition and has beneficial effects on hearing preservation at high frequencies.
- Open Access
- 1 September 2023
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 9 (1) , 451-454
Manufacture and extraction of PLLA films with incorporated metal ions
For the in vitro examination of the effects on cells and tissues of metal ions derived from implants by wear and corrosion, a system is needed to release metal ions in a controlled and sustained manner. As small concentrations may have an impact on biological systems, a corresponding slow release over a defined period of time is necessary. Here, a manufacturing method of polymeric Poly(L-lactic acid) (PLLA) films with incorporated cobalt ions via dip coating is reported. The establishment of two analytical methods for the detection and quantification of cobalt ions is shown. High performance liquid chromatography enables cobalt quantification over a concentration range of 0.33 μg/mL up to 33 μg/mL in sample solutions. Extraction and detection of cobalt ions from solvent cast PLLA-cobalt-films shows the feasibility of the manufacturing method. Initial biocompatibility tests with manufactured PLLA-cobaltfilms showed no effects on adipose derived primary mesenchymal stem cells (adMSCs).
- 1 September 2023
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 9 (1) , 451-454
Open AccessManufacture and extraction of PLLA films with incorporated metal ions
For the in vitro examination of the effects on cells and tissues of metal ions derived from implants by wear and corrosion, a system is needed to release metal ions in a controlled and sustained manner. As small concentrations may have an impact on biological systems, a corresponding slow release over a defined period of time is necessary. Here, a manufacturing method of polymeric Poly(L-lactic acid) (PLLA) films with incorporated cobalt ions via dip coating is reported. The establishment of two analytical methods for the detection and quantification of cobalt ions is shown. High performance liquid chromatography enables cobalt quantification over a concentration range of 0.33 μg/mL up to 33 μg/mL in sample solutions. Extraction and detection of cobalt ions from solvent cast PLLA-cobalt-films shows the feasibility of the manufacturing method. Initial biocompatibility tests with manufactured PLLA-cobaltfilms showed no effects on adipose derived primary mesenchymal stem cells (adMSCs).
- Open Access
Optimized Gingiva Cell Behavior on Dental Zirconia as a Result of Atmospheric Argon Plasma Activation
Several physico-chemical modifications have been developed to improve cell contact with prosthetic oral implant surfaces. The activation with non-thermal plasmas was one option. Previous studies found that gingiva fibroblasts on laser-microstructured ceramics were hindered in their migration into cavities. However, after argon (Ar) plasma activation, the cells concentrated in and around the niches. The change in surface properties of zirconia and, subsequently, the effect on cell behavior is unclear. In this study, polished zirconia discs were activated by atmospheric pressure Ar plasma using the kINPen®09 jet for 1 min. Surfaces were characterized by scanning electron microscopy, X-ray photoelectron spectroscopy (XPS), and water contact angle. In vitro studies with human gingival fibroblasts (HGF-1) focused on spreading, actin cytoskeleton organization, and calcium ion signaling within 24 h. After Ar plasma activation, surfaces were more hydrophilic. XPS revealed decreased carbon and increased oxygen, zirconia, and yttrium content after Ar plasma. The Ar plasma activation boosted the spreading (2 h), and HGF-1 cells formed strong actin filaments with pronounced lamellipodia. Interestingly, the cells’ calcium ion signaling was also promoted. Therefore, argon plasma activation of zirconia seems to be a valuable tool to bioactivate the surface for optimal surface occupation by cells and active cell signaling.
Open AccessOptimized Gingiva Cell Behavior on Dental Zirconia as a Result of Atmospheric Argon Plasma Activation
Several physico-chemical modifications have been developed to improve cell contact with prosthetic oral implant surfaces. The activation with non-thermal plasmas was one option. Previous studies found that gingiva fibroblasts on laser-microstructured ceramics were hindered in their migration into cavities. However, after argon (Ar) plasma activation, the cells concentrated in and around the niches. The change in surface properties of zirconia and, subsequently, the effect on cell behavior is unclear. In this study, polished zirconia discs were activated by atmospheric pressure Ar plasma using the kINPen®09 jet for 1 min. Surfaces were characterized by scanning electron microscopy, X-ray photoelectron spectroscopy (XPS), and water contact angle. In vitro studies with human gingival fibroblasts (HGF-1) focused on spreading, actin cytoskeleton organization, and calcium ion signaling within 24 h. After Ar plasma activation, surfaces were more hydrophilic. XPS revealed decreased carbon and increased oxygen, zirconia, and yttrium content after Ar plasma. The Ar plasma activation boosted the spreading (2 h), and HGF-1 cells formed strong actin filaments with pronounced lamellipodia. Interestingly, the cells’ calcium ion signaling was also promoted. Therefore, argon plasma activation of zirconia seems to be a valuable tool to bioactivate the surface for optimal surface occupation by cells and active cell signaling.
- Open Access
- 24 May 2023
- Published by MDPI AG in Pharmaceutics
- Vol. 15 (6) , 1584
Micro Injection Molding of Drug-Loaded Round Window Niche Implants for an Animal Model Using 3D-Printed Molds
A novel approach for the long-term medical treatment of the inner ear is the diffusion of drugs through the round window membrane from a patient-individualized, drug-eluting implant, which is inserted in the middle ear. In this study, drug-loaded (10 wt% Dexamethasone) guinea pig round window niche implants (GP-RNIs, ~1.30 mm × 0.95 mm × 0.60 mm) were manufactured with high precision via micro injection molding (µIM, Tmold = 160 °C, crosslinking time of 120 s). Each implant has a handle (~3.00 mm × 1.00 mm × 0.30 mm) that can be used to hold the implant. A medical-grade silicone elastomer was used as implant material. Molds for µIM were 3D printed from a commercially available resin (TG = 84 °C) via a high-resolution DLP process (xy resolution of 32 µm, z resolution of 10 µm, 3D printing time of about 6 h). Drug release, biocompatibility, and bioefficacy of the GP-RNIs were investigated in vitro. GP-RNIs could be successfully produced. The wear of the molds due to thermal stress was observed. However, the molds are suitable for single use in the µIM process. About 10% of the drug load (8.2 ± 0.6 µg) was released after 6 weeks (medium: isotonic saline). The implants showed high biocompatibility over 28 days (lowest cell viability ~80%). Moreover, we found anti-inflammatory effects over 28 days in a TNF-α-reduction test. These results are promising for the development of long-term drug-releasing implants for human inner ear therapy.
- 24 May 2023
- Published by MDPI AG in Pharmaceutics
- Vol. 15 (6) , 1584
Open AccessMicro Injection Molding of Drug-Loaded Round Window Niche Implants for an Animal Model Using 3D-Printed Molds
A novel approach for the long-term medical treatment of the inner ear is the diffusion of drugs through the round window membrane from a patient-individualized, drug-eluting implant, which is inserted in the middle ear. In this study, drug-loaded (10 wt% Dexamethasone) guinea pig round window niche implants (GP-RNIs, ~1.30 mm × 0.95 mm × 0.60 mm) were manufactured with high precision via micro injection molding (µIM, Tmold = 160 °C, crosslinking time of 120 s). Each implant has a handle (~3.00 mm × 1.00 mm × 0.30 mm) that can be used to hold the implant. A medical-grade silicone elastomer was used as implant material. Molds for µIM were 3D printed from a commercially available resin (TG = 84 °C) via a high-resolution DLP process (xy resolution of 32 µm, z resolution of 10 µm, 3D printing time of about 6 h). Drug release, biocompatibility, and bioefficacy of the GP-RNIs were investigated in vitro. GP-RNIs could be successfully produced. The wear of the molds due to thermal stress was observed. However, the molds are suitable for single use in the µIM process. About 10% of the drug load (8.2 ± 0.6 µg) was released after 6 weeks (medium: isotonic saline). The implants showed high biocompatibility over 28 days (lowest cell viability ~80%). Moreover, we found anti-inflammatory effects over 28 days in a TNF-α-reduction test. These results are promising for the development of long-term drug-releasing implants for human inner ear therapy.
- Open Access
- 19 April 2023
- Published by MDPI AG in Preprints.org
Micro Injection Molding of Drug-Loaded Round Window Niche Implants for an Animal Model using 3D Printed Molds
A novel approach for the long-term medical treatment of the inner ear is the diffusion of drugs through the round window membrane from a patient-individualized, drug-eluting implant, which is inserted in the middle ear. In this study, drug-loaded (10 wt% Dexamethasone) guinea pig round window niche implants (GP-RNIs, ~1.30 mm x 0.95 mm x 0.60 mm) were manufactured with high precision via micro injection molding (µIM, Tmold = 160 °C, crosslinking time of 120 s). The medical grade silicone elastomer MED-4244 (NuSil Technology LLC, Radnor, PA, USA) was used. Molds for µIM were 3D printed from a commercially available resin PlasGRAY V2 (Asiga, Alexandria, Australia, TG = 84 °C) via a high-resolution DLP process (xy-resolution of 32 µm, z-resolution of 10 µm, 3D printing time of about 6 h). Drug release, biocompatibility, and bio-efficacy of the GP-RNIs were investigated in vitro. GP-RNIs could be successfully produced. Wear of the molds due to thermal stress was observed. However, the molds are suitable for single use in the µIM process. About 10% of the drug load (8.2 ± 0.6 µg) was released after 6 weeks (medium: isotonic saline). The implants showed high biocompatibility over a time of 28 days (lowest cell viability ~80%). Moreover, we found anti-inflammatory effects over a time of 28 days in a TNF-α-reduction test. These results are promising for the development of long-term drug-releasing implants for human inner ear therapy.
- 19 April 2023
- Published by MDPI AG in Preprints.org
Open AccessMicro Injection Molding of Drug-Loaded Round Window Niche Implants for an Animal Model using 3D Printed Molds
A novel approach for the long-term medical treatment of the inner ear is the diffusion of drugs through the round window membrane from a patient-individualized, drug-eluting implant, which is inserted in the middle ear. In this study, drug-loaded (10 wt% Dexamethasone) guinea pig round window niche implants (GP-RNIs, ~1.30 mm x 0.95 mm x 0.60 mm) were manufactured with high precision via micro injection molding (µIM, Tmold = 160 °C, crosslinking time of 120 s). The medical grade silicone elastomer MED-4244 (NuSil Technology LLC, Radnor, PA, USA) was used. Molds for µIM were 3D printed from a commercially available resin PlasGRAY V2 (Asiga, Alexandria, Australia, TG = 84 °C) via a high-resolution DLP process (xy-resolution of 32 µm, z-resolution of 10 µm, 3D printing time of about 6 h). Drug release, biocompatibility, and bio-efficacy of the GP-RNIs were investigated in vitro. GP-RNIs could be successfully produced. Wear of the molds due to thermal stress was observed. However, the molds are suitable for single use in the µIM process. About 10% of the drug load (8.2 ± 0.6 µg) was released after 6 weeks (medium: isotonic saline). The implants showed high biocompatibility over a time of 28 days (lowest cell viability ~80%). Moreover, we found anti-inflammatory effects over a time of 28 days in a TNF-α-reduction test. These results are promising for the development of long-term drug-releasing implants for human inner ear therapy.
- Open Access
- 22 February 2023
- Published by MDPI AG in Pharmaceutics
- Vol. 15 (3) , 726
Dual Drug Delivery in Cochlear Implants: In Vivo Study of Dexamethasone Combined with Diclofenac or Immunophilin Inhibitor MM284 in Guinea Pigs
Cochlear implants are well established to treat severe hearing impairments. Despite many different approaches to reduce the formation of connective tissue after electrode insertion and to keep electrical impedances low, results are not yet satisfying. Therefore, the aim of the current study was to combine the incorporation of 5% dexamethasone in the silicone body of the electrode array with an additional polymeric coating releasing diclofenac or the immunophilin inhibitor MM284, some anti-inflammatory substances not yet tested in the inner ear. Guinea pigs were implanted for four weeks and hearing thresholds were determined before implantation and after the observation time. Impedances were monitored over time and, finally, connective tissue and the survival of spiral ganglion neurons (SGNs) were quantified. Impedances increased in all groups to a similar extent but this increase was delayed in the groups with an additional release of diclofenac or MM284. Using Poly-L-lactide (PLLA)-coated electrodes, the damage caused during insertion was much higher than without the coating. Only in these groups, connective tissue could extend to the apex of the cochlea. Despite this, numbers of SGNs were only reduced in PLLA and PLLA plus diclofenac groups. Even though the polymeric coating was not flexible enough, MM284 seems to especially have potential for further evaluation in connection with cochlear implantation.
- 22 February 2023
- Published by MDPI AG in Pharmaceutics
- Vol. 15 (3) , 726
Open AccessDual Drug Delivery in Cochlear Implants: In Vivo Study of Dexamethasone Combined with Diclofenac or Immunophilin Inhibitor MM284 in Guinea Pigs
Cochlear implants are well established to treat severe hearing impairments. Despite many different approaches to reduce the formation of connective tissue after electrode insertion and to keep electrical impedances low, results are not yet satisfying. Therefore, the aim of the current study was to combine the incorporation of 5% dexamethasone in the silicone body of the electrode array with an additional polymeric coating releasing diclofenac or the immunophilin inhibitor MM284, some anti-inflammatory substances not yet tested in the inner ear. Guinea pigs were implanted for four weeks and hearing thresholds were determined before implantation and after the observation time. Impedances were monitored over time and, finally, connective tissue and the survival of spiral ganglion neurons (SGNs) were quantified. Impedances increased in all groups to a similar extent but this increase was delayed in the groups with an additional release of diclofenac or MM284. Using Poly-L-lactide (PLLA)-coated electrodes, the damage caused during insertion was much higher than without the coating. Only in these groups, connective tissue could extend to the apex of the cochlea. Despite this, numbers of SGNs were only reduced in PLLA and PLLA plus diclofenac groups. Even though the polymeric coating was not flexible enough, MM284 seems to especially have potential for further evaluation in connection with cochlear implantation.