Dongsheng Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dongsheng Zhao has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
A Christensen
Trescal A/S, Mads Clausens Vej 12, 8600 Silkeborg, Denmark
1 shared publication- David A. Humphreys
National Physical Laboratory, Teddington, UK
1 shared publication F Overney
Federal Institute of Metrology METAS, Lindenweg 50, 3003 Bern-Wabern, Switzerland
1 shared publication- Faisal Ali Mubarak
VSL National Metrology Institute of the Netherlands, Delft, The Netherlands
1 shared publication - Gert Rietveld
University of Twente, Enschede, The Netherlands
1 shared publication J-P Braun
Federal Institute of Metrology METAS, Lindenweg 50, 3003 Bern-Wabern, Switzerland
1 shared publication
Latest Publications
- 21 November 2016
- Published by IOP Publishing in Metrologia
- Vol. 53 (6) , 1384-1394
Traceable measurements of the electrical parameters of solid-state lighting products
In order to perform traceable measurements of the electrical parameters of solid-state lighting (SSL) products, it is necessary to technically adequately define the measurement procedures and to identify the relevant uncertainty sources. The present published written standard for SSL products specifies test conditions, but it lacks an explanation of how adequate these test conditions are. More specifically, both an identification of uncertainty sources and a quantitative uncertainty analysis are absent. This paper fills the related gap in the present written standard. New uncertainty sources with respect to conventional lighting sources are determined and their effects are quantified. It shows that for power measurements, the main uncertainty sources are temperature deviation, power supply voltage distortion, and instability of the SSL product. For current RMS measurements, the influence of bandwidth, shunt resistor, power supply source impedance and ac frequency flatness are significant as well. The measurement uncertainty depends not only on the test equipment but is also a function of the characteristics of the device under test (DUT), for example, current harmonics spectrum and input impedance. Therefore, an online calculation tool is provided to help non-electrical experts. Following our procedures, unrealistic uncertainty estimations, unnecessary procedures and expensive equipment can be prevented.
- 21 November 2016
- Published by IOP Publishing in Metrologia
- Vol. 53 (6) , 1384-1394
Traceable measurements of the electrical parameters of solid-state lighting products
In order to perform traceable measurements of the electrical parameters of solid-state lighting (SSL) products, it is necessary to technically adequately define the measurement procedures and to identify the relevant uncertainty sources. The present published written standard for SSL products specifies test conditions, but it lacks an explanation of how adequate these test conditions are. More specifically, both an identification of uncertainty sources and a quantitative uncertainty analysis are absent. This paper fills the related gap in the present written standard. New uncertainty sources with respect to conventional lighting sources are determined and their effects are quantified. It shows that for power measurements, the main uncertainty sources are temperature deviation, power supply voltage distortion, and instability of the SSL product. For current RMS measurements, the influence of bandwidth, shunt resistor, power supply source impedance and ac frequency flatness are significant as well. The measurement uncertainty depends not only on the test equipment but is also a function of the characteristics of the device under test (DUT), for example, current harmonics spectrum and input impedance. Therefore, an online calculation tool is provided to help non-electrical experts. Following our procedures, unrealistic uncertainty estimations, unnecessary procedures and expensive equipment can be prevented.
- 5 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 64 (2) , 356-365
Principal Component Compression Method for Covariance Matrices Used for Uncertainty Propagation
We investigate a principal component analysis approach for compressing the covariance matrices derived from real-time and sampling oscilloscope measurements. The objective of reducing the data storage requirements to scale proportional to the trace length n rather than n 2 is achieved, making the approach practical for representing results and uncertainties in either the time or frequency domain. Simulation results indicate that the covariance matrices can be represented in a compact form with negligible error. Mathematical manipulation of the compressed matrix can be achieved without the need to reconstruct the full covariance matrix. We have demonstrated compression of data sets containing up to 10000 complex frequency components.
- 5 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 64 (2) , 356-365
Principal Component Compression Method for Covariance Matrices Used for Uncertainty Propagation
We investigate a principal component analysis approach for compressing the covariance matrices derived from real-time and sampling oscilloscope measurements. The objective of reducing the data storage requirements to scale proportional to the trace length n rather than n 2 is achieved, making the approach practical for representing results and uncertainties in either the time or frequency domain. Simulation results indicate that the covariance matrices can be represented in a compact form with negligible error. Mathematical manipulation of the compressed matrix can be achieved without the need to reconstruct the full covariance matrix. We have demonstrated compression of data sets containing up to 10000 complex frequency components.