Alireza Hokmabadi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Alireza Hokmabadi has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Andrew James Swift
School of Medicine & Population Health, The University of Sheffield, Sheffield S10 2TN, UK
2 shared publications - David G. Kiely
School of Medicine & Population Health, The University of Sheffield, Sheffield S10 2TN, UK
2 shared publications - Michael J. Sharkey
School of Medicine & Population Health, The University of Sheffield, Sheffield S10 2TN, UK
2 shared publications - Samer Alabed
School of Medicine & Population Health, The University of Sheffield, Sheffield S10 2TN, UK
2 shared publications - Turki Nasser Alnasser
School of Medicine & Population Health, The University of Sheffield, Sheffield S10 2TN, UK
2 shared publications A. Bayat
Electrical Engineering Department, Engineering Faculty, Imam Khomeini International University, Qazvin, Iran
1 shared publication
Latest Publications
- Open Access
- 8 October 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (19) , 3257
Automated CMR Quantification of Pulmonary Artery Size-Based and Slow-Flow Metrics in Pulmonary Hypertension
Background/Objectives: Pulmonary artery (PA) dilatation and slow-flow are imaging features of pulmonary hypertension (PH), but their quantitative assessment on routine cardiovascular magnetic resonance (CMR) remains limited. This study aimed to develop and evaluate an automated CMR pipeline for quantifying PA size-based and slow-flow metrics from routine white-blood (WB) and black-blood (BB) acquisitions. Methods: A total of 205 CMR acquisitions (106 WB and 99 BB) were used for model development and independent testing. Separate deep learning nnU-Net-based segmentation models were developed for WB and BB acquisitions using a two-stage cascaded framework. Automated measurements included PA volume and PA slow-flow. The trained models were subsequently applied to a larger cohort of 1471 patients using available WB and BB acquisitions to assess automated measurement extraction and agreement with clinical reports. Results: Automated PA volumetric measurements demonstrated excellent agreement with manual reference measurements for both the WB and BB models (ICC 0.94 and 0.93, respectively), with high segmentation accuracy (Dice 0.86 and 0.80, respectively). Automated slow-flow measurements also demonstrated excellent volumetric agreement (ICC 0.94), despite lower spatial overlap (Dice 0.61). Automated slow-flow classification demonstrated 83% agreement with qualitative clinical reporting (κ = 0.58). Conclusions: Automated PA volumetric quantification from routine CMR is feasible. Automated slow-flow quantification showed promising performance but requires validation across scanner vendors and BB acquisition protocols before broader clinical application.
- 8 October 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (19) , 3257
Open AccessAutomated CMR Quantification of Pulmonary Artery Size-Based and Slow-Flow Metrics in Pulmonary Hypertension
Background/Objectives: Pulmonary artery (PA) dilatation and slow-flow are imaging features of pulmonary hypertension (PH), but their quantitative assessment on routine cardiovascular magnetic resonance (CMR) remains limited. This study aimed to develop and evaluate an automated CMR pipeline for quantifying PA size-based and slow-flow metrics from routine white-blood (WB) and black-blood (BB) acquisitions. Methods: A total of 205 CMR acquisitions (106 WB and 99 BB) were used for model development and independent testing. Separate deep learning nnU-Net-based segmentation models were developed for WB and BB acquisitions using a two-stage cascaded framework. Automated measurements included PA volume and PA slow-flow. The trained models were subsequently applied to a larger cohort of 1471 patients using available WB and BB acquisitions to assess automated measurement extraction and agreement with clinical reports. Results: Automated PA volumetric measurements demonstrated excellent agreement with manual reference measurements for both the WB and BB models (ICC 0.94 and 0.93, respectively), with high segmentation accuracy (Dice 0.86 and 0.80, respectively). Automated slow-flow measurements also demonstrated excellent volumetric agreement (ICC 0.94), despite lower spatial overlap (Dice 0.61). Automated slow-flow classification demonstrated 83% agreement with qualitative clinical reporting (κ = 0.58). Conclusions: Automated PA volumetric quantification from routine CMR is feasible. Automated slow-flow quantification showed promising performance but requires validation across scanner vendors and BB acquisition protocols before broader clinical application.
- Open Access
- 24 February 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (5) , 646
A Novel Fully Automated Deep Learning Model for Coronary Artery Calcification Detection on Computed Tomography
Objectives: To assess the diagnostic accuracy of a fully automated deep learning (DL) model for coronary artery segmentation and calcification detection on non-contrast, non-gated CT scans. Methods: A two-stage 3D segmentation pipeline was developed using 42 non-contrast and 27 contrast-enhanced CT scans to identify coronary artery calcifications in the right coronary artery (RCA), left anterior descending artery (LAD), and left circumflex artery (LCX). The model was trained with anatomically refined labels and region-based optimisation to improve structural coherence. Model outputs were visually assessed in a separate cohort of 100 scans by two independent, experienced observers. Segmentation and detection performance were evaluated against manually annotated reference standards using a binary analysis in 473 internal and external scans. Volumetric measurements of calcifications were compared with baseline severity gradings derived from radiologist reports. Results: Most model outputs were rated as excellent in the visual assessment, with good agreement between the outputs and manual reference standards for coronary artery segmentation (κ 0.68 to 0.81) and calcification detection (κ 0.79 to 0.85). The model accurately detected the presence of calcifications in the RCA (κ = 0.82, p < 0.001), LAD (κ = 0.93, p < 0.001), and LCX (κ = 0.82, p < 0.001). The diagnostic accuracy metrics of the model for calcification detection were: sensitivity, 95%; specificity, 98%; positive predictive value, 99%; and negative predictive value, 88%. The volume of calcification yielded by the model correlated with radiologist-reported disease severity, with regression coefficients of 28.3 for RCA, 28.7 for LAD, and 77.5 for LCX. Conclusions: The developed DL model segmented the coronary arteries, detected the presence of calcifications, and predicted disease severity with high accuracy.
- 24 February 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (5) , 646
Open AccessA Novel Fully Automated Deep Learning Model for Coronary Artery Calcification Detection on Computed Tomography
Objectives: To assess the diagnostic accuracy of a fully automated deep learning (DL) model for coronary artery segmentation and calcification detection on non-contrast, non-gated CT scans. Methods: A two-stage 3D segmentation pipeline was developed using 42 non-contrast and 27 contrast-enhanced CT scans to identify coronary artery calcifications in the right coronary artery (RCA), left anterior descending artery (LAD), and left circumflex artery (LCX). The model was trained with anatomically refined labels and region-based optimisation to improve structural coherence. Model outputs were visually assessed in a separate cohort of 100 scans by two independent, experienced observers. Segmentation and detection performance were evaluated against manually annotated reference standards using a binary analysis in 473 internal and external scans. Volumetric measurements of calcifications were compared with baseline severity gradings derived from radiologist reports. Results: Most model outputs were rated as excellent in the visual assessment, with good agreement between the outputs and manual reference standards for coronary artery segmentation (κ 0.68 to 0.81) and calcification detection (κ 0.79 to 0.85). The model accurately detected the presence of calcifications in the RCA (κ = 0.82, p < 0.001), LAD (κ = 0.93, p < 0.001), and LCX (κ = 0.82, p < 0.001). The diagnostic accuracy metrics of the model for calcification detection were: sensitivity, 95%; specificity, 98%; positive predictive value, 99%; and negative predictive value, 88%. The volume of calcification yielded by the model correlated with radiologist-reported disease severity, with regression coefficients of 28.3 for RCA, 28.7 for LAD, and 77.5 for LCX. Conclusions: The developed DL model segmented the coronary arteries, detected the presence of calcifications, and predicted disease severity with high accuracy.
- Open Access
- 2 November 2022
- Published by Elsevier in Medical Image Analysis
- Vol. 83, 102678
DragNet: Learning-based deformable registration for realistic cardiac MR sequence generation from a single frame
- 2 November 2022
- Published by Elsevier in Medical Image Analysis
- Vol. 83, 102678
Open AccessDragNet: Learning-based deformable registration for realistic cardiac MR sequence generation from a single frame
- Open Access
- 1 December 2016
- Vol. 49 (1) , 75-84
A Miniaturized CPW-Fed Tapered Slot Antenna in Lossy Environment for UWB Application in Breast Cancer Detection
- 1 December 2016
- Vol. 49 (1) , 75-84
Open AccessA Miniaturized CPW-Fed Tapered Slot Antenna in Lossy Environment for UWB Application in Breast Cancer Detection
- 21 November 2016
- Published by Cambridge University Press (CUP) in International Journal of Microwave and Wireless Technologies
- Vol. 9 (5) , 1185-1190
A CPW-fed tapered slot antenna with improved time and frequency domain characteristics
In this paper, a miniaturized CPW-fed tapered slot antenna (TSA) with a modified CPW to slot-line transition structure was introduced. An air-bridge and tapered slot edge (TSE) structure was also employed to broaden the transition bandwidth. Through these applied modifications, negative features of the original TSA (limitation of transition) and antipodal Vivaldi antenna (bad cross-polarization) are both removed, while all the positive features remained. Results showed that the proposed structure offered a broad bandwidth of 2.6–20 GHz and also exhibited an appropriate current distribution with high radiation efficiency. The radiation pattern was stable in the working frequency band with good directivity, gain, and low cross-polarization. The proposed antenna structure also presented satisfactory time-domain characteristics. In this study, we confirmed the simulation results through data measurements.
- 21 November 2016
- Published by Cambridge University Press (CUP) in International Journal of Microwave and Wireless Technologies
- Vol. 9 (5) , 1185-1190
A CPW-fed tapered slot antenna with improved time and frequency domain characteristics
In this paper, a miniaturized CPW-fed tapered slot antenna (TSA) with a modified CPW to slot-line transition structure was introduced. An air-bridge and tapered slot edge (TSE) structure was also employed to broaden the transition bandwidth. Through these applied modifications, negative features of the original TSA (limitation of transition) and antipodal Vivaldi antenna (bad cross-polarization) are both removed, while all the positive features remained. Results showed that the proposed structure offered a broad bandwidth of 2.6–20 GHz and also exhibited an appropriate current distribution with high radiation efficiency. The radiation pattern was stable in the working frequency band with good directivity, gain, and low cross-polarization. The proposed antenna structure also presented satisfactory time-domain characteristics. In this study, we confirmed the simulation results through data measurements.