DLDan Li

Dan Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dan Li has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Novel Method for Source Tracking of Chemical Gas Leakage: Outlier Mutation Optimization Algorithm

    by Zhiyu Xia, Zhengyi Xu, Dan Li, Jianming Wei

    Chemical industrial parks, which act as critical infrastructures in many cities, need to be responsive to chemical gas leakage accidents. Once a chemical gas leakage accident occurs, risks of poisoning, fire, and explosion will follow. In order to meet the primary emergency response demands in chemical gas leakage accidents, source tracking technology of chemical gas leakage has been proposed and evolved. This paper proposes a novel method, Outlier Mutation Optimization (OMO) algorithm, aimed to quickly and accurately track the source of chemical gas leakage. The OMO algorithm introduces a random walk exploration mode and, based on Swarm Intelligence (SI), increases the probability of individual mutation. Compared with other optimization algorithms, the OMO algorithm has the advantages of a wider exploration range and more convergence modes. In the algorithm test session, a series of chemical gas leakage accident application examples with random parameters are first assumed based on the Gaussian plume model; next, the qualitative experiments and analysis of the OMO algorithm are conducted, based on the application example. The test results show that the OMO algorithm with default parameters has superior comprehensive performance, including the extremely high average calculation accuracy: the optimal value, which represents the error between the final objective function value obtained by the optimization algorithm and the ideal value, reaches 2.464e-15 when the number of sensors is 16; 2.356e-13 when the number of sensors is 9; and 5.694e-23 when the number of sensors is 4. There is a satisfactory calculation time: 12.743 s/50 times when the number of sensors is 16; 10.304 s/50 times when the number of sensors is 9; and 8.644 s/50 times when the number of sensors is 4. The analysis of the OMO algorithm’s characteristic parameters proves the flexibility and robustness of this method. In addition, compared with other algorithms, the OMO algorithm can obtain an excellent leakage source tracing result in the application examples of 16, 9 and 4 sensors, and the accuracy exceeds the direct search algorithm, evolutionary algorithm, and other swarm intelligence algorithms.


  • Open Access

    A Robust Dynamic Heart-Rate Detection Algorithm Framework During Intense Physical Activities Using Photoplethysmographic Signals

    by Jiajia Song, Dan Li, Xiaoyuan Ma, Guowei Teng, Jianming Wei

    Dynamic accurate heart-rate (HR) estimation using a photoplethysmogram (PPG) during intense physical activities is always challenging due to corruption by motion artifacts (MAs). It is difficult to reconstruct a clean signal and extract HR from contaminated PPG. This paper proposes a robust HR-estimation algorithm framework that uses one-channel PPG and tri-axis acceleration data to reconstruct the PPG and calculate the HR based on features of the PPG and spectral analysis. Firstly, the signal is judged by the presence of MAs. Then, the spectral peaks corresponding to acceleration data are filtered from the periodogram of the PPG when MAs exist. Different signal-processing methods are applied based on the amount of remaining PPG spectral peaks. The main MA-removal algorithm (NFEEMD) includes the repeated single-notch filter and ensemble empirical mode decomposition. Finally, HR calibration is designed to ensure the accuracy of HR tracking. The NFEEMD algorithm was performed on the 23 datasets from the 2015 IEEE Signal Processing Cup Database. The average estimation errors were 1.12 BPM (12 training datasets), 2.63 BPM (10 testing datasets) and 1.87 BPM (all 23 datasets), respectively. The Pearson correlation was 0.992. The experiment results illustrate that the proposed algorithm is not only suitable for HR estimation during continuous activities, like slow running (13 training datasets), but also for intense physical activities with acceleration, like arm exercise (10 testing datasets).