Reza Hadjiaghaie Vafaie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Reza Hadjiaghaie Vafaie has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
E. Poorreza
Faculty of Electrical Engineering, Sahand University of Technology, Tabriz, Iran
2 shared publicationsA. Moradpour
Microelectronics Research Lab, Electrical Engineering Department, Sahand University of Technology, Tabriz, Iran
1 shared publication- Abolfazl Moradpour1 shared publication
- Amir Mosavi
Óbuda University
1 shared publication - Ardashir Mohammadzadeh
Faculty of Engineering, Department of Electrical and Electronics Engineering, Sakarya University, Sakarya, Turkey
1 shared publication - Elnaz Poorreza
Department of Electrical Engineering, Aras Branch, Islamic Azad University, Jolfa, Iran
1 shared publication
Latest Publications
- 1 December 2025
- Published by Pleiades Publishing Ltd in Russian Journal of Physical Chemistry B
- Vol. 19 (6) , 1448-1457
Electrokinetic-Induced Isolation of Circulating Tumor Cells in a Microfluidic Device under the Influence of External Electric Field: A Computational Study
Cell-based cancer analysis constitutes a significant investigatory methodology for monitoring the progression of cancer across different stages by quantifying the density of circulating tumor cells (CTCs) present in the bloodstream. Among the array of contemporary microfluidic techniques, dielectrophoresis (DEP), recognized as an electrokinetic phenomenon and a label-free detection modality, is particularly esteemed by researchers in the field. In the present study, a microfluidic device featuring semi-circular electrodes operating at a low voltage of approximately 1.5 V is proposed with the objective of isolating CTCs from various subtypes of white blood cells (WBCs). The employment of a low voltage is essential for maintaining the viability of biological cells, an aspect of paramount importance in medical applications. Through computational simulation with the finite element method, the electric potential profiles, the paths of the cell particles, and the DEP forces on cells were elucidated.
- 1 December 2025
- Published by Pleiades Publishing Ltd in Russian Journal of Physical Chemistry B
- Vol. 19 (6) , 1448-1457
Electrokinetic-Induced Isolation of Circulating Tumor Cells in a Microfluidic Device under the Influence of External Electric Field: A Computational Study
Cell-based cancer analysis constitutes a significant investigatory methodology for monitoring the progression of cancer across different stages by quantifying the density of circulating tumor cells (CTCs) present in the bloodstream. Among the array of contemporary microfluidic techniques, dielectrophoresis (DEP), recognized as an electrokinetic phenomenon and a label-free detection modality, is particularly esteemed by researchers in the field. In the present study, a microfluidic device featuring semi-circular electrodes operating at a low voltage of approximately 1.5 V is proposed with the objective of isolating CTCs from various subtypes of white blood cells (WBCs). The employment of a low voltage is essential for maintaining the viability of biological cells, an aspect of paramount importance in medical applications. Through computational simulation with the finite element method, the electric potential profiles, the paths of the cell particles, and the DEP forces on cells were elucidated.
- Open Access
- 7 November 2025
- Published by MDPI AG in Biomimetics
- Vol. 10 (11) , 753
A Bionic Sensing Platform for Cell Separation: Simulation of a Dielectrophoretic Microfluidic Device That Leverages Dielectric Fingerprints
Cancers are diseases described by the irregular spread of cells that have developed invasive features, enabling them to invade adjacent tissues. The specific diagnosis and effective management of oncological treatments depend on the timely detection of circulating tumor cells (CTCs) in a patient’s bloodstream. One of the most promising approaches to CTC separation from blood fractions involves the dielectrophoresis (DEP) technique. This research presents a new DEP-based bionic system designed for MDA-MB-231 breast cancer cell isolation from white blood cell (WBC) subtypes with a viable approach to cell viability. This work leverages the principle that every cell type possesses a unique dielectric fingerprint. This dielectrophoresis microfluidic device is designed to act as a scanner, reading these fingerprints to achieve a continuous, label-free separation of cancer cells from blood components with a high efficiency. In the proposed system that consists of three different stages, the first stage allows for separating B-lymphocytes and Monocytes from Granulocytes and MDA-MB-231 cells. The separation of B-lymphocytes from Monocytes occurs in the second step, while the last step concerns the separation of Granulocytes and MDA-MB-231 cells. In the analysis, x-y graphs of the electric potentials, velocity fields, pressure distributions, and cellular DEP forces applied to the cells, as well as the resulting particle paths, are provided. The model predicts that the system operates with a separation efficiency of nearly 92%. This work focuses on an investigation of the impact of electrode potentials, the velocity of cells, the number of electrodes, the width of the channel, and the output angles on enhancing the separation efficiency of particles.
- 7 November 2025
- Published by MDPI AG in Biomimetics
- Vol. 10 (11) , 753
Open AccessA Bionic Sensing Platform for Cell Separation: Simulation of a Dielectrophoretic Microfluidic Device That Leverages Dielectric Fingerprints
Cancers are diseases described by the irregular spread of cells that have developed invasive features, enabling them to invade adjacent tissues. The specific diagnosis and effective management of oncological treatments depend on the timely detection of circulating tumor cells (CTCs) in a patient’s bloodstream. One of the most promising approaches to CTC separation from blood fractions involves the dielectrophoresis (DEP) technique. This research presents a new DEP-based bionic system designed for MDA-MB-231 breast cancer cell isolation from white blood cell (WBC) subtypes with a viable approach to cell viability. This work leverages the principle that every cell type possesses a unique dielectric fingerprint. This dielectrophoresis microfluidic device is designed to act as a scanner, reading these fingerprints to achieve a continuous, label-free separation of cancer cells from blood components with a high efficiency. In the proposed system that consists of three different stages, the first stage allows for separating B-lymphocytes and Monocytes from Granulocytes and MDA-MB-231 cells. The separation of B-lymphocytes from Monocytes occurs in the second step, while the last step concerns the separation of Granulocytes and MDA-MB-231 cells. In the analysis, x-y graphs of the electric potentials, velocity fields, pressure distributions, and cellular DEP forces applied to the cells, as well as the resulting particle paths, are provided. The model predicts that the system operates with a separation efficiency of nearly 92%. This work focuses on an investigation of the impact of electrode potentials, the velocity of cells, the number of electrodes, the width of the channel, and the output angles on enhancing the separation efficiency of particles.
- 5 January 2025
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 101, 990-997
Design and simulation of a Pd-functionalized cantilever for hydrogen detection
- 5 January 2025
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 101, 990-997
Design and simulation of a Pd-functionalized cantilever for hydrogen detection
- 1 December 2023
- Published by Pleiades Publishing Ltd in Theoretical Foundations of Chemical Engineering
- Vol. 57 (6) , 1552-1571
A Comparative Investigation of an Argon Dielectric Barrier Discharge Reactor under the Variation of Plasma Conditions for Optimization of Power Deposition
Gas discharges in the plasma atmosphere are known to consist of a collection of different particles, mainly electrons, ions, neutral atoms, and molecules. The present need is to characterize the plasmas and optimization of the designed plasma system under variable conditions. In this work, a time-dependent, one-dimensional simulation of an optimized DBD device, driven by a sinusoidal alternating high voltage, in argon gas is demonstrated. First of all, a DBD device with two electrodes, covered by the dielectric and with the variable discharge gap was assumed, and the discharge parameters were simulated versus time across the plasma gap. A comparison between the results is carried out. In the second part, with a fixed gap that was obtained from previous section, when the dielectric thickness changed, the plasma parameters were simulated. In the third case, with a fixed discharge gap and dielectric thickness, the plate diameters were varied and the best diameter was selected to deliver the best power deposition. Finally, the operating frequency and voltage were varied and the optimized values were obtained. Time-dependent and 1D profiles of the electric field, electron density, electron temperature, ion current density, electron current density, plasma, total current, and power deposition are demonstrated.
- 1 December 2023
- Published by Pleiades Publishing Ltd in Theoretical Foundations of Chemical Engineering
- Vol. 57 (6) , 1552-1571
A Comparative Investigation of an Argon Dielectric Barrier Discharge Reactor under the Variation of Plasma Conditions for Optimization of Power Deposition
Gas discharges in the plasma atmosphere are known to consist of a collection of different particles, mainly electrons, ions, neutral atoms, and molecules. The present need is to characterize the plasmas and optimization of the designed plasma system under variable conditions. In this work, a time-dependent, one-dimensional simulation of an optimized DBD device, driven by a sinusoidal alternating high voltage, in argon gas is demonstrated. First of all, a DBD device with two electrodes, covered by the dielectric and with the variable discharge gap was assumed, and the discharge parameters were simulated versus time across the plasma gap. A comparison between the results is carried out. In the second part, with a fixed gap that was obtained from previous section, when the dielectric thickness changed, the plasma parameters were simulated. In the third case, with a fixed discharge gap and dielectric thickness, the plate diameters were varied and the best diameter was selected to deliver the best power deposition. Finally, the operating frequency and voltage were varied and the optimized values were obtained. Time-dependent and 1D profiles of the electric field, electron density, electron temperature, ion current density, electron current density, plasma, total current, and power deposition are demonstrated.
- 10 August 2023
- Published by Pleiades Publishing Ltd in Colloid Journal
- Vol. 85 (4) , 629-649
An Experimental Study of a Magnetic Liquid Marble and a Novel Scheme for Improving the Sensitivity of a Liquid Marble-Based Accelerometer
Due to the interfacial energy minimization phenomenon, rolling a liquid droplet on a solid powder bed consisting of hydrophobic micro-nano sized particles results in particle adhesion onto the droplet surface. These interesting flexible formations (known as dry waters or liquid marble) have attracted a great deal of attention in surface science. After the formation of a magnetic liquid marble with a radius of about 1.1 mm, reversible opening and closing of magnetic nanoparticle shell by the permanent magnet is conducted in the experimental part of this study. In the simulation part of our investigation, which is the novelty of our work, by modeling a liquid marble by a droplet with an elastic shell, the effect of gravitational force on the marble and its motion on a curved substrate were simulated by the finite element method. A novel scheme for increasing the sensitivity of a liquid marble-based accelerometer is presented. The presented scheme for this investigation consists of a liquid marble placed on a curved surface which is manipulated magnetically by placing a permanent magnet above the curved surface. The produced magnetic force deforms the marble shape by opposing its weight, therefore causes the marble to get approximately spherical rather than puddle shaped form.
- 10 August 2023
- Published by Pleiades Publishing Ltd in Colloid Journal
- Vol. 85 (4) , 629-649
An Experimental Study of a Magnetic Liquid Marble and a Novel Scheme for Improving the Sensitivity of a Liquid Marble-Based Accelerometer
Due to the interfacial energy minimization phenomenon, rolling a liquid droplet on a solid powder bed consisting of hydrophobic micro-nano sized particles results in particle adhesion onto the droplet surface. These interesting flexible formations (known as dry waters or liquid marble) have attracted a great deal of attention in surface science. After the formation of a magnetic liquid marble with a radius of about 1.1 mm, reversible opening and closing of magnetic nanoparticle shell by the permanent magnet is conducted in the experimental part of this study. In the simulation part of our investigation, which is the novelty of our work, by modeling a liquid marble by a droplet with an elastic shell, the effect of gravitational force on the marble and its motion on a curved substrate were simulated by the finite element method. A novel scheme for increasing the sensitivity of a liquid marble-based accelerometer is presented. The presented scheme for this investigation consists of a liquid marble placed on a curved surface which is manipulated magnetically by placing a permanent magnet above the curved surface. The produced magnetic force deforms the marble shape by opposing its weight, therefore causes the marble to get approximately spherical rather than puddle shaped form.
- Open Access
- 7 June 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (12) , 9225
Using a Photoacoustic Cell for Spectroscopy of Toxic Air Pollutants including CO2, SO2 and NO Gases
Due to the rise in global temperature and climate change, the detection of CO2, SO2 and NO pollutants is important in smart cities. In this paper, an H-shaped photoacoustic cell is utilized for the detection of low-concentration gases. The geometry of the cell is miniaturized and designed with specific parameters in order to increase its efficiency and performance. The designed cell eliminates problems such as bulkiness and cost, which prevent the use of sensors in detecting greenhouse gases. The simplicity of the design expands the application rate of the cell in practice. In order to consider the viscosity and thermal effects, the cell is formulized by fully linearized Navier–Stokes equations, and various parameters, such as acoustic pressure, frequency response, sound speed (sound velocity) and quality factor, are investigated for the mentioned gases. The performance of the system is frequency-based, and the target gases can be detected by using a microelectromechanical resonator as a pressure sensor. Quality factor analysis expresses that CO2, SO2 and NO gases have quality factors of 27.84, 33.62 and 33.32, respectively. The performance of the cell in the resonance state can be expressed by the linear correlation between the results. The background noise generated in the photoacoustic research has been removed by miniaturization due to the obtained resonance, and the proposed cell provides a proper signal-to-noise ratio. The results of the proposed system represent the increase in the quality factor, which reduces the losses and thus increases the sensitivity of the system in the study of greenhouse gases.
- 7 June 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (12) , 9225
Open AccessUsing a Photoacoustic Cell for Spectroscopy of Toxic Air Pollutants including CO2, SO2 and NO Gases
Due to the rise in global temperature and climate change, the detection of CO2, SO2 and NO pollutants is important in smart cities. In this paper, an H-shaped photoacoustic cell is utilized for the detection of low-concentration gases. The geometry of the cell is miniaturized and designed with specific parameters in order to increase its efficiency and performance. The designed cell eliminates problems such as bulkiness and cost, which prevent the use of sensors in detecting greenhouse gases. The simplicity of the design expands the application rate of the cell in practice. In order to consider the viscosity and thermal effects, the cell is formulized by fully linearized Navier–Stokes equations, and various parameters, such as acoustic pressure, frequency response, sound speed (sound velocity) and quality factor, are investigated for the mentioned gases. The performance of the system is frequency-based, and the target gases can be detected by using a microelectromechanical resonator as a pressure sensor. Quality factor analysis expresses that CO2, SO2 and NO gases have quality factors of 27.84, 33.62 and 33.32, respectively. The performance of the cell in the resonance state can be expressed by the linear correlation between the results. The background noise generated in the photoacoustic research has been removed by miniaturization due to the obtained resonance, and the proposed cell provides a proper signal-to-noise ratio. The results of the proposed system represent the increase in the quality factor, which reduces the losses and thus increases the sensitivity of the system in the study of greenhouse gases.
- Open Access
Photoacoustic Detection of Pollutants Emitted by Transportation System for Use in Automotive Industry
In photoacoustic spectroscopy, the signal is inversely proportional to the resonant cell volume. Photoacoustic spectroscopy (PAS) is an absorption spectroscopy technique that is suitable for detecting gases at low concentrations. This desirable feature has created a growing interest in miniaturizing PA cells in recent years. In this paper, a simulation of a miniaturized H-type photoacoustic cell consisting of two buffer holes and a resonator was performed in order to detect CO, NH3, NO, and CH4 pollutants. These gases are the main components of the air pollutants that are produced by the automotive industry. The linear forms of the continuity, Navier–Stokes equations, and the energy equation were solved using the finite element method in a gaseous medium. The generated pressure could be measured by a MEMS sensor. Photoacoustic spectroscopy has proven to be a sensitive method for detecting pollutant gases. The objectives of the measurements were: determining the proper position of the pressure gauge sensor; measuring the frequency response; measuring the frequency response changes at different temperatures; studying the local velocity at the resonant frequency; and calculating the quality factor. The acoustic quality coefficient, acoustic response (pressure), local velocity, frequency response, and the effect of different temperatures on the frequency response were investigated. A frequency response measurement represents the fact that different gases have different resonance frequencies, for which CO and NO gases had values of 23.131 kHz and 23.329 kHz, respectively. The difference between these gases was 200 Hz. NH3 and CH4 gases with values of 21.206 kHz and 21.106 kHz were separable with a difference of 100 Hz. In addition, CO and NO gases had a difference of 2000 Hz compared to NH3 and CH4, which indicates the characteristic fingerprint of the designed cell in the detection of different gases. Better access to high-frequency acoustic signals was the goal of the presented model in this paper.
Open AccessPhotoacoustic Detection of Pollutants Emitted by Transportation System for Use in Automotive Industry
In photoacoustic spectroscopy, the signal is inversely proportional to the resonant cell volume. Photoacoustic spectroscopy (PAS) is an absorption spectroscopy technique that is suitable for detecting gases at low concentrations. This desirable feature has created a growing interest in miniaturizing PA cells in recent years. In this paper, a simulation of a miniaturized H-type photoacoustic cell consisting of two buffer holes and a resonator was performed in order to detect CO, NH3, NO, and CH4 pollutants. These gases are the main components of the air pollutants that are produced by the automotive industry. The linear forms of the continuity, Navier–Stokes equations, and the energy equation were solved using the finite element method in a gaseous medium. The generated pressure could be measured by a MEMS sensor. Photoacoustic spectroscopy has proven to be a sensitive method for detecting pollutant gases. The objectives of the measurements were: determining the proper position of the pressure gauge sensor; measuring the frequency response; measuring the frequency response changes at different temperatures; studying the local velocity at the resonant frequency; and calculating the quality factor. The acoustic quality coefficient, acoustic response (pressure), local velocity, frequency response, and the effect of different temperatures on the frequency response were investigated. A frequency response measurement represents the fact that different gases have different resonance frequencies, for which CO and NO gases had values of 23.131 kHz and 23.329 kHz, respectively. The difference between these gases was 200 Hz. NH3 and CH4 gases with values of 21.206 kHz and 21.106 kHz were separable with a difference of 100 Hz. In addition, CO and NO gases had a difference of 2000 Hz compared to NH3 and CH4, which indicates the characteristic fingerprint of the designed cell in the detection of different gases. Better access to high-frequency acoustic signals was the goal of the presented model in this paper.
- 7 January 2019
- Published by Emerald Publishing in COMPEL - The international journal for computation and mathematics in electrical and electronic engineering
- Vol. 38 (1) , 119-137
Numerical simulation of EWOD on a printed circuit board for cleanroom-less digital fluidic manufacturing applications
Purpose: Digital microfluidic devices have been demonstrated to have great potential for a wide range of applications. These devices need expensive photolithography process and clean room facilities, while printed circuit board (PCB) technology provides high configurability and at low cost. This study aims to investigate the mechanism of electrowetting-on-a-dielectric (EWOD) on PCB by solving the multiphysics interaction between fluid droplet and electric field. The performance of system will be improved by inducing an efficient electric field inside the droplet. Design/methodology/approach: To induce an electric field inside the droplet on a PCB and change the initial contact angle, the mechanism of EWOD is studied based on energy minimization method and a set of simulations are carried out by considering multiphysics interaction between the fluid droplet and external electric field. The performance of EWOD on a PCB system is investigated using different electrode structures. Findings: Surface tension plays an efficient role in smaller sizes and can be used to move and control a fluid droplet on a surface by changing the interfacial surface tension. EWOD on a PCB system is studied. and it revealed that any change in electric field affects the droplet contact angle and as a result droplet deformation and movement. The electrode pattern is an important parameter which could change the electric potential distribution inside the droplet. Array of electrodes with square, zigzag interdigitated and crescent shapes are studied to enhance the EWOD force on a PCB substrate. Based on the results, the radial shape of the crescent electrodes keeps almost the same actuated contact line, applies uniform force on the droplet periphery and prevents the droplet from large deformation. A droplet velocity of 0.6 mm/s is achieved by exciting the crescent electrodes at 315 V. Furthermore, the behavior of system is characterized for process parameters such as actuation voltage, dielectric constant of insulator layer, fluidic material properties and the resultant velocity and contact angle. The study of contact angle distribution and droplet motion revealed that it is helpful to generate EWOD mechanism on a PCB which does not need more complicated fabrication processes. Originality/value: The ability to handle and manipulate the droplets is very important for chemistry on-chip analysis such as immunoassay chips. Furthermore, a PCB-based electrowetting-on-dielectric device is of high interest because it does not need cleanroom facilities and avoids additional high-cost fabrication processes. In the present research, the EWOD mechanism is studied on a PCB by using different electrode patterns.
- 7 January 2019
- Published by Emerald Publishing in COMPEL - The international journal for computation and mathematics in electrical and electronic engineering
- Vol. 38 (1) , 119-137
Numerical simulation of EWOD on a printed circuit board for cleanroom-less digital fluidic manufacturing applications
Purpose: Digital microfluidic devices have been demonstrated to have great potential for a wide range of applications. These devices need expensive photolithography process and clean room facilities, while printed circuit board (PCB) technology provides high configurability and at low cost. This study aims to investigate the mechanism of electrowetting-on-a-dielectric (EWOD) on PCB by solving the multiphysics interaction between fluid droplet and electric field. The performance of system will be improved by inducing an efficient electric field inside the droplet. Design/methodology/approach: To induce an electric field inside the droplet on a PCB and change the initial contact angle, the mechanism of EWOD is studied based on energy minimization method and a set of simulations are carried out by considering multiphysics interaction between the fluid droplet and external electric field. The performance of EWOD on a PCB system is investigated using different electrode structures. Findings: Surface tension plays an efficient role in smaller sizes and can be used to move and control a fluid droplet on a surface by changing the interfacial surface tension. EWOD on a PCB system is studied. and it revealed that any change in electric field affects the droplet contact angle and as a result droplet deformation and movement. The electrode pattern is an important parameter which could change the electric potential distribution inside the droplet. Array of electrodes with square, zigzag interdigitated and crescent shapes are studied to enhance the EWOD force on a PCB substrate. Based on the results, the radial shape of the crescent electrodes keeps almost the same actuated contact line, applies uniform force on the droplet periphery and prevents the droplet from large deformation. A droplet velocity of 0.6 mm/s is achieved by exciting the crescent electrodes at 315 V. Furthermore, the behavior of system is characterized for process parameters such as actuation voltage, dielectric constant of insulator layer, fluidic material properties and the resultant velocity and contact angle. The study of contact angle distribution and droplet motion revealed that it is helpful to generate EWOD mechanism on a PCB which does not need more complicated fabrication processes. Originality/value: The ability to handle and manipulate the droplets is very important for chemistry on-chip analysis such as immunoassay chips. Furthermore, a PCB-based electrowetting-on-dielectric device is of high interest because it does not need cleanroom facilities and avoids additional high-cost fabrication processes. In the present research, the EWOD mechanism is studied on a PCB by using different electrode patterns.
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 308-312
Theoretical and experimental study of high conductive fluid and electric field interaction inside a microchannel
Design of on-Chip fluidic devices such as micromixer, micropump, concentrator and so on are particularly troublesome, due to viscose effects in micro-scale. We have studied both the experimental and theoretical effect of AC electrokinetic mechanism for manipulation of high conductive fluids. Fluid velocity control was numerically studied by FE-Anlysis to solve the electrical, thermal and fluid mechanic multiphysic coupled equations. Based on the studies, the efficiency of ac electrothermal phenomena increases theoretically by increasing the ionic strength of fluid medium. From experimental point of view, the Phosphate Buffered Saline is prepared as carrier fluid with different electrical conductivities and then seeded with 1 μm sized fluorescent particles to investigate fluid motion inside a microchannel. An array of asymmetric electrode pairs were structured on a silicon substrate to generate non-uniform electric field and induce efficient temperature gradient. As a result, the fluid motion starts to occur from the narrow electrodes towards the wide electrodes. Experimental results confirm that the proposed system is highly efficient for conductive mediums and the efficiency improves by increasing both the applied electric field amplitude and frequency. But, electrochemical reaction and electrode degradation is observed at very high conductive mediums (above 0.7 S/m). The frequency behaviour of working fluid is measured by impedance analyser.
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 308-312
Theoretical and experimental study of high conductive fluid and electric field interaction inside a microchannel
Design of on-Chip fluidic devices such as micromixer, micropump, concentrator and so on are particularly troublesome, due to viscose effects in micro-scale. We have studied both the experimental and theoretical effect of AC electrokinetic mechanism for manipulation of high conductive fluids. Fluid velocity control was numerically studied by FE-Anlysis to solve the electrical, thermal and fluid mechanic multiphysic coupled equations. Based on the studies, the efficiency of ac electrothermal phenomena increases theoretically by increasing the ionic strength of fluid medium. From experimental point of view, the Phosphate Buffered Saline is prepared as carrier fluid with different electrical conductivities and then seeded with 1 μm sized fluorescent particles to investigate fluid motion inside a microchannel. An array of asymmetric electrode pairs were structured on a silicon substrate to generate non-uniform electric field and induce efficient temperature gradient. As a result, the fluid motion starts to occur from the narrow electrodes towards the wide electrodes. Experimental results confirm that the proposed system is highly efficient for conductive mediums and the efficiency improves by increasing both the applied electric field amplitude and frequency. But, electrochemical reaction and electrode degradation is observed at very high conductive mediums (above 0.7 S/m). The frequency behaviour of working fluid is measured by impedance analyser.
- 21 November 2016
- Published by Springer Nature in Microsystem Technologies
- Vol. 23 (5) , 1495-1507
AC electrothermal actuation mechanism for on-chip mixing of high ionic strength fluids
- 21 November 2016
- Published by Springer Nature in Microsystem Technologies
- Vol. 23 (5) , 1495-1507
AC electrothermal actuation mechanism for on-chip mixing of high ionic strength fluids