Samuel Mesihää
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Samuel Mesihää has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Ilpo Rasanen
Finnish Institute for Health and Welfare, Forensic Toxicology Unit, PO Box 30, FI-00271, Helsinki, Finland
6 shared publications- Ilkka Ojanperä
Forensic Toxicology Unit, Finnish Institute for Health and Welfare (THL) , Helsinki, FI-00271
5 shared publications Anna Pelander
Forensic Toxicology Unit, National Institute for Health and Welfare, PO Box 30, Helsinki, Finland
3 shared publicationsRaimo A. Ketola
Forensic Toxicology Unit, National Institute for Health and Welfare, PO Box 30, 00271, Helsinki, Finland
2 shared publicationsIlkka Ojanperä
University of Helsinki, Department of Forensic Medicine, P.O. Box 40, FI-00014 University of Helsinki, Finland; National Institute for Health and Welfare, Forensic Toxicology Unit, Helsinki, Finland
1 shared publication
Latest Publications
- 17 August 2019
- Published by Oxford University Press (OUP) in Journal of Analytical Toxicology
- Vol. 44 (2) , 163-172
Quantitative Estimation of 38 Illicit Psychostimulants in Blood by GC-APCI-QTOFMS with Nitrogen Chemiluminescence Detection Based on Three External Calibrators
A method was developed for quantitative estimation of illicit psychostimulants in blood, with an emphasis on new psychoactive substances, based on gas chromatography nitrogen chemiluminescence detection coupled with atmospheric pressure chemical ionization quadrupole time-of-flight mass spectrometry (GC-NCD-APCI-QTOFMS). Quantitative estimation relied on the NCD’s N-equimolar response to nitrogen, using amphetamine, 3,4-methylenedioxymethamphetamine (MDMA) and methylenedioxypyrovalerone as external calibrators for prim-, sec- and tert- amines, respectively. After spiking with 38 stimulants at 3 concentration levels, the donor blood samples were submitted to liquid–liquid extraction at a basic pH followed by acylation with trifluoroacetic anhydride. All but 3 psychostimulants could be analyzed with a limit of quantification (LOQ) of 0.05 mg/L. At LOQ, the coefficient of variation (CV) values for between-day accuracy was 62.3–143.3% (mean, 93.5%; median, 88.5%) and precision 6.6–22.4% (mean, 15.8%; median, 16.1%). In addition, 11 post-mortem blood samples, containing 0.08–2.4 mg/L of amphetamine (n = 5), methamphetamine (n = 4) or MDMA (n = 4), were analyzed by the GC-NCD-APCI-QTOFMS method, and the results were compared with an established electron ionization GC–MS method with appropriate calibration. The agreement between the 2 methods was 62.5–117.3%. Regarding identification, the APCI source permitted detection of the intact precursor ion, or the respective acylation product, for all of the measured compounds. The GC-NCD-APCI-QTOFMS method developed here enables instant quantitative estimation of illicit psychostimulants in blood at reasonable accuracy, without the necessity of possessing the true reference standards for each analyte.
- 17 August 2019
- Published by Oxford University Press (OUP) in Journal of Analytical Toxicology
- Vol. 44 (2) , 163-172
Quantitative Estimation of 38 Illicit Psychostimulants in Blood by GC-APCI-QTOFMS with Nitrogen Chemiluminescence Detection Based on Three External Calibrators
A method was developed for quantitative estimation of illicit psychostimulants in blood, with an emphasis on new psychoactive substances, based on gas chromatography nitrogen chemiluminescence detection coupled with atmospheric pressure chemical ionization quadrupole time-of-flight mass spectrometry (GC-NCD-APCI-QTOFMS). Quantitative estimation relied on the NCD’s N-equimolar response to nitrogen, using amphetamine, 3,4-methylenedioxymethamphetamine (MDMA) and methylenedioxypyrovalerone as external calibrators for prim-, sec- and tert- amines, respectively. After spiking with 38 stimulants at 3 concentration levels, the donor blood samples were submitted to liquid–liquid extraction at a basic pH followed by acylation with trifluoroacetic anhydride. All but 3 psychostimulants could be analyzed with a limit of quantification (LOQ) of 0.05 mg/L. At LOQ, the coefficient of variation (CV) values for between-day accuracy was 62.3–143.3% (mean, 93.5%; median, 88.5%) and precision 6.6–22.4% (mean, 15.8%; median, 16.1%). In addition, 11 post-mortem blood samples, containing 0.08–2.4 mg/L of amphetamine (n = 5), methamphetamine (n = 4) or MDMA (n = 4), were analyzed by the GC-NCD-APCI-QTOFMS method, and the results were compared with an established electron ionization GC–MS method with appropriate calibration. The agreement between the 2 methods was 62.5–117.3%. Regarding identification, the APCI source permitted detection of the intact precursor ion, or the respective acylation product, for all of the measured compounds. The GC-NCD-APCI-QTOFMS method developed here enables instant quantitative estimation of illicit psychostimulants in blood at reasonable accuracy, without the necessity of possessing the true reference standards for each analyte.
- 22 December 2016
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 409 (8) , 2007-2013
Development of a GC-APCI-QTOFMS library for new psychoactive substances and comparison to a commercial ESI library
Gas chromatography coupled to atmospheric pressure chemical ionization quadrupole time-of-flight mass spectrometry (GC-APCI-QTOFMS) was evaluated for the identification of new psychoactive substances (NPS). An in-house high mass resolution GC-APCI-QTOFMS test library was developed for 29 nitrogen-containing drugs belonging mostly to synthetic stimulants. The library was based on 12 intra-day measurements of each compound at three different collision energies, 10, 20 and 40 eV. The in-house library mass spectra were compared to mass spectra from a commercial library constructed by liquid chromatography-electrospray ionization (LC-ESI) QTOFMS. The reversed library search scores between the in-house GC-APCI library and the commercial LC-ESI library were compared once a week during a 5-week period by using data measured by GC-APCI-QTOFMS. The protonated molecule was found for all drugs in the full scan mode, and the drugs were successfully identified by both libraries in the targeted MS/MS mode. The GC-APCI library score averaged over all collision energies was as high as 94.4/100 with a high repeatability, while the LC-ESI library score was also high (89.7/100) with a repeatability only slightly worse. These results highlight the merits of GC-APCI-QTOFMS in the analysis of NPS even in situations where the reference standards are not immediately available, taking advantage of the accurate mass measurement of the protonated molecule and product ions, and comparison to existing soft-ionization mass spectral libraries.
- 22 December 2016
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 409 (8) , 2007-2013
Development of a GC-APCI-QTOFMS library for new psychoactive substances and comparison to a commercial ESI library
Gas chromatography coupled to atmospheric pressure chemical ionization quadrupole time-of-flight mass spectrometry (GC-APCI-QTOFMS) was evaluated for the identification of new psychoactive substances (NPS). An in-house high mass resolution GC-APCI-QTOFMS test library was developed for 29 nitrogen-containing drugs belonging mostly to synthetic stimulants. The library was based on 12 intra-day measurements of each compound at three different collision energies, 10, 20 and 40 eV. The in-house library mass spectra were compared to mass spectra from a commercial library constructed by liquid chromatography-electrospray ionization (LC-ESI) QTOFMS. The reversed library search scores between the in-house GC-APCI library and the commercial LC-ESI library were compared once a week during a 5-week period by using data measured by GC-APCI-QTOFMS. The protonated molecule was found for all drugs in the full scan mode, and the drugs were successfully identified by both libraries in the targeted MS/MS mode. The GC-APCI library score averaged over all collision energies was as high as 94.4/100 with a high repeatability, while the LC-ESI library score was also high (89.7/100) with a repeatability only slightly worse. These results highlight the merits of GC-APCI-QTOFMS in the analysis of NPS even in situations where the reference standards are not immediately available, taking advantage of the accurate mass measurement of the protonated molecule and product ions, and comparison to existing soft-ionization mass spectral libraries.