    Controlling Morphology and Physio-Chemical Properties of Stimulus-Responsive Polyurethane Foams by Altering Chemical Blowing Agent Content

    by Sayyeda Marziya Hasan, Tyler Touchet, Aishwarya Jayadeep, Duncan J. Maitland

    Amorphous shape memory polymer foams are currently used as components in vascular occlusion medical devices such as the IMPEDE and IMPEDE-FX Embolization Plugs. Body temperature and moisture-driven actuation of the polymeric foam is necessary for vessel occlusion and the rate of expansion is a function of physio-chemical material properties. In this study, concentrations of the chemical blowing agent for the foam were altered and the resulting effects on morphology, thermal and chemical properties, and actuation rates were studied. Lower concentration of chemical blowing agent yielded foams with thick foam struts due to less bubble formation during the foaming process. Foams with thicker struts also had high tensile modulus and lower strain at break values compared to the foams made with higher blowing agent concentration. Additionally, less blowing agent resulted in foams with a lower glass transition temperature due to less urea formation during the foaming reaction. This exploratory study provides an approach to control thermo-mechanical foam properties and morphology by tuning concentrations of a foaming additive. This work aims to broaden the applications of shape memory polymer foams for medical use.


  • Open Access

    Influence of Aging, Sterilization, and Composition on the Degradation of Polyurethane Foams

    by Sam T Briggs, Mary Beth B Monroe, Mark A Wierzbicki, Sayyeda Marziya Hasan, Duncan J Maitland

    Shape memory polymers (SMPs) are highly attractive materials for medical devices. Specifically, SMP foams are currently being used as embolic devices in peripheral and cerebral vascular applications. To ensure the proper function and safety of these materials in their intended applications, it is important to understand how processing treatments, such as aging, sterilization, and foam composition can influence their degradation. Here, SMP foams were treated with industry relevant processing parameters, and the influence on degradation was observed via gravimetric, chemical, and morphological studies. Accelerated thermal aging was shown to have an influence on material degradation rate in real time oxidative studies. Sterilization was performed via Electron beam (E-beam) irradiation at the high and low dosages commonly used in industry and had no significant influence on foam degradation profiles. These findings help inform appropriate treatment of SMP foam embolic devices to ensure their safety and efficacy.


  • Open Access

    Shape Memory Polymer Foams Synthesized Using Glycerol and Hexanetriol for Enhanced Degradation Resistance

    by Sayyeda Marziya Hasan, Grace K. Fletcher, Mary Beth Browning Monroe, Mark A. Wierzbicki, Landon D. Nash, Duncan J. Maitland

    Shape memory polymer foams have been used in a wide range of medical applications, including, but not limited to, vessel occlusion and aneurysm treatment. This unique polymer system has been proven to shape-fill a void, which makes it useful for occlusion applications. While the shape memory polymer foam has superior performance and healing outcomes compared to its leading competitors, some device applications may benefit from longer material degradation times, or degradation-resistant formulations with increased fibrous encapsulation. In this study, biostable shape memory polymer foams were synthesized, and their physical and chemical properties were characterized as an initial evaluation of feasibility for vascular occlusion applications. After characterizing their shape memory behavior in an aqueous environment, degradation of this polymer system was studied in vitro using accelerated oxidative and hydrolytic solutions. Results indicated that the foams did not lose mass under oxidative or hydrolytic conditions, and they maintained high shape recovery in aqueous in vitro models. These degradation-resistant systems have potential for use in vascular occlusion and other wound healing applications that benefit from permanent, space-filling shape memory behavior.


  • Shape memory polyurethane‐urea foams with improved toughness

    by Alexandra D. Easley, Mary Beth Browning Monroe, Sayyeda M. Hasan, Andrew C. Weems, Jane Frederick, Duncan J. Maitland

    Current vascular aneurysm treatments often require either highly invasive strategy to surgically occlude an aneurysm or endovascular occlusion via metal coils. While endovascular coils are safer, they have limited efficacy. Endovascular coils that are integrated with shape memory polymer (SMP) foams have the potential to improve occlusion and reduce coil risks; however, the mechanical performance and limited homogeneity of SMP foams can hinder their effective use. To address this issue, SMP foams are synthesized using the monomer diethanolamine (DEA) in place of triethanolamine (TEA) to provide improved mechanical properties for medical device applications. Mechanical testing and micro‐fracture analysis were performed on DEA and TEA foams. DEA foams show improved toughness and reduced micro‐fractures compared to the control. This work presents the utility of DEA in SMP synthesis to enable the potential production of safer aneurysm treatment. © 2018 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2019, 136, 47268.


  • Effects of Sterilization on Shape Memory Polyurethane Embolic Foam Devices

    by Rachael Muschalek, Landon Nash, Ryan Jones, Sayyeda M. Hasan, Brandis K. Keller, Mary Beth B. Monroe, Duncan J. Maitland

    Polyurethane shape memory polymer (SMP) foams have been developed for various embolic medical devices due to their unique properties in minimally invasive biomedical applications. These polyurethane materials can be stored in a secondary shape, from which they can recover their primary shape after exposure to an external stimulus, such as heat and water exposure. Tailored actuation temperatures of SMPs provide benefits for minimally invasive biomedical applications, but incur significant challenges for SMP-based medical device sterilization. Most sterilization methods require high temperatures or high humidity to effectively reduce the bioburden of the device, but the environment must be tightly controlled after device fabrication. Here, two probable sterilization methods (nontraditional ethylene oxide (ntEtO) gas sterilization and electron beam irradiation) are investigated for SMP medical devices. Thermal characterization of the sterilized foams indicated that ntEtO gas sterilization significantly decreased the glass transition temperature. Further material characterization was undertaken on the electron beam (ebeam) sterilized samples, which indicated minimal changes to the thermomechanical integrity of the bulk foam and to the device functionality.


  • Particulate Release From Nanoparticle-Loaded Shape Memory Polymer Foams

    by Adam L. Nathan, Grace K. Fletcher, Mary Beth B. Monroe, Wonjun Hwang, Scott M. Herting, Sayyeda M. Hasan, Brandis K. Keller, Duncan J. Maitland

    Highly porous, open-celled shape memory polymer (SMP) foams are being developed for a number of vascular occlusion devices. Applications include abdominal aortic and neurovascular aneurysm or peripheral vascular occlusion. A major concern with implanting these high surface area materials in the vasculature is the potential to generate unacceptable particulate burden, in terms of number, size, and composition. This study demonstrates that particulate numbers and sizes in SMP foams are in compliance with limits stated by the most relevant standard and guidance documents. Particulates were quantified in SMP foams as made, postreticulation, and after incorporating nanoparticles intended to increase material toughness and improve radiopacity. When concentrated particulate treatments were administered to fibroblasts, they exhibited high cell viability (100%). These results demonstrate that the SMP foams do not induce an unacceptable level of risk to potential vascular occlusion devices due to particulate generation.


  • A shape memory foam composite with enhanced fluid uptake and bactericidal properties as a hemostatic agent

    by T.L. Landsman, T. Touchet, S.M. Hasan, C. Smith, B. Russell, J. Rivera, D.J. Maitland, E. Cosgriff-Hernandez


  • Design and verification of a shape memory polymer peripheral occlusion device

    by Todd L. Landsman, Ruth L. Bush, Alan Glowczwski, John Horn, Staci L. Jessen, Ethan Ungchusri, Katelin Diguette, Harrison R. Smith, Sayyeda M. Hasan, Daniel Nash, et al.


  • Development of siloxane-based amphiphiles as cell stabilizers for porous shape memory polymer systems

    by Sayyeda M. Hasan, Alexandra D. Easley, Mary Beth Browning Monroe, Duncan J. Maitland


  • Cold Plasma Reticulation of Shape Memory Embolic Tissue Scaffolds

    by Landon D. Nash, Nicole C. Docherty, Mary Beth B. Monroe, Kendal P. Ezell, James K. Carrow, Sayyeda M. Hasan, Akhilesh K. Gaharwar, Duncan J. Maitland

    Polyurethane shape memory polymer (SMP) foams are proposed for use as thrombogenic scaffolds to improve the treatment of vascular defects, such as cerebral aneurysms. However, gas blown SMP foams inherently have membranes between pores, which can limit their performance as embolic tissue scaffolds. Reticulation, or the removal of membranes between adjacent foam pores, is advantageous for improving device performance by increasing blood permeability and cellular infiltration. This work characterizes the effects of cold gas plasma reticulation processes on bulk polyurethane SMP films and foams. Plasma‐induced changes on material properties are characterized using scanning electron microscopy, uniaxial tensile testing, goniometry, and free strain recovery experiments. Device specific performance is characterized in terms of permeability, platelet attachment, and cell–material interactions. Overall, plasma reticulated SMP scaffolds show promise as embolic tissue scaffolds due to increased bulk permeability, retained thrombogenicity, and favorable cell–material interactions. image