Lien T. N. Truong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lien T. N. Truong has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Kasper Eersels
Sensor Engineering Department, Faculty of Science and Engineering, Maastricht University, P.O. Box 616, Maastricht 6200 MD, The Netherlands
1 shared publication Mun’delanji C. Vestergaard
Department of Bioscience and Biotechnology, Kagoshima University, Kagoshima, Japan
1 shared publicationNguyen Quoc Hao
1 shared publication- Patrick Wagner
Laboratory for Soft Matter and Biophysics, Department of Physics and Astronomy, KU Leuven, Celestijnenlaan 200 D, 3001 Leuven, Belgium
1 shared publication Phi Van Toan
1 shared publication- Tin Phan Nguy
Vietnam-Korea Institute of Science and Technology, Hoa Lac Hi-Tech Park, Research and Development Zone, Hanoi 100000, Vietnam
1 shared publication
Latest Publications
- 1 March 2019
- Published by IOP Publishing in Advances in Natural Sciences: Nanoscience and Nanotechnology
- Vol. 10 (1) , 015015
Using AuNPs-modified screen-printed electrode in the development of molecularly imprinted polymer for artificial bioreceptor fabrication to improve biosensor sensitivity for 17 β -estradiol detection
In this work, we reported on the development of a sensor platform for the detection of 17 β -Estradiol (E2). The artificial receptors for targets were fabricated on gold nanoparticles (AuNPs)-modified screen-printed carbon ink electrode. This is an applicable technical solution to overcome main limitations of current membrane molecularly imprinted polymer (MIP) technology. The AuNPs layer will increase specific area of electrode, hence increasing number of imprinted analyte molecules to polymer membrane. Especially, the harmonic distribution of AuNPs on the electrode helps to generate a single oriented monomer layer on the electrode. In turn, this layer helps to generate a highly homogeneous membrane of polymer with thickness of only several single layers to easily remove imprinted molecules from polymer matrix to form highly specific cavities, thus increasing the efficiency of the fabrication of artificial MIP bioreceptors. Our fabricated sensors showed the capability of detection limit (LOD) of 2 fM. The sensor also demonstrated reduced cost (cost of carbon ink printed electrode but can use as gold ink printed electrode), detection platform simplicity, and high reproducibility.
- 1 March 2019
- Published by IOP Publishing in Advances in Natural Sciences: Nanoscience and Nanotechnology
- Vol. 10 (1) , 015015
Using AuNPs-modified screen-printed electrode in the development of molecularly imprinted polymer for artificial bioreceptor fabrication to improve biosensor sensitivity for 17 β -estradiol detection
In this work, we reported on the development of a sensor platform for the detection of 17 β -Estradiol (E2). The artificial receptors for targets were fabricated on gold nanoparticles (AuNPs)-modified screen-printed carbon ink electrode. This is an applicable technical solution to overcome main limitations of current membrane molecularly imprinted polymer (MIP) technology. The AuNPs layer will increase specific area of electrode, hence increasing number of imprinted analyte molecules to polymer membrane. Especially, the harmonic distribution of AuNPs on the electrode helps to generate a single oriented monomer layer on the electrode. In turn, this layer helps to generate a highly homogeneous membrane of polymer with thickness of only several single layers to easily remove imprinted molecules from polymer matrix to form highly specific cavities, thus increasing the efficiency of the fabrication of artificial MIP bioreceptors. Our fabricated sensors showed the capability of detection limit (LOD) of 2 fM. The sensor also demonstrated reduced cost (cost of carbon ink printed electrode but can use as gold ink printed electrode), detection platform simplicity, and high reproducibility.
- 13 December 2016
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 46 (6) , 3542-3552
Anisotropic In Situ-Coated AuNPs on Screen-Printed Carbon Surface for Enhanced Prostate-Specific Antigen Impedimetric Aptasensor
- 13 December 2016
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 46 (6) , 3542-3552
Anisotropic In Situ-Coated AuNPs on Screen-Printed Carbon Surface for Enhanced Prostate-Specific Antigen Impedimetric Aptasensor