Angela Zanni
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Angela Zanni has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Erica Leoni
Department of Biomedical and Neuromotor Sciences, Unit of Hygiene, Public Health and Medical Statistics, University of Bologna, via San Giacomo 12, 40126, Bologna, Italy
3 shared publications - Laura Dallolio
Department of Biomedical and Neuromotor Science, Alma Mater Studiorum, University of Bologna, 40126 Bologna, Italy
3 shared publications - Patrizia Farruggia
Local Health Authority of Bologna.
3 shared publications - Alessandra Raggi
Department of Biomedical and Neuromotor Sciences, Unit of Hygiene, Public Health and Medical Statistics, University of Bologna, via S. Giacomo 12, 40126, Bologna, Italy
2 shared publications - Magda Mazzetti
Unit of Hygiene, Control of Healthcare Associated Infections, Bologna Local Health Authority, “Bellaria” Hospital, via Altura 3, 40139, Bologna, Italy
2 shared publications - Alessandra Orsi
Unit of Hygiene and Quality of Residential Services, Local Health Authority of Bologna, Bellaria Hospital, via Altura 3, 40139 Bologna, Italy
1 shared publication
Latest Publications
- Open Access
- 19 November 2018
- Published by Springer Nature in BMC Infectious Diseases
- Vol. 18 (1) , 1-7
ATP bioluminescence assay for evaluating cleaning practices in operating theatres: applicability and limitations
Environmental cleaning practice plays an important role in reducing microbial contamination in hospital surfaces and contributes to prevent Healthcare Associated Infections. Adenosine Triphosphate (ATP) bioluminescence assay is a commonly used method for assessing environmental cleanliness on healthcare surfaces. This study tested the feasibility of using ATP-bioluminescence assay for evaluating the efficiency of cleaning procedures in the operating theatre settings, comparing the ATP-bioluminescence test with the traditional culture method. The surfaces of 10 operating rooms of two public hospitals (140 samples in total) were examined “at rest”, in two moments of the same daily session: before the first scheduled operation (Pre), and before the second, after a clean environment was re-established (Post). Surface contamination was assessed using the cultural method to detect Total Viable Counts (TVC36°C) and ATP-bioluminescence assay (RLU). The examined surfaces presented very low TVCs (geometric means: 1.8 CFU/plate; IC95%: 1.6–2.0), always compliant with the relative reference standards. No statistical correlation was found between ATP values and TVCs. However, considering the results in terms of general evaluation of hygienic quality of surfaces, the two methods were consistent in identifying the most contaminated areas (Hospital A > Hospital B; Pre > Post; most contaminated surfaces: scialytic lamp). Furthermore, the ATP mean values showed a progressive increase from surfaces with TVC = 0 to surfaces with TVC > 15 CFU/plate. Although not an alternative to cultural methods, the ATP-bioluminescence-assay can be a useful tool to measure the efficiency of cleaning procedures also in environments with very low microbial counts. Each health facility should identify appropriate reference values, depending on the devices used and on the basis of the analysis of the data collected through spatial and temporal sampling series. By providing a rapid feedback, the ATP-assay helps to increase the awareness of operators and allows immediate action to be taken in critical situations.
- 19 November 2018
- Published by Springer Nature in BMC Infectious Diseases
- Vol. 18 (1) , 1-7
Open AccessATP bioluminescence assay for evaluating cleaning practices in operating theatres: applicability and limitations
Environmental cleaning practice plays an important role in reducing microbial contamination in hospital surfaces and contributes to prevent Healthcare Associated Infections. Adenosine Triphosphate (ATP) bioluminescence assay is a commonly used method for assessing environmental cleanliness on healthcare surfaces. This study tested the feasibility of using ATP-bioluminescence assay for evaluating the efficiency of cleaning procedures in the operating theatre settings, comparing the ATP-bioluminescence test with the traditional culture method. The surfaces of 10 operating rooms of two public hospitals (140 samples in total) were examined “at rest”, in two moments of the same daily session: before the first scheduled operation (Pre), and before the second, after a clean environment was re-established (Post). Surface contamination was assessed using the cultural method to detect Total Viable Counts (TVC36°C) and ATP-bioluminescence assay (RLU). The examined surfaces presented very low TVCs (geometric means: 1.8 CFU/plate; IC95%: 1.6–2.0), always compliant with the relative reference standards. No statistical correlation was found between ATP values and TVCs. However, considering the results in terms of general evaluation of hygienic quality of surfaces, the two methods were consistent in identifying the most contaminated areas (Hospital A > Hospital B; Pre > Post; most contaminated surfaces: scialytic lamp). Furthermore, the ATP mean values showed a progressive increase from surfaces with TVC = 0 to surfaces with TVC > 15 CFU/plate. Although not an alternative to cultural methods, the ATP-bioluminescence-assay can be a useful tool to measure the efficiency of cleaning procedures also in environments with very low microbial counts. Each health facility should identify appropriate reference values, depending on the devices used and on the basis of the analysis of the data collected through spatial and temporal sampling series. By providing a rapid feedback, the ATP-assay helps to increase the awareness of operators and allows immediate action to be taken in critical situations.
- Open Access
- 28 December 2017
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 15 (1) , 46
Surveillance of Environmental and Procedural Measures of Infection Control in the Operating Theatre Setting
The microbiological contamination of operating theatres and the lack of adherence to best practices by surgical staff represent some of the factors affecting Surgical Site Infections (SSIs). The aim of the present study was to assess the microbiological quality of operating settings and the staff compliance to the SSI evidence-based control measures. Ten operating rooms were examined for microbiological contamination of air and surfaces, after cleaning procedures, in “at rest” conditions. Furthermore, 10 surgical operations were monitored to assess staff compliance to the recommended practices. None of the air samples exceeded microbiological reference standards and only six of the 200 surface samples (3.0%) were slightly above recommended levels. Potentially pathogenic bacteria and moulds were never detected. Staff compliance to best practices varied depending on the type of behaviour investigated and the role of the operator. The major not compliant behaviours were: pre-operative skin antisepsis, crowding of the operating room and hand hygiene of the anaesthetist. The good environmental microbiological quality observed is indicative of the efficacy of the cleaning-sanitization procedures adopted. The major critical point was staff compliance to recommended practices. Awareness campaigns are therefore necessary, aimed at improving the organisation of work so as to facilitate compliance to operative protocols.
- 28 December 2017
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 15 (1) , 46
Open AccessSurveillance of Environmental and Procedural Measures of Infection Control in the Operating Theatre Setting
The microbiological contamination of operating theatres and the lack of adherence to best practices by surgical staff represent some of the factors affecting Surgical Site Infections (SSIs). The aim of the present study was to assess the microbiological quality of operating settings and the staff compliance to the SSI evidence-based control measures. Ten operating rooms were examined for microbiological contamination of air and surfaces, after cleaning procedures, in “at rest” conditions. Furthermore, 10 surgical operations were monitored to assess staff compliance to the recommended practices. None of the air samples exceeded microbiological reference standards and only six of the 200 surface samples (3.0%) were slightly above recommended levels. Potentially pathogenic bacteria and moulds were never detected. Staff compliance to best practices varied depending on the type of behaviour investigated and the role of the operator. The major not compliant behaviours were: pre-operative skin antisepsis, crowding of the operating room and hand hygiene of the anaesthetist. The good environmental microbiological quality observed is indicative of the efficacy of the cleaning-sanitization procedures adopted. The major critical point was staff compliance to recommended practices. Awareness campaigns are therefore necessary, aimed at improving the organisation of work so as to facilitate compliance to operative protocols.
- Open Access
- 10 January 2017
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 14 (1) , 61
Surveillance of Clostridium difficile Infections: Results from a Six-Year Retrospective Study in Nine Hospitals of a North Italian Local Health Authority
Clostridium difficile is an emerging cause of healthcare associated infections. In nine hospitals of an Italian Local Health Authority the episodes of C. difficile infection (CDI) were identified using the data registered by the centralized Laboratory Information System, from 2010 to 2015. CDI incidence (positive patients for A and/or B toxins per patients-days) was analysed per year, hospital, and ward. A number of cases approximately equivalent to the mean of identified cases per year were studied retrospectively to highlight the risk factors associated to CDI and their severity. Nine hundred and forty-two patients affected by CDI were identified. The overall incidence was 3.7/10,000 patients-days, with a stable trend across the six years and the highest rates observed in smaller and outlying hospitals (up to 17.8/10,000), where the admitted patients were older and the wards with the highest incidences (long-term-care: 7.6/10,000, general medicine: 5.7/10,000) were more represented. The mean age of patients in each hospital was correlated with CDI rates. Of the 101 cases selected for the retrospective study, 86.1% were healthcare associated, 10.9% community acquired; 9.1% met the criteria for recurrent case and 23.8% for severe case of CDI. The overall mortality rate was 28.7%. Comorbidity conditions occurred in 91.1%, previous exposure to antibiotics in 76.2%, and proton pump inhibitors in 77.2%. Recurrent and severe cases were significantly associated with renal insufficiency and creatinine levels ≥2 mg/dL. The survey based on the centralized laboratory data was useful to study CDI epidemiology in the different centres in order to identify possible weaknesses and plan control strategies, in particular the reinforcement of staff training, mainly targeted at compliance with contact precautions and hand hygiene.
- 10 January 2017
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 14 (1) , 61
Open AccessSurveillance of Clostridium difficile Infections: Results from a Six-Year Retrospective Study in Nine Hospitals of a North Italian Local Health Authority
Clostridium difficile is an emerging cause of healthcare associated infections. In nine hospitals of an Italian Local Health Authority the episodes of C. difficile infection (CDI) were identified using the data registered by the centralized Laboratory Information System, from 2010 to 2015. CDI incidence (positive patients for A and/or B toxins per patients-days) was analysed per year, hospital, and ward. A number of cases approximately equivalent to the mean of identified cases per year were studied retrospectively to highlight the risk factors associated to CDI and their severity. Nine hundred and forty-two patients affected by CDI were identified. The overall incidence was 3.7/10,000 patients-days, with a stable trend across the six years and the highest rates observed in smaller and outlying hospitals (up to 17.8/10,000), where the admitted patients were older and the wards with the highest incidences (long-term-care: 7.6/10,000, general medicine: 5.7/10,000) were more represented. The mean age of patients in each hospital was correlated with CDI rates. Of the 101 cases selected for the retrospective study, 86.1% were healthcare associated, 10.9% community acquired; 9.1% met the criteria for recurrent case and 23.8% for severe case of CDI. The overall mortality rate was 28.7%. Comorbidity conditions occurred in 91.1%, previous exposure to antibiotics in 76.2%, and proton pump inhibitors in 77.2%. Recurrent and severe cases were significantly associated with renal insufficiency and creatinine levels ≥2 mg/dL. The survey based on the centralized laboratory data was useful to study CDI epidemiology in the different centres in order to identify possible weaknesses and plan control strategies, in particular the reinforcement of staff training, mainly targeted at compliance with contact precautions and hand hygiene.