Zhengqi Ye
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhengqi Ye has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
Hong Gao
Drug Metabolism & Pharmacokinetics, Vertex Pharmaceuticals, Inc. Boston, MA 02210, USA
3 shared publicationsCraig Zetterberg
Drug Metabolism and Pharmacokinetics, Vertex Pharmaceuticals, Inc. 50 Northern Ave, Boston, MA 02210, USA
1 shared publicationQing Chen
Drug Metabolism & Pharmacokinetics, Vertex Pharmaceuticals, Inc., Boston, MA02210, USA
1 shared publication
Latest Publications
- 1 December 2020
- Published by Taylor & Francis in Bioanalysis
- Vol. 12 (23) , 1699-1708
Improving the accuracy of unbound fraction measurement of drug-protein binding by preconditioning the RED membrane inserts
Aim: The objective of this study was to evaluate the rapid equilibrium dialysis (RED) device in protein binding assays in diluted protein matrices and to improve the accuracy of the unbound fraction (f(u)) measurement. Methodology: Protein binding assays of drug compounds in bovine serum albumin solutions and human plasma with different folds of dilution were performed using the RED device with and without preconditioning of the dialysis membrane inserts, and the results were compared with those using other approaches in this study. Results & conclusion: Preconditioning of the RED membrane inserts improved the f(u) data accuracy of drug-protein binding assay in matrices with relatively low protein contents and such impact could be compound dependent.
- 1 December 2020
- Published by Taylor & Francis in Bioanalysis
- Vol. 12 (23) , 1699-1708
Improving the accuracy of unbound fraction measurement of drug-protein binding by preconditioning the RED membrane inserts
Aim: The objective of this study was to evaluate the rapid equilibrium dialysis (RED) device in protein binding assays in diluted protein matrices and to improve the accuracy of the unbound fraction (f(u)) measurement. Methodology: Protein binding assays of drug compounds in bovine serum albumin solutions and human plasma with different folds of dilution were performed using the RED device with and without preconditioning of the dialysis membrane inserts, and the results were compared with those using other approaches in this study. Results & conclusion: Preconditioning of the RED membrane inserts improved the f(u) data accuracy of drug-protein binding assay in matrices with relatively low protein contents and such impact could be compound dependent.
- 10 April 2018
- Published by Taylor & Francis in Bioanalysis
- Vol. 10 (7) , 451-459
Approaches to Measure Protein Binding of Enzymatically Unstable Compounds in Plasma
Aim: To develop approaches to measure plasma protein binding (PPB) of enzymatically unstable compounds. Methodology: Bis-para-nitrophenyl phosphate (BNPP) was used to inhibit enzyme activity and stabilize two model compounds (diltiazem and oseltamivir) that are subject to enzyme-catalyzed hydrolysis in plasma. Protein binding of the compounds in BNPP-treated rat plasma was measured using equilibrium dialysis or ultrafiltration. Conclusion: PPB measurement of unstable compounds was improved by using enzyme inhibitor to stabilize the compounds in plasma during the assay. The effect of BNPP concentration on drug-protein binding appeared to be compound dependent. Given the compound's nonspecific binding to the assay device can be accounted for in the unbound fraction measurement, ultrafiltration can be a viable alternative or complementary approach for PPB assay of unstable compounds while minimizing the potential impact of enzyme inhibitor on drug-protein binding.
- 10 April 2018
- Published by Taylor & Francis in Bioanalysis
- Vol. 10 (7) , 451-459
Approaches to Measure Protein Binding of Enzymatically Unstable Compounds in Plasma
Aim: To develop approaches to measure plasma protein binding (PPB) of enzymatically unstable compounds. Methodology: Bis-para-nitrophenyl phosphate (BNPP) was used to inhibit enzyme activity and stabilize two model compounds (diltiazem and oseltamivir) that are subject to enzyme-catalyzed hydrolysis in plasma. Protein binding of the compounds in BNPP-treated rat plasma was measured using equilibrium dialysis or ultrafiltration. Conclusion: PPB measurement of unstable compounds was improved by using enzyme inhibitor to stabilize the compounds in plasma during the assay. The effect of BNPP concentration on drug-protein binding appeared to be compound dependent. Given the compound's nonspecific binding to the assay device can be accounted for in the unbound fraction measurement, ultrafiltration can be a viable alternative or complementary approach for PPB assay of unstable compounds while minimizing the potential impact of enzyme inhibitor on drug-protein binding.
- 1 June 2017
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 140, 210-214
Automation of plasma protein binding assay using rapid equilibrium dialysis device and Tecan workstation
- 1 June 2017
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 140, 210-214
Automation of plasma protein binding assay using rapid equilibrium dialysis device and Tecan workstation
- 19 January 2017
- Published by Taylor & Francis in Bioanalysis
- Vol. 9 (4) , 349-357
Evaluation of Sample Extraction Methods for Minimizing Hematocrit Effect on Whole Blood Analysis with Volumetric Absorptive Microsampling
Aim: Volumetric absorptive microsampler (VAMS) was designed to sample a fixed volume of blood regardless of the hematocrit (HCT) levels. Model compounds with a wide range of hydrophobicity were evaluated for their extraction recoveries from VAMS dried blood samples. Results: For the highly hydrophobic compounds, recoveries with methanol or methanol/acetonitrile extraction were higher compared with using the aqueous mixture of methanol or acetonitrile. Extraction with methanol/acetonitrile (1:1) yielded more consistent recovery across the HCT range of 20–70% than using methanol alone, with good linearity, accuracy and precision achieved from 1 to 2000 ng/ml. Conclusion: An organic solvent sample preparation approach was developed to optimize extraction recovery and minimize the HCT effect on the analysis of VAMS dried blood samples.
- 19 January 2017
- Published by Taylor & Francis in Bioanalysis
- Vol. 9 (4) , 349-357
Evaluation of Sample Extraction Methods for Minimizing Hematocrit Effect on Whole Blood Analysis with Volumetric Absorptive Microsampling
Aim: Volumetric absorptive microsampler (VAMS) was designed to sample a fixed volume of blood regardless of the hematocrit (HCT) levels. Model compounds with a wide range of hydrophobicity were evaluated for their extraction recoveries from VAMS dried blood samples. Results: For the highly hydrophobic compounds, recoveries with methanol or methanol/acetonitrile extraction were higher compared with using the aqueous mixture of methanol or acetonitrile. Extraction with methanol/acetonitrile (1:1) yielded more consistent recovery across the HCT range of 20–70% than using methanol alone, with good linearity, accuracy and precision achieved from 1 to 2000 ng/ml. Conclusion: An organic solvent sample preparation approach was developed to optimize extraction recovery and minimize the HCT effect on the analysis of VAMS dried blood samples.